Phoenix SFP 1-20/230AC-EMC filter surge protection equipment 2859987, equipment protection, in line with Class 3/Class III, with network interference suppression filter to prevent high-frequency interference voltage, used for single-phase power supply network, zero Ground separation (3-wire system: L1, N, PE), with remote signaling contacts.

Product Type interference suppression filter
Product Series SFP
type rail mounting module, monolithic
Bits 2
D, A, I, NL, S, E, FIN, P
Surge protection fault alarm visual status indication window and remote alarm contact
insulation characteristics
Overvoltage Category III
pollution level 2
IEC Category III
T3
EN Type T3
Ports Two

indicator/remote signaling
Connection Name Remote alarm contact
switching function changeover contact
Nominal operating voltage 12V AC ... 250V AC
250V DC (250 mA DC)
working current 100 mA AC ... 1 A AC
1 A DC (48V DC)

Connection Mode screw connection terminal
thread M3
Tightening torque 0.5 Nm ... 0.6 Nm
4.5 lbf-in. ... 5.5 lbf-in.
Flexible Wire Cross Section 2.5 mm² ... 4 mm²
Rigid conductor cross section 2.5 mm² ... 6 mm²
Attachable Guide Cross Section AWG 14 ... 10

Dimensional drawing
width 112mm
height 86.6mm
depth 79mm

color black (RAL 9005)
silver
flame retardant rating, according to UL 94 V-0
insulation material ABS
Shell Material Aluminum

Mechanical parameters
Open Side Panel No

protection channel L-N
L-PE
N-PE
movement direction L-N & L(N)-PE
Rated voltage UN 240V AC (TN)
240V AC (TT-only with RCD)
240V AC (IT-only with RCD)
Rated frequency fN 50Hz (60 Hz)
Maximum continuous operating voltage UC 264V AC
Rated load current IL 20 A (40 °C)
Residual Flow IPE ≤ 0.6 mA
Standby power consumption PC ≤ 25 VA (UREF)
≤ 27.5 VA (UC)
Reference test voltage UREF 264V AC
Nominal discharge current In(8/20)µs 5 kA
Combined surge UOC 10 kV (5 kA)
voltage protection level Up ≤ 1 kV
UT(L-N) 350V AC (5 seconds/withstand mode)
457V AC (120 min/safe failure mode)
UT(L-PE) 457V AC (5 seconds/withstand mode)
350V AC (120 min/tolerance mode)
1464V AC (200 ms/safety failure mode)
UT(N-PE) 1200V AC (200 ms/SAFE mode)
response time tA ≤ 25 ns
capacity (L-N) 1 µF ±10%
10 nF ±10 % (X2-275 V)
capacity (L-PE) 2.2 nF ±20 % (Y2-250 V)
capacity (N-PE) 2.2 nF ±20 % (Y2-250 V)
20 A (MCB B/Universal)
16 A (IT-MCB B/General)
input attenuation AE, symmetric. 20 dB (≥ 100 kHz / 50 Ω)
input attenuation AE, asymmetric. 30 dB (≥ 1 MHz / 50 Ω)