Phoenix PSR-SPP- 24DC/FSP2/2X1/1X2-coupling relay 2986588, safety coupling relay, can meet various SIL 2 application requirements, can connect digital output signal to I/O,2 normally open safety contact outputs, 1 signal contact, suitable for safe state closed applications, integrated test pulse filter, pluggable in-line connection terminal, width: 17.5mm
Product Type
coupling relay
product series
PSRclassic
Application
Safety Shutdown
high requirements
low requirements
control
single channel
mechanical life
10x 106Switch Times
Relay Model
Electromechanical relay with mechanical interlocking contacts according to IEC/EN 61810-3
insulation characteristics
Overvoltage Level
III
pollution level
2
Typical startup time (Us)
50 ms (when controlled by A1, with Us)
Typical release time
50 ms (when controlled by A1, with Us)
Recovery Time
1 s
rated conditions
2.4W
Rated operating mode
100% Eligible
Rated insulation voltage
250V AC
rated overvoltage/insulation
control circuits A1/A2), (31/32), (13/14), 23/24 6 kV
Power
Name
A1/A2
Rated control circuit supply voltage US
24V DC -15 % / +10%
Rated control supply current IS
typical value 55 mA (in UStypical)
US
Typical 1.32W
Impulse current
maximum 100 mA (in UStypical)
filter time
max. 5 ms (Usvoltage dips)
max. 2 ms (test pulse width; high test pulse at A1/A2)
≥ 100 ms (test pulse width; high test pulse at A1/A2)
test pulse rate = 80 x test pulse width
max. 5 ms (test pulse width; low test pulse at A1/A2)
≥ 50 ms (test pulse rate; low test pulse at A1/A2)
test pulse rate = 15 x test pulse width
protection circuit
Surge protection; Suppressor diode, 33V (A1-A2)
relay: enable current path (13/14, 23/24)
Output Description
2 x normally closed contacts, not delayed
outputs
2
Contact Type
2 normally open safety contact outputs
Contact Material
AgCuNi,+ 0.2 µm Au
on-off capacity
75 mW minimum
Impulse current
max. 5 A
limit continuous current
5 A
the square of the total current value
50 A2(pay attention to capacity reduction)
Switching frequency
max. 0.5Hz
mechanical life
107Switch Times
output fuse
10 A gL/gG
relay: 31/32
Output Description
1 normally closed signal contact
outputs
1
Contact Type
1 feedback loop
Contact Material
AgCuNi,+ 0.2 µm Au
on-off capacity
75 mW minimum
Impulse current
Max. 100 mA
limit continuous current
100 mA
mechanical life
107Switch Times
output fuse
4 A gL/gG
connection technology
pluggable
is
Wire Connection
Connection Mode
in-line connection
Rigid conductor cross section
0.2 mm² ... 1.5 mm²
Flexible Wire Cross Section
0.2 mm² ... 1.5 mm²
Flexible conductor cross-section, with sleeve, with plastic insulation sleeve