Phoenix PSR-SCP-24UC/CE1/3X1/1X2/B-safety relay 1046360, safety relay, used for emergency stop and safety door monitoring, safety level up to EN ISO 13849 standard SIL 3 or Cat. 4, PL e, dual Channel operation, 3 active current paths, rated input voltage: 24V DC, plug-in screw terminal

Product Type safety relay
product series PSRclassic
Application Emergency stop button
safety door
kit includes 1051297 PSR-SCP-24UC/CE1/3X1/1X2/ B SET
control dual channel
mechanical life about 107Switch Times
Relay Model Electromechanical relay with mechanical interlocking contacts according to IEC/EN 61810-3
insulation characteristics
Overvoltage Level III
pollution level 2
Typical Response Time typical 150 ms (for Usauto start)
Typical startup time (Us) Typical 250 ms (with Us/via A1 control)
Typical release time Typical 20 ms (at Us, as required, via sensor loop)
Typical 45 ms (at Us/as required, via A1)

rated conditions 16.44W (US= 26.4 V, IL² = 72 A²,PTotal max= 2.04W +14.4 W)
Rated operating mode 100% Eligible
Rated insulation voltage 250V
rated overvoltage/insulation see section "Insulation Coordination" in the data sheet.
power supply
Rated control circuit supply voltage US 24V DC -15 % / +10%
Rated control supply current IS typical value 70 mA (US)
US Typical 1.68W
Impulse current < 3.5 A (the voltage is usually US,&Delta;t = 3 ms)
filter time 5 ms (Usvoltage dips)
protection circuit series protection to prevent polarity reversal; suppression diode

digital quantity: logic (S12,S22)
Input Description safety related
Input Quantity 2
input voltage range, "0" signal 0V DC ... 5V DC (S12)
input voltage range, "1" signal 20.4V ... 26.4V (S12)
Input current range "0" signal 0 mA ... 2 mA
Impulse current < 100 mA (S12 input, voltage is usually US)
> -100 mA (S22 input, voltage is usually US)
filter time Test pulse not allowed
parallel
Allowable Total Conductor Resistance 50 Ω
protection circuit suppression diode
power consumption 38 mA (S12 input, the voltage is usually US)
-38 mA (S22 input, voltage is usually US)
digital quantity: starting circuit (S34)
Input Description non-safety related
Input Quantity 1
input voltage range, "1" signal 20.4V ... 26.4V
Impulse current < 6 mA (in UStypical)
filter time Test pulse not allowed
Allowable Total Conductor Resistance 50 Ω
protection circuit suppression diode
power consumption 1 mA (in UStypical)

relay: enable current path (13/14,23/24,33/34)
Output Description 2 normally open contacts in series, safety-related, floating
outputs 3
Contact Type 3 normally open safety contact outputs
Contact Material AgSnO2
Switching voltage Minimum 10V AC/DC
Max. 250V AC/DC
on-off capacity 100 mW minimum
Impulse current 10 mA minimum
max. 6 A
limit continuous current 6 A (pay attention to capacity reduction)
the square of the total current value 72 A2(pay attention to capacity reduction)
Switching frequency max. 0.5Hz
Maximum power rating (resistive load) attention to attenuation and load limit curves
output fuse 10 A gL/gG (high demand)
4 A gL/gG (low requirement)
Relays: Signal Transmission Current Path (41/42)
Output Description 2 parallel normally closed contacts, non-safety related, floating
outputs 1
Contact Type 1 signal transmission current path

Phoenix PSR-SCP-24UC/CE1/3X1/1X2/B-Safety Relay 1046360

Created on:2025-06-27 09:44

News Dynamics

NEWS