Phoenix SAC-2P-MSB/15,0-910 SCO-Bus Cable 1518054, Bus Cable, PROFIBUS (12 Mbps),2-Position, PUR Halogen-Free, Purple RAL 4001, Shielded, Plug Straight M12 SPEEDCON, Code: B, With Free Outlet, Cable Length: 15 m
Product Type
Pre-installed data cable
Application
standard
Sensor Type
PROFIBUS
Bits
2
Outlet No.
1
Shielding
have
coding
B
insulation characteristics
Overvoltage Category
II
pollution level
3
Interface
bus system
PROFIBUS
Signal Type/Classification
PROFIBUS, 12 Mbps (up to 100 m)
signal processing
Status Display
None
Status Display
No
Electrical characteristics
insulation resistance
≥ 100 MΩ
Rated voltage UN
48V AC
60V DC
Rated current IN
4 A
transmission medium
copper cable
Material Specification
Fixture body material
TPU, high flame retardancy, with self-extinguishing properties
Contact Material
CuSn
Material Contact Surface
Ni/Au
Contact Carrier Material
TPU GF
screw connection material
zinc cast, nickel plated
connection data
Pin Allocation
contacts | color (signal indication) | contacts (optional)
2 (SPD-plug) | GN (A cable)
4 (SPD-plug) | RD (B cable)
Connector
connection 1
type
plug straight head M12 SPEEDCON
Bits
2
Lock Type
SPEEDCON
Error-proofing code type
B (Reverse)
Connection 2
Model
Free Outlet
cable/wire
Cable Length
15 m
PROFIBUS [910]
Dimensional drawing
Cable Weight
90 kg/km
UL AWM
21198 (80°C/300 V)
Bits
2
Shielding
have
Cable Type
PROFIBUS [910]
Wire Structure
1 x2xAWG24/19
wire structure signal line
19x 0.13mm
AWG, signal wire
24
Wire Cross Section
2x 0.25 mm² (signal line)
wire diameter, including insulation
2.55mm ± 0.07mm
Cable outer diameter
7.80mm ± 0.2mm
outer sheath, material
PUR
outer sheath, color
Purple RAL 4001
Wire Material
tinned copper stranded wire
Filling layer material
PP
wire insulation material
Foam-Skin PP
single line, color
red, green
Total Strand
2 strands twisted on respective filler cores
Cable Shielding Cover
85%
Maximum conductor resistance
≤ 78.6 Ω/km
insulation resistance
≥ 5 GΩ*km
wave impedance
150 Ω ±10 % (3 MHz ... 20 MHz)
Cable Capacity
rated 30 pF/m
Rated voltage, cable
300V
Core test voltage/core
1500V (50 Hz,1 min)
Core Test Voltage/Shielding
1500.00V (50 Hz,1 min)
minimum bending radius, fixed mounting
40mm
minimum bending radius, mobile installation
65mm
Dynamic Load Capacity (Bending)
Maximum bending times: 400000, Bending radius: 65mm, Lateral trajectory: 4.5 m, Lateral speed: 3 m/s, Acceleration: 3 m/s, Ambient temperature: -20°C ... 60°C
Maximum number of bends: 5000000, Bending radius: 80mm, Lateral trajectory: 4.5 m, Lateral speed: 3 m/s, Acceleration: 3 m/s ², Ambient temperature: -20°C ... 60°C
Shielding Attenuation
≤ 0.049 dB/m (16 MHz)
Halogen-free
according to DIN VDE 0472 Chapter 815
conforming to IEC 60754-1