Phoenix PSR-M Series: Industrial Safety Relays - Selection Guide

Overview

Phoenix PSR-M Series are high-reliability industrial safety relays designed for safeguarding personnel and equipment in automation systems. They monitor safety-related circuits (e.g., emergency stops, safety doors, light curtains) and trigger controlled shutdowns when hazards occur. With flexible contact configurations, wide voltage compatibility, and compliance with global safety standards (SIL, EN), they’re ideal for machine tools, conveyors, and industrial production lines requiring fail-safe protection.

Model & Core Parameter Table

Model No. Product Name Input Voltage Contact Configuration Special Features Application Scenario
1301404 PSR-ME20-3NO-1NC-24DC-SC-SET35 24V DC 3 Normally Open (NO) + 1 Normally Closed (NC) SC (Selective Coordination) + SET35 mounting kit Small-scale safety circuits (24V DC)
1301402 PSR-ME20-3NO-1NC-24DC-SC 24V DC 3NO + 1NC SC function Compact 24V safety loops
2702383 PSR-MC82-5NO-1NC-1DO-24DC-SP 24V DC 5NO + 1NC + 1 Digital Output (DO) SP (Standard Protection) Complex safety systems (multi-channel monitoring)
2702382 PSR-MC82-5NO-1NC-1DO-24DC-SC 24V DC 5NO + 1NC + 1DO SC function Complex 24V safety loops with selective coordination
2700525 PSR-MC32-3NO-1NC-24-230UC-SP 24-230V AC/DC (UC) 3NO + 1NC SP + Wide voltage Universal voltage safety circuits
2700524 PSR-MC32-3NO-1NC-24-230UC-SC 24-230V AC/DC (UC) 3NO + 1NC SC + Wide voltage Universal voltage loops with SC
1015503 PSR-MC31-2SDO-1DO-24DC-SP 24V DC 2 Safe Digital Outputs (SDO) + 1DO SP + Safe outputs Safety-related output control
1015520 PSR-MC31-2SDO-1DO-24DC-SC 24V DC 2SDO + 1DO SC + Safe outputs Safe output control with SC
2700499 PSR-MC30-2NO-1DO-24DC-SP 24V DC 2NO + 1DO SP function Basic 24V safety-output integration
2700498 PSR-MC30-2NO-1DO-24DC-SC 24V DC 2NO + 1DO SC function Basic 24V loops with SC
2700467 PSR-MC20-3NO-1DO-24DC-SP 24V DC 3NO + 1DO SP function Medium-scale 24V safety circuits
2700466 PSR-MC20-3NO-1DO-24DC-SC 24V DC 3NO + 1DO SC function Medium-scale 24V loops with SC

Simplified Model Code Interpretation

  • PSR-ME/MC: Product sub-series (ME=entry-level; MC=mid-range with extended functions)
  • Numbers (20/30/31/32/82): Model specification (indicates contact quantity/function complexity)
  • Contact Marks:
    • NO = Normally Open (closes when activated)
    • NC = Normally Closed (opens when activated)
    • DO = Digital Output (standard control output)
    • SDO = Safe Digital Output (safety-rated output for critical control)
  • Voltage: 24DC (24V DC); 24-230UC (universal 24-230V AC/DC)
  • SP/SC: Protection function (SP=Standard Protection; SC=Selective Coordination, avoids cascading tripping)
  • SET35: Includes 35mm DIN rail mounting kit

Core Specifications (Unified for Series)

Spec Item Details
Safety Certifications SIL 3, EN 60947-5-1, EN ISO 13849-1 (PLe)
Operating Temperature -25°C~70°C (continuous industrial use)
Contact Capacity Up to 10A/250V AC, 6A/24V DC (switching load)
Response Time ≤10ms (fast hazard response)
Installation 35mm DIN rail (SET35 models include mounting kit)
Housing Protection IP20 (control cabinet installation)
Fault Indication LED indicators for power, status, and faults

Intuitive Selection Table (At-a-Glance)

Application Scenario Key Requirements Recommended Models Core Reason
Small-scale 24V safety circuits (e.g., single emergency stop) 3NO+1NC, compact size 1301402 (SC), 1301404 (SC+SET35) Entry-level, fits basic safety loops
Complex multi-channel safety (e.g., multiple safety doors) 5NO+1NC+1DO, high contact count 2702382 (SC), 2702383 (SP) 5 NO contacts for multi-device monitoring
Universal voltage (24-230V AC/DC) systems Wide voltage compatibility 2700524 (SC), 2700525 (SP) UC design fits global power standards
Safe output control (critical shutdowns) SDO for safety-related outputs 1015503 (SP), 1015520 (SC) SDO ensures fail-safe output behavior
Basic safety + standard output integration 2NO/3NO + 1DO 2700498 (SC), 2700466 (SC) Combines safety monitoring with control outputs
Complex control cabinets (avoid cascading tripping) Selective Coordination (SC) All SC-marked models Prevents entire system shutdown from single-loop faults

Key Advantages

  • Global Safety Compliance: Certifications (SIL 3, PLe) meet international safety standards, ensuring regulatory compliance.
  • Flexible Contact Configurations: From 2NO to 5NO + NC/DO/SDO options, matching simple to complex safety circuits.
  • Wide Voltage Adaptability: Universal (UC) models cover 24-230V AC/DC, reducing inventory for global deployments.
  • Selective Coordination (SC): SC models isolate faults to specific loops, minimizing production downtime.
  • Easy Troubleshooting: LED indicators quickly identify power, status, and fault conditions, simplifying maintenance.

Important Notes:

  1. Voltage Matching: Choose 24DC models for DC systems and UC models for mixed AC/DC or global applications.
  2. SC vs. SP: Use SC models in complex cabinets to avoid cascading tripping; SP models for basic, standalone safety loops.
  3. Contact Capacity: Ensure contact current rating exceeds the total load current (add 20% margin for reliability).
  4. Safety Outputs: For critical shutdowns, prioritize SDO-equipped models (1015503/1015520) for fail-safe behavior.
  5. Mounting: SET35 models include a DIN rail kit; standard models require separate mounting hardware.