Phoenix ELR H5-IES-PT-24DC/500AC-06-T-Hybrid Motor Starter 2906058, Hybrid Motor Starter; Functions: starting motor, reverse motor, motor protection (grade 10A), emergency stop button, higher transient voltage tolerance, ATEX; Input: 24V DC; Output: 3 ~, 500V AC, 600 mA; In-line connection
| Product Type | hybrid motor starter |
| Product Series | CONTACTRON |
| Mode of operation | 100% operating factor |
| phase number | 3 |
| Motor Starter Type | reversible starter |
| Switching frequency | ≤ 2Hz (depending on load) |
| rated conditions | 0.4W |
| Switching frequency | ≤ 2Hz (depending on load) |
| maximum power loss | 1.5W |
| minimum power loss | 1.1W |
| type of coordination | 1 |
| Power | |
| Rated control circuit supply voltage US | 24V DC |
| Control Supply Voltage Range | 19.2V DC ... 30V DC |
| Rated control supply current IS | 40 mA |
| protection circuit | surge protection |
| polarity protection | |
| insulation characteristics | |
| Rated insulation voltage | 500V |
| Rated overvoltage | 6 kV |
| Overvoltage Level | III |
| pollution level | 2 |
| control input and control supply voltage and insulation characteristics from auxiliary circuit to main circuit | safety insulation (IEC 60947-1/EN 50178) for operating voltages ≤ 300V AC |
| operating voltage 300V AC ... 500V AC (IEC 60947-1) | |
| safety insulation (EN 50178), suitable for working voltage 300 ... 500V AC | |
| control input and control supply voltage to auxiliary circuits | safety insulation (IEC 60947-1),≤ 300V AC in auxiliary circuits |
| safety insulation (EN 50178), in auxiliary circuits ≤ 300V AC | |
| control | |
| Enter Name | Control Input Right/Left |
| Rated operating voltage UC | 24V DC |
| Trigger voltage range | 19.2V DC ... 30V DC |
| Rated operating current IC | 5 mA |
| Switch Threshold | 9.6V ("0" signal) |
| 19.2V ("1" signal) | |
| switch level | < 5V DC (for emergency stop) |
| Typical closing time | < 30 ms |
| protection circuit | polarity protection |
| AC output | |
| Rated operating voltage Ue | 500V AC |
| Operating voltage range | 42V AC ... 550V AC |
| Rated operating current Ie | 0.6 A (AC-51) |
| 0.6 A (AC-53a) | |
| mains frequency | 50/60Hz |
| Load current range | 75 mA ... 600 mA (see attenuation curve) |
| action characteristics according to IEC 60947-4-2 | Class 10A |
| cooling time | 20 min |
| leakage current | 0 mA |
| protection circuit | surge protection |
| Confirm Output | |
| Considerations | confirmation: floating transfer contact, signal contact |
| Contact Type | 1 changeover contact |
| switching capacity according to IEC 60947-5-1 | 3 A (230 V, AC15) |
| 2 A (24V (DC13)) | |
| control loop | |
| Connection Mode | in-line connection |
| stripping length | 10mm |
| Rigid conductor cross section | 0.2 mm² ... 2.5 mm² |
| Flexible Wire Cross Section | 0.2 mm² ... 2.5 mm² |
| Attachable Guide Cross Section AWG | 24 ... 14 |
| Load Circuit | |
| Connection Mode | in-line connection |
| stripping length | 10mm |
| Rigid conductor cross section | 0.2 mm² ... 2.5 mm² |
| Flexible Wire Cross Section | 0.2 mm² ... 2.5 mm² |
| Attachable Guide Cross Section AWG | 24 ... 14 |
| Status Display | LED (yellow) |
| Operating voltage display | Green LED |
| error indication | Red LED |
| width | 22.5mm |
| height | 107.5mm |
| depth | 114mm |
Phoenix ELR H5-IES-PT-24DC/500AC-06-T-Hybrid Motor Starter 2906058