Phoenix SAC-3P-1,5-PUR/A-1L-R-sensor/actuator cable 1400589, sensor/actuator cable, 3-position, PUR halogen-free, black-gray RAL 7021, free outlet, with valve connector A, with 1 LED lamp, wiring: freewheeling diode, cable length: 1.5 m
| Product Type |
cable with plug-in valve |
| Application |
standard |
| Bits |
3 |
| Outlet No. |
1 |
| Shielding |
None |
| insulation characteristics |
| Overvoltage Category |
III |
| pollution level |
3 |
| Wire Connection |
| Tightening torque |
0.6 Nm (valve plug) |
| flame retardant rating, according to UL 94 |
V0 |
| sealing material |
TPU |
| material shell solenoid valve plug |
TPU |
| Contact Material |
CuSn |
| ferrule material of solenoid valve plug |
PA 6.6 |
| Contact Surface Material |
Sn |
| insulation resistance |
≥ 100 MΩ |
| Rated voltage UN |
24V DC |
| Rated current IN |
2 A |
| Status Display |
1 LED light |
| Status Display |
have |
| connection 1 |
| type |
Free Outlet |
| Connection 2 |
| type |
Valve Connector A |
| Bits |
3 |
| Identification Materials |
CuSn (contact) |
| Sn (contact surface) |
| PA 6.6 (ferrule) |
| TPU (housing) |
| protection circuit |
freewheeling diode |
| Cable Length |
1.5 m |
| Halogen-free PUR Black [PUR] |
| Dimensional drawing |
|
| Cable Weight |
30 kg/km |
| UL AWM |
20549 |
| Bits |
3 |
| Shielding |
None |
| Cable Type |
Halogen-free PUR Black [PUR] |
| wire structure signal line |
28x 0.15mm |
| AWG, signal wire |
20 |
| Wire Cross Section |
3x 0.5 mm² |
| wire diameter, including insulation |
1.5mm ± 0.05mm (signal line) |
| Cable outer diameter |
4.50mm ± 0.2mm |
| outer sheath, material |
PUR |
| outer sheath, color |
Black-Grey RAL 7021 |
| Wire Material |
copper stranded wire |
| wire insulation material |
PP |
| single line, color |
black 1, black 2, yellow and green |
| Total Strand |
3 wire, stranded |
| Maximum conductor resistance |
39 Ω/km (at 20°C) |
| insulation resistance |
20 MΩ * km minimum |
| Rated voltage, cable |
≤ 300V |
| Test Voltage |
≥ 1200V |
| minimum bending radius, fixed installation |
5 x D |
| minimum bending radius, movable installation |
10 x D |
| minimum bending radius, fixed mounting |
22.5mm |
| minimum bending radius, mobile installation |
45mm |
| Dynamic Load Capacity (Bending) |
Maximum bending times: 150000, Bending radius: 50mm, Transverse trajectory: 0.9 m, Transverse speed: 5 m/s, Acceleration: 30 m/s |
| Halogen-free |
according to DIN VDE 0472 Chapter 815 |
| flame retardant |
Complies with DIN VDE 0482 |
| according to DIN EN 50265-2-1 |
| oil resistance |
according to DIN EN 60811-2-1 |
| Other protective functions |
main oil resistance |
| partially UV resistant (according to DIN EN ISO 4892-2-A) |
| ambient temperature (operation) |
-40°C ... 80°C (cable, fixed installation) |
| -20°C ... 80°C (cable, movable installation) |