Phoenix RIF-1-RPT-LDP-24DC/2X21AU-relay module 2903330, a prefabricated relay module with in-line connection, including: relay base, multi-layer contact relay, plug-in display/interference suppression module and fixed bracket. Contact switching type: 2 changeover contacts. Input voltage: 24V DC

Product Type Relay Module
Product Series RIFLINE complete
Application General
Mode of operation 100% operating factor
mechanical life approx. 3x 107times
insulation characteristics
insulation input and output
changeover contacts
Overvoltage Category III
pollution level 2
Data Management Status
Last data maintenance date 20.03.2025

service life, electrical See Graph
rated conditions 0.43W
test voltage (coil/contact) 4 kVrms(50Hz,1 min, coil/contact)
test voltage (changeover contact/changeover contact) 2.5 kVrms(50Hz,1 minute, changeover contact/changeover contact)
Rated overvoltage 6 kV (input/output)
4 kV (between changeover contacts)

coil side
Rated input voltage UN 24V DC
Input Voltage Range 19.2V DC ... 33.6V DC (20 °C)
to UNas reference See Graph
drives and functions monostable
drive (polarity) polarization
UN 18 mA
Typical Response Time 8 ms
Typical release time 10 ms
coil voltage 24V DC
protection circuit freewheeling diode
Operating voltage display yellow LED

switching
Contact Type 2 changeover contacts
Switch Contact Type single contact
Contact Material AgNi, hard gold plating
maximum switching voltage 30V AC
36V DC
Minimum Switching Voltage 100 mV (10 mA)
limit continuous current 50 mA
Maximum impact current 50 mA
minimum switching current 1 mA (24 V)
Maximum power rating (resistive load) 1.2W (24V DC)
Use Class CB Scheme (IEC 60947-5-1) AC15, 1.5 A/240V (N/O contact)
AC15, 2 A/250V (normally closed contact)
DC13, 2 A/24V (normally closed contact)
DC13, 0.2 A/250V (N/O contact)
switching: when the gold plating layer is destroyed
Considerations If the gold plating is damaged, the following values are applicable.
Contact Material AgNi
maximum switching voltage 250V AC/DC
Minimum Switching Voltage 5V (10 mA)
Maximum impact current 25 A (20 ms, normally open contact)
minimum switching current 10 mA (5 V)
Maximum power rating (resistive load) 192W (24V DC)
96W (available for 48V DC)
60W (available for 60V DC)
44W (available for 110V DC)
57W (available for 220V DC)
2000 VA (available for 250V AC)
switch capacity 2 A (24V, DC13)
0.2 A (at 110V, DC13)
0.2 A (250V, DC13)
2 A (24V, AC15)
2 A (120V, AC15)
2 A (250V, AC15)

Phoenix RIF-1-RPT-LDP-24DC/2X21AU-Relay Module 2903330