Phoenix PT 2X1-VF-230AC-surge protector 2805460, rail-mounted surge protector, used for high-voltage signal protection. The protection circuit has no leakage current and is used to protect 2 floating ground signals. Rated voltage: 230VAC
| Product Type | measurement and control technology |
| Product Series | PLUGTRAB PT |
| IEC Category | C1 |
| C2 | |
| C3 | |
| D1 | |
| type | DIN rail module, split, detachable |
| Bits | 2 |
| Rated voltage UN | 230V AC |
| indicator/remote signaling | |
| switching function | normally closed contact |
| Maximum operating voltage Umax.AC | 250V AC |
| Maximum operating current Imax | 1 A |
| Connection Mode | screw connection |
| thread | M3 |
| Tightening torque | 0.8 Nm |
| Flexible Wire Cross Section | 0.2 mm² ... 2.5 mm² |
| Rigid conductor cross section | 0.2 mm² ... 4 mm² |
| Connectable Guide Cross Section AWG | 24 ... 12 |
| Dimensional drawing | |
| width | 17.7mm |
| height | 90mm |
| depth | 51.7mm |
| Horizontal stitch pitch | 1 Partition |
| full module width | 17.7mm |
| Full module height | 90mm |
| full module depth | 65.5mm |
| color | black (RAL 9005) |
| flame retardant rating, according to UL 94 | V-0 |
| Shell Material | PA 6.6 |
| Mechanical parameters | |
| Open Side Panel | No |
| movement direction | Line-Line & Line-Earth Ground |
| Maximum continuous voltage Uc | 250V AC |
| Rated current | 6 A |
| UC, the effective working current IC | ≤ 2 µA |
| Residual Flow IPE | ≤ 2 µA (UN) |
| Nominal discharge current In(8/20) µs | 3 kA |
| Rated discharge current In(8/20)& micro;s (core-ground) | 3 kA |
| pulse discharge current Iimp(10/350) µs | 500 A |
| Total discharge current Itotal(8/20) µs | 8 kA |
| Total discharge current Itotal(10/350) µs | 1 kA |
| Maximum discharge current Imax(8/20)µs | 8 kA |
| Maximum discharge current Imax(8/20) & micro;s (core-ground) | 8 kA |
| rated power pulse current lan (1000)& micro;s (core-ground) | 100 A |
| Output voltage limit 1 kV/& micro;s (core-ground) static | ≤ 1.4 kV |
| Residual voltage ln,(wire-wire) | ≤ 2 kV |
| Residual voltage ln,(wire-ground) | ≤ 1 kV |
| Residual voltage lan(10/1000)& micro;s (wire-wire) | ≤ 1.4 kV |
| Ian(10/1000)& micro; Residual pressure at s (line-ground) | ≤ 700V |
| Maximum absorbed energy (2 ms) | 150 J |
| voltage protection level Up(core-core) | ≤ 2.5 kV (C2 - 4 kV / 2 kA) |
| ≤ 1.8 kV (C3 - 100 A) | |
| ≤ 2.6 kV (D1 - 500 A) | |
| voltage protection level Up(Line-Ground) | ≤ 1.1 kV (C1 - 500 A) |
| ≤ 1.5 kV (C2 - 4 kV / 2 kA) | |
| ≤ 1.6 kV (C3 - 100 A) | |
| ≤ 1.8 kV (D1 - 500 A) | |
| response time tA | ≤ 100 ns |
| capacitance (core-core) | Typical 4.5 pF |
| capacitance (core-ground) | Typical 9 pF |
| the resistance of each path | 0 Ω |
| Surge protection fault alarm | None |
| 6 A (gL/gG) | |
| Impact resistance (line-ground) | C2 - 4 kV / 2 kA |
| C3 - 100 A | |
| D1 - 500 A |
Phoenix PT 2X1-VF-230AC-Surge Protector 2805460
Created on:2025-02-17 15:12