Phoenix QUINT-UPS/ 24DC/ 24DC/10/3.4AH-Uninterruptible power supply 2320267, uninterruptible power supply with IQ Technology and built-in battery, for DIN rail installation, input: 24V DC, output: 24V DC/10 A, battery: leaded AGM 4 Ah, including installed universal DIN rail adapter UTA 107/30
| DC operation | |
| input voltage | 24V DC |
| Input Voltage Range | 18V DC ... 30V DC |
| DC input voltage range | 18V DC ... 30V DC |
| Supply Voltage | DC |
| buffer time | 180 min (1 A) |
| 10 min (10 A) | |
| power consumption | 18.6 A (24V DC) |
| 9.5 mA | |
| 3.6 A | |
| 14 A | |
| efficiency | > 97.6 % (mains operation, with charging power storage device) |
| 96.41 percent | |
| Rated output voltage | 24V DC |
| Output Voltage Range | 18V DC ... 30V DC |
| Rated output current (IN) | 10 A (0°C ... 40 °C) |
| Output Current Limit | > 15 A (battery operated) |
| bridge time | 600 s |
| Attenuation | 60°C ... 70°C (2.5 %/K) |
| output power | 240W |
| power consumption | 3.1W (main line operation) |
| 3.19W (main line operation) | |
| 1.8W (main line operation) | |
| 6.3W (battery operated) | |
| 4W (battery operated) | |
| 5.1W (battery operated) | |
| output fuse | 1x 25 A |
| Parallel | 2 |
| Concatenation | No |
| mains power supply | |
| Rated output voltage | 24V DC |
| Output Voltage Range | 18V DC ... 30V DC (UOUT= UIN- 0,1V DC) |
| Rated output current (IN) | 10 A (0°C ... 40 °C) |
| POWER BOOST (IBoost) | 15 A (0°C ... 40 °C) |
| selective fusing (ISFB) | 60 A (0°C ... 40 °C) |
| cycle | 12 ms (SFB technology) |
| battery operation | |
| Rated output voltage | 24V DC |
| Output Voltage Range | 19.2V DC ... 27.6V DC (UOUT= UBAT- 0,5V DC) |
| Rated output current (IN) | 10 A (0°C ... 40 °C) |
| POWER BOOST (IBoost) | 15 A (0°C ... 40 °C) |
| selective fusing (ISFB) | 65 A (0°C ... 40 °C) |
| cycle | 15 ms (SFB technology) |
| signal: alarm | |
| Output Description | relay |
| output voltage | ≤ 30V AC/DC |
| Continuous load current | ≤ 100 mA |
| signal: battery charging | |
| Output Description | relay |
| output voltage | ≤ 30V AC/DC |
| Continuous load current | ≤ 100 mA |
| signal: battery mode | |
| Output Description | relay |
| output voltage | ≤ 30V AC/DC |
| Continuous load current | ≤ 100 mA |
| signal | |
| Continuous load current | ≤ 200 mA |
| Rated voltage UN | 24V DC |
| end of charging | 24V DC ... 29V DC (temperature compensated) |
| charging current | 1.2 A |
| Rated capacity | 4 Ah |
| buffer time | 180 min (1 A) |
| 10 min (10 A) | |
| battery module life | 6 years... 9 years (20°C) |
| Maximum commissioning interval (battery only) | (0°C ... 20°C) |
| Last Debug (Battery Only)-Range | (20°C ... 30°C) |
| (30°C ... 40°C) | |
| battery technology | VRLA-AGM |
| storage media | VRLA-AGM Battery 4.0 Ah |
| Accumulator Type | 2x BB Battery HR4.2-12FR (from UPS V/C-level 06) |
| IQ Technology | is |
| temperature sensor: | is |
| Network Management | is |
Phoenix QUINT-UPS/ 24DC/ 24DC/10/3.4AH-Uninterruptible Power Supply 2320267
Created on:2025-02-10 14:41