Phoenix PSR-SCP- 24DC/ESP4/2X1/1X2-Safety relay 2981020, safety relay, suitable for SIL 3 high-demand and low-demand applications, certified by EN 50156, DNV and EN ISO 13849 standards, used for emergency stop And safety door monitoring, single channel, 2 active current paths, 1 signal contact, plug-in screw terminal, width: 22.5mm

Product Type safety relay
Product Series PSRclassic
Application Emergency stop button
Process Technology
safety door
control single channel
mechanical life about 107Switch Times
Relay Model Electromechanical relay with mechanical interlocking contacts according to IEC/EN 61810-3
insulation characteristics
Overvoltage Level III
pollution level 2
Typical Response Time typical 60 ms (for UsManual Controlled Start)
60 ms (for Usauto start)
Typical startup time (Us) 60 ms (at Us/as required, via A1)
Typical release time Typical 20 ms (at Us/as required, via A1)
restart time < 1 s (start-up time)
Recovery Time ≥ 1 s (meet the requirements of safety function)
Start Pulse Length ≥ 500 ms (manual reset)

rated conditions 16.12W (US= 26.4V, IL² = 72 A²,PTotal Maximum= 1.72W +14.4 W)
Rated operating mode 100% Eligible
Rated insulation voltage 250V
rated overvoltage/insulation see section "Insulation Coordination" in the data sheet.

digital quantity: logic (A1)
Input Description safety related
Input Quantity 1
input voltage range, "1" signal 20.4V ... 26.4V
Impulse current max. 1 A (typical value is US,&Delta;t = < 10 ms)
filter time max. 3 ms (test pulse width of low test pulse)
200 ms minimum (test pulse rate for low test pulses)
does not allow brightness test pulse/high test pulse.
Allowable total conductor resistance 50 Ω
protection circuit Suppressor Diode
power consumption 65 mA (in UStypical)
digital quantity: starting circuit (Y2)
Input Description non-safety related
Input Quantity 1
input voltage range, "1" signal 20.4V ... 26.4V
Impulse current < 14 mA (typical value is U when Y2S,&Delta;t - 10 ms)
filter time Test pulse not allowed
Allowable total conductor resistance 50 Ω
protection circuit Suppressor Diode
power consumption 0 mA (typical value is U when Y2S)

relay: enable current path (13/14, 23/24)
Output Description 2 normally open contacts each in series, safety-related, floating
outputs 2
Contact Type 2 normally open safety contact outputs
Contact Material AgSnO2
Switching voltage minimum 10V
Max. 250V AC/DC
On-Off Capacity 100 mW minimum
Impulse current 10 mA minimum
max. 6 A
limit continuous current 6 A (note attenuation and load limit curves)
the square of the total current value 72 A2(pay attention to capacity reduction)
Switching frequency max. 0.5Hz
mechanical life 107Switch Times
output fuse 10 A gL/gG
4 A gL/gG (for low-demand applications)
Relays: Signal Transmission Current Path (31/32)
Output Description 2 parallel normally closed contacts, non-safety related, floating
outputs 1
Contact Type 1 signal transmission current path
Contact Material AgSnO2
Switching voltage 10V AC/DC minimum
Max. 250V AC/DC
On-Off Capacity 100 mW minimum
Impulse current 10 mA minimum
max. 6 A
limit continuous current 6 A

Phoenix PSR-SCP- 24DC/ESP4/2X1/1X2-Safety Relay 2981020