Phoenix ST 4-HESILED 24 (5X20) -fuse terminal 3036547, fuse terminal, fuse type: glass/ceramic/ ..., fuse type: G / 5 x 20, nominal working voltage: 24V, rated current: 6.3 A, wiring method: pull-back spring connection, first layer, rated wiring capacity: 1mm2, wiring capacity: 0.08 mm2 -6mm2, installation method: NS 35/7,5, NS 35/15, color: black

Product Type Fuse Terminal
connection quantity 2
Rows 1
potential 1
insulation characteristics
Overvoltage Category III
pollution level 3

Fuse Type glass/ceramic/ ...
Rated surge voltage 4 kV
rated conditions 1.02W
Fuse G / 5 x 20
LED voltage range 12V AC/DC ... 30V AC/DC
LED current range 0.31 mA ... 0.95 mA
maximum power loss Maximum 1.6W (single-row fuse terminal, providing protection in the event of overload)
Maximum 1.6W (multiple fuse terminals are connected to each other to provide protection in the event of overload)
Maximum 4W (single-row fuse terminal, providing protection in the event of a short circuit)
Maximum 2.5W (multiple fuse terminals are connected to each other to provide protection in the event of a short circuit)

LED voltage range 12V AC/DC ... 30V AC/DC

the number of connections per layer 2
Rated cross section 4 mm²
first layer
stripping length 8mm ... 10mm
plug gauge A4
connection meets standards IEC 60947-7-3
Rigid conductor cross section 0.08 mm² ... 6 mm²
cross-section AWG 28 ... 10 (as amended by IEC standards)
Flexible Wire Cross Section 0.08 mm² ... 4 mm²
WIRE CROSS SECTION, FLEXIBLE [AWG] 28 ... 12 (as amended by IEC standards)
Flexible conductor cross-section (sleeve without plastic insulation) 0.14 mm² ... 4 mm²
flexible conductor cross-section (sleeve with plastic insulating tube) 0.14 mm² ... 4 mm²
2 wires with the same cross section, flexible, with TWIN sleeve and plastic sleeve 0.5 mm² ... 1 mm²
Nominal current 6.3 A
Maximum load current 6.3 A (current depends on the fuse used)
Rated voltage 24V
Rated cross section 1 mm²

width 6.2mm
height 61.5mm
NS 35/7,5 depth 62.5mm
NS 35/15 Depth 70mm

color black (RAL 9005)
flame retardant rating, according to UL 94 V0
Insulation Material Group I
insulation material PA
Application of Static Insulation Materials at Low Temperature -60°C
insulating materials (DIN EN 60216-1(VDE 0304-21)) 130°C
Insulation Relative Temperature Index (Electrical, UL 746 B) 130°C
railway vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection of railway vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
railway vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection of railway vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Thermal Release NFPA 130 (ASTM E 1354) 28 MJ/kg
Surface Flammability NFPA 130 (ASTM E 162) through
Smoke specific optical density NFPA 130 (ASTM E 662) through
Smoke Toxicity NFPA 130 (SMP 800C) through

Phoenix ST 4-HESILED 24 (5X20) -Fuse Terminal Block 3036547