Phoenix EC-E4 3A-electronic equipment circuit breaker 0903034, electronic circuit breaker, signal contact: 1 normally closed contact, rated current: 3 A

Product Type Equipment circuit breaker
Product Series EC-E
type rail mounting module, monolithic
Bits 1
Channels 1
insulation characteristics
pollution level 2

Fuse Type automatic equipment
Switch capacity ICN Active Current Limit
Fuse electronic
Overview
Nominal operating voltage 24V DC
18V DC ... 32V DC
Rated current IN 3 A
Rated overvoltage 0.5 kV
Breaking method E (Electronic)
not required, built-in intrinsic safety components
dielectric strength 32V DC max (load circuit)
Close Model. 1.8 x IN
Active Current Limit active
Fuse electronic
Closed Circuit Current Range I0 Typical 25 mA ± 5 mA (when switched on)
MTBF (IEC 61709, SN 29500) 7430000 h (at 80% load at 25°C)
6590000 h (at 40°C, 80% load)
voltage drop 80 mV (IN)
Contact Type without electrical isolation
Load Circuit
Maximum capacitive load 20000 µF
impact suppression Typical 0.5 s
auxiliary contact
Contact Type remote signaling alarm contact
Minimum operating voltage UminDC 10V DC
Maximum operating voltage UmaxDC 30V DC
Minimum operating current Imin 10 mA
Maximum operating current Imax 0.5 A
indicator/remote signaling
Connection Name auxiliary contact
switching function normally closed contact

Rated cross section 16.00 mm²
Line+ / LOAD+ /0V
Connection Mode screw connection
thread M4
Tightening torque ... 1.2 Nm
stripping length 10mm
Rigid conductor cross section 0.5 mm² ... 16 mm²
cross-section AWG 20 ... 6 (as amended by IEC standards)
Flexible Wire Cross Section 0.5 mm² ... 16 mm²
WIRE CROSS SECTION, FLEXIBLE [AWG] 20 ... 6 (as amended by IEC standards)
Flexible conductor cross-section (sleeve without plastic insulation) 0.5 mm² ... 10 mm²
flexible conductor cross-section (sleeve with plastic insulating tube) 0.5 mm² ... 10 mm²
2 wires of the same cross section, rigid wire 0.5 mm² ... 4 mm²
2 wires of the same cross section, AWG rigid 20 ... 12 (as amended by IEC standards)
2 wires with the same cross section, flexible wire 0.5 mm² ... 4 mm²
2 wires of the same cross section, AWG flexible 20 ... 12 (as amended by IEC standards)
2 wires with the same cross section, flexible, with sleeve but not plastic sleeve 0.5 mm² ... 2.5 mm²
2 wires with the same cross section, flexible, with TWIN sleeve and plastic sleeve 0.5 mm² ... 6 mm²
Rated cross section 16 mm²
auxiliary contact
Connection Mode screw connection
thread M3
Tightening torque ... 0.5 Nm
stripping length 8mm
Flexible conductor cross-section (sleeve without plastic insulation) 0.25 mm² ... 2.5 mm²
flexible conductor cross-section (sleeve with plastic insulating tube) 0.25 mm² ... 2.5 mm²

Phoenix EC-E4 3A-Electronic Equipment Circuit Breaker 0903034

Created on:2025-09-19 09:10