Phoenix PSR-SPP- 24UC/ESA2/4X1/1X2/B-safety relay 2963954, safety relay, used for emergency stop and safety door, safety level can reach SIL 1, Cat. 1, PL c, according to specific application, can meet SIL 3, Cat. 4, PL e safety level requirements, single channel operation, automatic/manual start, 4 enable current paths, US = 24V DC, pluggable in-line terminal

Product Type safety relay
Product Series PSRclassic
Application Emergency stop button
safety door
control single channel
mechanical life 10x 106Switch Times
Relay Model Electromechanical relay with mechanical interlocking contacts according to IEC/EN 61810-3
insulation characteristics
Overvoltage Level III
pollution level 2
Typical Response Time < 100 ms (for Usauto start)
< 100 ms (with Usmanual start)
Typical startup time (Us) < 100 ms (with Us/via A1 control)
Typical release time < 10 ms (at Us, as required, via sensor loop)
< 100 ms (in Us/as needed, via A1)
restart time < 1 s (start-up time)
Recovery Time < 1 s (meet the requirements of safety function)
Start Pulse Length ≥ 500 ms (manual reset)

rated conditions 16W (US= 26.4 V, IL² = 72 A²,PTotal Maximum= 1.6W +14.4 W)
Rated operating mode 100% Eligible
Rated insulation voltage 250V AC
rated overvoltage/insulation 4 kV foundation safety isolation:
Between all current paths and housing
6 kV reinforced isolation withstand voltage:
Between A1/A2 and 13/14, 23/24, 33/34, 43/44
Between S11/S12/S33/S34 and 13/14, 23/24, 33/34, 43/44
Between 51/52 and 13/14, 23/24, 33/34, 43/44
power supply
Rated control circuit supply voltage US 24V DC -15 % / +10%
Rated control supply current IS typical value 55 mA (US)
US Typical 1.32W
Impulse current < 3.5 A (by US,&Delta;t = 2 ms)
filter time 2 ms (Usvoltage dips)
protection circuit series protection to prevent polarity reversal; suppression diode

Digital Quantity: Logic (S12)
Input Description safety related
Input Quantity 1
input voltage range, "0" signal 0V DC ... 5V DC
input voltage range, "1" signal 20.4V ... 26.4V
Input current range "0" signal 0 mA ... 2 mA
Impulse current 80 mA (voltage is usually US,&Delta;t = 150 ms)
filter time does not allow brightness test pulse/high test pulse.
1 ms (test pulse width of low test pulse)
1 s (test pulse rate for low test pulses)
Allowable Total Conductor Resistance 50 Ω
protection circuit Suppressor Diode
power consumption typical value 50 mA (U at S11S)
typical 52 mA (supplied by external US)
digital quantity: starting circuit (S34)
Input Description non-safety related
Input Quantity 1
input voltage range, "1" signal 20.4V ... 26.4V
Impulse current < 6 mA (the voltage is usually US,&Delta;t = 65 ms)
filter time Test pulse not allowed
Allowable Total Conductor Resistance 50 Ω
protection circuit Suppressor Diode
power consumption 0 mA (in UStypical)

relay: enable current path
Output Description 2 normally open contacts in series, safety-related, floating
outputs 4
Contact Type 4 normally open safety contact outputs
Contact Material AgSnO2
Switching voltage 10V minimum
Max. 250V AC/DC
on-off capacity 100 mW minimum
Impulse current 10 mA minimum
Max (& Delta;t = 100 ms)
limit continuous current 6 A
the square of the total current value 72 A2(pay attention to capacity reduction)

Phoenix PSR-SPP- 24UC/ESA2/4X1/1X2/B-Safety relay 2963954