| movement direction |
Line-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground |
| Maximum continuous voltage Uc |
15V DC |
| 10V AC |
| Rated current |
≤ 1 A (25 °C) |
| UC, the effective working current IC |
≤ 5 & micro;A (per line) |
| Residual Flow IPE |
≤ 1 µA |
| Nominal discharge current In(8/20) & micro;s (core-core) |
≤ 250 A |
| Rated discharge current In(8/20)& micro;s (core-ground) |
≤ 250 A |
| Nominal discharge current In(8/20) & micro;s (core-signal ground) |
≤ 250 A |
| Nominal discharge current In(8/20)& micro;s (signal ground-ground) |
≤ 5 kA |
| Total discharge current ITotal(8/20) µs |
5 kA |
| rated power pulse current lan (1000)& micro;s (core-core) |
50 A |
| rated power pulse current lan (1000)& micro;s (core-ground) |
50 A |
| Nominal pulse current Ian (10/1000) & micro;s (line-signal ground) |
50 A |
| rated power pulse current lan (700)& micro;s (core-core) |
50 A |
| rated power pulse current lan (700)& micro;s (core-ground) |
50 A |
| Nominal pulse current Ian (10/700) & micro;s (line-signal ground) |
50 A |
| Output voltage limit 1 kV/& micro;s (core-core) static |
≤ 50V |
| output voltage limited to 1 kV/& micro;s (line-signal ground) static |
≤ 30V |
| Residual voltage ln,(wire-wire) |
≤ 55V |
| In(line-signal ground) |
≤ 30V |
| voltage protection level Up(core-core) |
≤ 55V (C1 - 250 A) |
| ≤ 55V (B2 - 25 A) |
| voltage protection level Up(line-ground) |
≤ 450V (C1 - 250 A) |
| ≤ 400V (B2 - 25 A) |
| voltage protection level Up(line-signal ground) |
≤ 30V (C1 - 250 A) |
| ≤ 30V (B2 - 25 A) |
| response time tA(core-core) |
≤ 1 ns |
| response time tA (core-ground) |
≤ 100 ns |
| response time tA (line-signal ground) |
≤ 1 ns |
| response time tA (shield-ground) |
≤ 100 ns |
| input attenuation AE, symmetric. |
Typical 0.3 dB (≤ 700 kHz / 100 Ω) |
| Typical 0.3 dB (≤ 700 kHz/150 Ω) |
| input attenuation AE, asymmetric. |
Typical 0.3 dB (≤ 400 kHz / 100 Ω) |
| Typical 0.3 dB (≤ 400 kHz / 150 Ω) |
| cut-off frequency fg(3 dB),100 Ω symmetric system |
Typical 2.5 MHz |
| cut-off frequency fg(3 dB),150 Ω symmetric system |
Typical 2.5 MHz |
| cutoff frequency fg (3 dB), asymmetric. 100 Ω in the system (signal ground) |
Typical 1.3 MHz |
| cutoff frequency fg(3 dB), asymmetric. 150 Ω in the system (signal ground) |
Typical 1.3 MHz |
| capacitance (core-core) |
Typical 1 nF (f = 1 MHz/VR= 0 V) |
| capacity (line-signal ground) |
Typical 2 nF (f = 1 MHz/VR= 0 V) |
| Surge protection fault alarm |
None |
| Impact tolerance (line-line) |
B2 - 1 kV / 25 A |
| C1 - 500V / 250 A |
| Surge current carrying capacity (line-signal ground) |
B2 - 1 kV/25 A |
| C1 - 500 V/250 A |
| Impact resistance (signal ground-ground) |
B2 - 4 kV / 100 A |
| C1 - 100V / 500 A |
| C2 - 10 kV/5 kA |
| alternating current carrying capacity (signal ground-ground) |
5 A - 1 s |