Phoenix USLKG 6 N-Ground Terminal 0442079, Ground Terminal, Connection Quantity: 2, Connection Mode: Screw Connection, Cross Section: 0.2 mm2 -10mm2, Installation Mode: PE Foot and Mounting Screw, M4, Installation Mode: NS 35/7,5, NS 35/15, NS 32, Color: Yellow and Green
Product Type |
Ground terminal |
connection quantity |
2 |
Rows |
1 |
insulation characteristics |
Overvoltage Category |
III |
pollution level |
3 |
Rated surge voltage |
8 kV |
rated conditions |
1.31W |
the number of connections per layer |
2 |
Rated cross section |
6 mm² |
Layer 1 Upper 1 Lower 1 |
thread |
M4 |
Considerations |
Note the ampacity of the DIN rail. |
Tightening torque |
1.5 ... 1.8 Nm |
stripping length |
10mm |
plug gauge |
A5 |
connection meets standards |
IEC 60947-7-2 |
Rigid conductor cross section |
0.2 mm² ... 10 mm² |
cross-section AWG |
24 ... 8 (as amended by IEC standards) |
Flexible Wire Cross Section |
0.2 mm² ... 6 mm² |
WIRE CROSS SECTION, FLEXIBLE [AWG] |
24 ... 10 (as amended by IEC standards) |
Flexible conductor cross-section (sleeve without plastic insulation) |
0.25 mm² ... 6 mm² |
flexible conductor cross-section (sleeve with plastic insulating tube) |
0.25 mm² ... 6 mm² |
rated parameters (ATEX/IECEx) |
identification |
II 2 GD Ex eb IIC |
Operating temperature range |
-60°C ... 110°C |
Ex Certified Accessories |
1205066 SZS 1,0X4,0 VDE |
1201442 E/UK |
PE connecting feet |
1.5 Nm ... 1.8 Nm |
Output |
(permanent) |
Ex Connection Data Overview |
Torque range |
1.5 Nm ... 1.8 Nm |
Rated cross section |
6 mm² |
Rated wiring capacity AWG |
10 |
Rigid Wiring Capacity |
0.2 mm² ... 10 mm² |
Wiring capacity AWG |
24 ... 8 |
flexible wiring capacity |
0.2 mm² ... 6 mm² |
Wiring capacity AWG |
24 ... 10 |
width |
8.2mm |
height |
42.5mm |
depth |
45.8mm |
NS 32 Depth |
52mm |
NS 35/7,5 depth |
47mm |
NS 35/15 Depth |
54.5mm |
color |
green and yellow |
flame retardant rating, according to UL 94 |
V0 |
Insulation Material Group |
I |
insulation material |
PA |
Application of Static Insulation Materials at Low Temperature |
-60°C |
Insulation Relative Temperature Index (Electrical, UL 746 B) |
130°C |
railway vehicles (DIN EN 45545-2) R22 |
HL 1 - HL 3 |
Fire protection of railway vehicles (DIN EN 45545-2) R23 |
HL 1 - HL 3 |
railway vehicles (DIN EN 45545-2) R24 |
HL 1 - HL 3 |
Fire protection of railway vehicles (DIN EN 45545-2) R26 |
HL 1 - HL 3 |
Surface Flammability NFPA 130 (ASTM E 162) |
through |
Smoke specific optical density NFPA 130 (ASTM E 662) |
through |
Smoke Toxicity NFPA 130 (SMP 800C) |
through |