Phoenix SAC-5P- 2,0-900/FSB SCO-Bus Cable 1517916, Bus Cable, INTERBUS (16 Mbps),5-Position, PUR Halogen-Free, Bean Green RAL 6017, Shielded, Free Outlet, SPEEDCON with Hole Type Straight M12, Code: B, Cable Length: 2 m

Product Type Pre-installed data cable
Application standard
Sensor Type INTERBUS
Bits 5
Outlet No. 1
Shielding have
coding B
insulation characteristics
Overvoltage Category II
pollution level 3

bus system INTERBUS
Signal Type/Classification INTERBUS, 16 Mbps

Status Display None
Status Display No

insulation resistance ≥ 100 MΩ
Rated voltage UN 48V AC
60V DC
Rated current IN 4 A
transmission medium copper cable

flame retardant rating, according to UL 94 V0
sealing material NBR
Fixture body material TPU, high flame retardancy, with self-extinguishing properties
Contact Material CuSn
Material Contact Surface Ni/Au
Contact Carrier Material PA 6.6
screw connection material zinc cast, nickel plated

Pin Position Assignment
Contacts | Color (signal indication) | Contacts (optional) 1 (Hole Plug) | YE (DO)
2 (Hole Plug) | GN (DO)
3 (Hole Plug) | GY (DI)
4 (hole plug) | PK (DI)
5 (hole plug) | BN (GND)

connection 1
type Free Outlet
Connection 2
Model Free Outlet

Cable Length 2 m
INTERBUS [900]
Dimensional drawing
Cable Weight 70 kg/km
Bits 6
Shielding have
Cable Type INTERBUS [900]
Wire Structure 3 x 2 x 0.22 mm²
Signal Speed 0.66 c
wire structure signal line 32x 0.10mm
AWG, signal wire 24
Wire Cross Section 3x 2x 0.22 mm²
Cable outer diameter 8.00mm
outer sheath, material PUR
outer sheath, color Bean Green RAL 6017
Wire Material copper stranded wire
wire insulation material PE
single line, color green-yellow, white-brown, gray-pink
Twisted Pair 2 wires as a pair
Total Strand 3 twisted pairs intertwined
insulation resistance ≥ 5 GΩ*km
coupling resistance < 250.00 mΩ/m (30 MHz)
Loop Resistance ≤ 159.80 Ω/km
wave impedance 120 Ω ±20 % (64 kHz)
100 Ω ±15 % (1 MHz)
Cable Capacity ≤ 60 nF/km (800 Hz)
Rated voltage, cable 250V (peak, not suitable for high power applications)
Core test voltage/core 1500Vrms
Core Test Voltage/Shielding 1000.00Vrms
minimum bending radius, fixed installation 7,5 x D
minimum bending radius, movable installation 15 x D
minimum bending radius, fixed mounting 60mm
minimum bending radius, mobile installation 120mm
Dynamic Load Capacity (Bending) Maximum bending times: 5000000, bending radius: 120mm, transverse trajectory: 10 m, transverse speed: 1.6 m/s, acceleration: 3.2 m/s ²