Phoenix CABLE-D- 9SUB/F/OE/0,25/S/3,0M-cable 2926056, prefabricated round shielded cable; connection 1: single wire (9-position) (the cable is marked and equipped with a sleeve. The braided shield is connected to both ends of the cable.); Connection 2: D-SUB-hole socket board (1x 9-position); Cable length: 3 m

Product Type System Cable

environmental conditions
protection level IP20
protection level (installation position) ≥ IP54 (installation position)
Ambient temperature (operating) (fixed installation) -40°C ... 70°C (fixed installation)
ambient temperature (operating) (movable installation) -10°C ... 70°C (movable installation)
ambient temperature (storage/transport) -40°C ... 80°C
elevation ≤ 2000 m

Nominal operating voltage (AC) ≤ 30V AC
Nominal operating voltage (DC) ≤ 60V DC
Rated operating mode 100% Eligible
current (per path) ≤ 2 A (expanded, see attenuation)

Cable Length 3 m
9X0.25 [PVC]
UL AWM 2464/1061
Bits 9
Shielding have
Cable Type 9X0.25 [PVC]
Wire Model prefabricated circular shielded cable
wire structure signal line 14x 0.15mm
AWG, signal wire 24
Wire Cross Section 9x 0.25 mm²
wire diameter, including insulation 1.2mm ± 0.05mm
Cable outer diameter 6.70mm ± 0.5mm
outer sheath, material semi-rigid PVC
outer sheath, color Grey
Wire Material copper stranded wire
Cable resistance ≤ 80 Ω/km (20 °C)
insulation resistance ≥ 20 MΩ*km (20 °C)
Rated voltage, cable 300V AC/DC
minimum bending radius, fixed mounting 58mm
minimum bending radius, mobile installation 108mm
Dynamic Load Capacity (Bending) : 5000 (radius ≥ 15x outer diameter)
Halogen-free No
flame retardant IEC 60332-1-2 (bare cable)
VDE 0842, Part 332-1-2 (Bare cables)
IEC 60332-3-22 (bare cable)
UL VW-1
CSA FT-1
oil resistance Resistance to occasional welding chip spatter (bare cable)
color coding: single line
White D-SUB9 (1) = ()
Brown D-SUB9 (2) = ()
Green D-SUB9 (3) = ()
yellow D-SUB9 (4) = ()
Grey D-SUB9 (5) = ()
pink D-SUB9 (6) = ()
Blue D-SUB9 (7) = ()
Red D-SUB9 (8) = ()
Black D-SUB9 (9) = ()

connection 1
Connection Mode single line
stripping length (sheath) 150mm
Bits 9
Considerations cables are marked and fitted with sleeves. The braided shields are attached to both ends of the cable respectively.
Connection 2
connection meets standards IEC 60807-2
DIN 41652
Connection Mode D-SUB hole socket plate
thread UNC 4-40
connection quantity 1
Bits 9
Tightening torque 0.2 Nm
Insertion/unplugging cycle > 200
needle pitch 2.74mm