Phoenix PSR-SPP- 24DC/ESD/5X1/1X2/T10S-safety relay 2981509, safety relay, used for emergency stop and safety door monitoring, safety level up to SIL 3 or EN ISO 13849 standard Cat. 4, PL e, automatic or manual activation, 3 normally open contacts, 1 normally closed contact, 2 normally open contacts with 10 s fixed shutdown delay, pluggable direct plug-in terminal

Product Type safety relay
Product Series PSRclassic
Application Emergency stop button
safety door
grating
control Single and Dual Channel
mechanical life 10x 106Switch Times
Relay Model Electromechanical relay with mechanical interlocking contacts according to IEC/EN 61810-3
insulation characteristics
Overvoltage Level III
pollution level 2

rated conditions 3.6W
Rated operating mode 100% Eligible
Rated insulation voltage 250V AC
rated overvoltage/insulation 4 kV foundation safety isolation:
Between all current paths and housing
6 kV reinforced isolation withstand voltage:
Between 13/14, 23/24, 33/34 and the retention current path
Between 13/14, 23/24, 33/34
power supply
Rated control circuit supply voltage US 20.4V DC ... 26.4V DC
Rated control circuit supply voltage US 24V DC -15 % / +10%

Overview
US Typical 3.6W
Rated control supply current IS Typical 150 mA
Impulse current 200 mA (US)
< 40 mA (Us/Ixto S10)
< 150 mA (Us/Ixto S12)
> -60 mA (Us/Ixto S22)
< 40 mA (Us/Ixto S34)
< 40 mA (Us/Ixto S35)
power consumption < 40 mA (Us/Ixto S10)
< 40 mA (Us/Ixto S12)
> -40 mA (Us/Ixto S22)
0 mA (Us/Ixto S34)
< 5 mA (Us/Ixto S35)
input/start and feedback circuit voltage 24V DC -15 % / +10%
filter time 1 ms (at A1, at the voltage dip Us)
max. 1.5 ms (at S10, S12; test pulse width)
7.5 ms (at S10, S12; test pulse rate)
test pulse rate = 5 x test pulse width
Typical Response Time < 600 ms (auto start)
< 70 ms (manual reset)
Typical startup time (Us) < 600 ms (when controlled via A1)
Typical release time < 20 ms (when controlled by s11/S12 and S21/S22)
< 20 ms (when controlled via A1)
parallel
Recovery Time < 1 s
delay time K3(t), K4(t) fixed by mode
Maximum switching frequency 0.5Hz
protection circuit Surge protection; Suppressor diode
Allowable total conductor resistance about 11 Ω (US)
Operating voltage display 1 x LED (green)
Status Display 4 x LED (green)

Contact Type 5 normally open safety contact outputs
1 signal transmission current path
Contact Material AgSnO2
maximum switching voltage 250V AC/DC (note load curve)
Minimum Switching Voltage 5V AC/DC
limit continuous current 6 A (N/O contact, note attenuation)
6 A (normally closed contact)
Maximum impact current 20 A (& Delta;t -100 ms, no delay contact)
8 A (time delay contact)
Minimum impulse current 10 mA
the square of the total current value 55 A2(pay attention to capacity reduction)
Maximum power rating (resistive load) 144W (24VDC,t=0ms)
288W (48VDC,t=0ms)
110W (110V DC, & tau; = 0 ms, delay contact: 77W)
88W (220VDC,t=0ms)
1500 VA (250V AC, & tau; = 0 ms, delay contact: 2000 VA)
Maximum power rating (inductive load) 42W (24V DC, & tau; = 40 ms, delay contact: 48W)
42W (48V DC, & tau; = 40 ms, delay contact: 40W)
42W (110V DC, & tau; = 40 ms, delay contact: 35W)
42W (220V DC, & tau; = 40 ms, delay contact: 33W)
Minimum on-off capacity 50 mW
On-off capacity (360/h cycle) 4 A (24V DC)
4 A (230V AC)
on-off capacity (3600/h cycle) 2.5 A (24V (DC13))
3 A (230V (AC15))
output fuse 10 A gL/gG (N/O contact)
6 A gL/gG (normally closed contact)

Phoenix PSR-SPP- 24DC/ESD/5X1/1X2/T10S-Safety Relay 2981509