Phoenix Class BLT-T2-1S-320-UT-2 surge protector 2906101, Class 2 surge protector, used to install in lighting equipment, distribution box, trunking, underground installation or direct installation of terminal equipment. Dedicated for insulation class I with optional fault indication. Can be branched or routed through. Model: 230V AC

Product Type surge protector
IEC Category II / III
T2 / T3
EN Type T2 / T3
IEC power supply system TN-S
TT
type Installation Module
Surge protection fault alarm with visual status indication window
insulation characteristics
protection level I
Overvoltage Category III
pollution level 2

Rated frequency fN 50Hz (60 Hz)
Rated voltage UN 100V AC ... 277V AC (TN-S)
100V AC ... 277V AC (TT)
dielectric strength < 6 kV

Connection Mode screw connection terminal
thread M3
Tightening torque 0.6 Nm
Flexible Wire Cross Section 0.2 mm² ... 2.5 mm²
Rigid conductor cross section 0.2 mm² ... 4 mm²

Dimensional drawing
width 36.5mm
height 56mm
depth 34mm

color light gray (RAL 7035)
flame retardant rating, according to UL 94 V-0
material 600
insulation material PA 6.6
Material Group I
Shell Material PA 6.6

protection channel L-N
L-PE
N-PE
Direction of action 1L-N & N-PE
Rated voltage UN 100V AC ... 277V AC (TN-S)
100V AC ... 277V AC (TT)
Rated frequency fN 50Hz (60 Hz)
Maximum continuous operating voltage UC(L-N) 320V AC
Maximum continuous operating voltage UC(L-PE) 305V AC
Maximum continuous operating voltage UC(N-PE) 305V AC
Rated load current IL 16 A
Residual Flow IPE ≤ 5 &micro;A
Nominal discharge current In(8/20) &micro;s (L-N) 5 kA
Nominal discharge current In(8/20) &micro;s (L-PE) 5 kA
Nominal discharge current In(8/20) &micro;s (N-PE) 10 kA
Maximum discharge current Imax(8/20) &micro;s (L-N) 10 kA
Maximum discharge current Imax(8/20) &micro;s (L-PE) 10 kA
Maximum discharge current Imax(8/20) &micro;s (N-PE) 20 kA
Combined surge UOC 10 kV
Total discharge current ITotal(8/20) &micro;s 20 kA
Rated open freewheeling value Ifi(N-PE) 100 A (305V AC)
Rated short-circuit current ISCCR 3 kA
voltage protection level Up(L-N) ≤ 1.3 kV
voltage protection level Up(L-PE) ≤ 1.5 kV
voltage protection level Up(N-PE) ≤ 1.4 kV
Residual pressure Ures(L-N) ≤ 1.3 kV (In)
≤ 1.3 kV (UOC)
UT(L-N) 400V AC (5 seconds/withstand mode)
528V AC (120 min/safe failure mode)
UT(L-PE) 528V AC (5 seconds/withstand mode)
528V AC (120 min/safe failure mode)
1505V AC (200 ms/withstand mode)
UT(N-PE) 1200V AC
response time tA(L-N) ≤ 25 ns
response time tA(N-PE) ≤ 100 ns
Maximum spare fuse with V-connection wire 16 A (MCB B /C)
maximum spare fuse with branch wiring 16 A (MCB B /C)