Phoenix FLT-SEC-P-T1-1C-264/50-FM-1 Class 2 combined surge protector 2907387, plug-in lightning protection surge protector without leakage current, meet the requirements of Class 1/Class I, used in single-phase power supply network, protection Grounding and neutral wires are integrated (L1, PEN).

Product Type combination type
product series SEC Family
IEC Category I / II
T1 / T2
EN Type T1 / T2
IEC power supply system TN-C
TT
type DIN rail module, split, detachable
Bits 1
Surge protection fault alarm visual status indication window and remote alarm contact
insulation characteristics
Overvoltage Category III
pollution level 2

Rated frequency fN 50Hz (60 Hz)
indicator/remote signaling
Connection Name Remote alarm contact
switching function changeover contact
Nominal operating voltage 12V AC ... 250V AC
125V DC (200 mA DC)
Operating current 10 mA AC ... 1 A AC
1 A DC (30V DC)

Connection Mode screw connection
thread M5
Tightening torque 4.5 Nm
stripping length 18mm
Flexible Wire Cross Section 2.5 mm² ... 35 mm²
Rigid conductor cross section 2.5 mm² ... 35 mm²
Attachable Guide Cross Section AWG 13 ... 2
Connection Mode fork cable end
Flexible Wire Cross Section 1.5 mm² ... 16 mm²
Remote alarm contact
Connection Mode COMBICON in-line/screw connection
thread M2
Tightening torque 0.25 Nm
stripping length 7mm
Flexible Wire Cross Section 0.14 mm² ... 1.5 mm²
Rigid conductor cross section 0.14 mm² ... 1.5 mm²
Attachable Guide Cross Section AWG 28 ... 16

Dimensional drawing
width 35.6mm
height 95.2mm
depth 74.5mm (7.5mm with DIN rail)
Horizontal stitch pitch Division 2

color (pin connector) light gray (RAL 7035)
color (basic element) gray (RAL 7042)
flame retardant rating, according to UL 94 V-0
material 600
insulation material PA6.6-FR 20% GF
PBT-FR
Material Group I
Shell Material PA 6.6-FR 20 % GF
PBT-FR

Mechanical parameters
Open Side Panel No

protection channel L-PEN
movement direction 1L-N/PE
Rated voltage UN 240V AC (TN-C)
240V AC (TT)
Rated frequency fN 50Hz (60 Hz)
Maximum continuous operating voltage UC 264V AC
Rated load current IL 125 A (< 55 °C)
Nominal discharge current In(8/20)&micro;s 50 kA
Maximum discharge current Imax(8/20) &micro;s 100 kA
impulse discharge current (10/350)& micro;s, charging 25
impulse discharge current (10/350)& micro;s, specific energy 625 kJ/Ω
impulse discharge current (10/350)& micro;s, peak limp 50 kA
Disconnect freewheeling capacity Ifi 50 kA
Rated short-circuit current ISCCR 50 kA