Phoenix PSR-SCP- 24UC/ESA4/2X1/1X2-safety relay 2963750, safety relay, used for emergency stop and safety door monitoring, safety level up to EN ISO 13849 standard SIL 3 or Cat. 4, PL e, dual channel operation, 2 enable current paths, rated input voltage: 24V DC, plug-in screw terminal

Product Type safety relay
Product Series PSRclassic
Application Emergency stop button
safety door
control dual channel
mechanical life about 107Switch Times
Relay Model Electromechanical relay with mechanical interlocking contacts according to IEC/EN 61810-3
insulation characteristics
Overvoltage Level III
pollution level 2

rated conditions 16.44W (US= 26.4 V, IL² = 72 A²,PTotal max= 2.04W +14.4 W)
Rated operating mode 100% Eligible
Rated insulation voltage 250V
rated overvoltage/insulation see section "Insulation Coordination" in the data sheet.

Overview
Rated control circuit supply voltage US 24V DC -15 % / +10%
US Typical 1.68W (DC)
Rated control supply current IS Typical 70 mA
to UNas reference 0.85 ... 1.1
UN 70 mA DC (at Us)
Impulse current < 3.5 A (&Delta;t = 3 ms Us)
< 100 mA (&Delta;t = 500 ms,Us/Ix)
> -100 mA (&Delta;t = 300 ms,Us/Ix)
< 6 mA (Us/Ixto S34)
power consumption Typical 38 mA (S12)
Typical -38 mA (S22)
typical value 1 mA (Us/Ixto S34)
input/start and feedback circuit voltage approx. 24V DC
filter time 5 ms (at A1, at the voltage dip Us)
Test pulse not allowed
Typical Response Time 150 ms (auto start)
Typical startup time (Us) 250 ms (when controlled by A1, there is us)
Typical release time 20 ms (via sensor loop as required)
45 ms (via A1 as required)
parallel
Recovery Time 1 s (in accordance with the requirements of safety functions)
< 1 s (start-up time)
protection circuit Surge protection; Suppressor diode
Allowable total conductor resistance approx. 50 Ω (US)
Operating voltage display Green LED
Status Display LED (green)

Contact Type 2 normally open safety contact outputs
1 signal transmission current path
Contact Material AgSnO2,+ 0.2 &micro;m Au
maximum switching voltage 250V AC/DC
Minimum Switching Voltage 10V AC/DC
limit continuous current 6 A (N/O contact)
Maximum impact current 6 A
Minimum impulse current 10 mA
the square of the total current value 72 A2(normally open safety contact output)
36 A2(signal current path 31/32)
Maximum power rating (resistive load) See Load Limit Curve
Minimum on-off capacity 100 mW
output fuse 10 A gL/gG (normally open safety contact output)
4 A gL/gG (Low Demand Enable Current Path)
6 A gL/gG (signal transmission current path)

connection technology
pluggable is
Wire Connection
Connection Mode screw connection
Rigid conductor cross section 0.2 mm² ... 2.5 mm²
Flexible Wire Cross Section 0.2 mm² ... 2.5 mm²
Wire Cross Section AWG 24 ... 12
stripping length 7mm
thread M3

width 22.5mm
height 99mm
depth 114.5mm

Phoenix PSR-SCP- 24UC/ESA4/2X1/1X2-Safety Relay 2963750