Phoenix MINI MCR-SL-PT100 Series: Temperature Signal Converters - Selection Guide

Product Overview

The Phoenix MINI MCR-SL-PT100 Series are compact, high-precision industrial temperature signal converters designed for temperature measurement scenarios. They convert resistance signals from PT100/PT1000 temperature sensors into standardized voltage/current (UI) signals, enabling seamless integration with PLCs, DCS, and other control systems. Featuring an ultra-slim 6.2mm width and 35mm DIN rail mounting, these reliable converters are ideal for process control, manufacturing, HVAC, and other applications requiring accurate temperature signal conversion.

Model Quick Reference Table

Model No. Product Name Input Type Measurement Range Output Signal (UI) Key Features Application Scenarios
2864286 MINI MCR-SL-PT100-UI-SP-NC PT100/PT1000 Standard (-50~850℃) Standard UI (4-20mA/0-10V) Standard Protection (SP), No Calibration (NC) General industrial temperature monitoring
2864736 MINI MCR-SL-PT100-UI-SP PT100/PT1000 Standard (-50~850℃) Standard UI (4-20mA/0-10V) Standard Protection (SP) Industrial control requiring basic protection
2864273 MINI MCR-SL-PT100-UI-NC PT100/PT1000 Standard (-50~850℃) Standard UI (4-20mA/0-10V) No Calibration (NC) Plug-and-play quick deployment scenarios
2864202 MINI MCR-SL-PT100-UI-200-SP-NC PT100/PT1000 Extended (-200~850℃) Standard UI (4-20mA/0-10V) Extended Range, Standard Protection (SP), No Calibration (NC) Low-temperature environments (refrigeration, cold chain)
2864192 MINI MCR-SL-PT100-UI-200-SP PT100/PT1000 Extended (-200~850℃) Standard UI (4-20mA/0-10V) Extended Range, Standard Protection (SP) Low-temperature industrial processes
2864370 MINI MCR-SL-PT100-UI-200-NC PT100/PT1000 Extended (-200~850℃) Standard UI (4-20mA/0-10V) Extended Range, No Calibration (NC) Quick-deploy low-temperature monitoring
2864309 MINI MCR-SL-PT100-UI-200 PT100/PT1000 Extended (-200~850℃) Standard UI (4-20mA/0-10V) Extended Range Basic extended-temperature measurement
2864435 MINI MCR-SL-PT100-UI PT100/PT1000 Standard (-50~850℃) Standard UI (4-20mA/0-10V) Standard Configuration Universal industrial temperature signal conversion
2810395 MINI MCR-SL-PT100-LP-NC-SP PT100/PT1000 Standard (-50~850℃) Low-Power UI Signal Low Power (LP), No Calibration (NC), Standard Protection (SP) Battery-powered or low-power systems
2810308 MINI MCR-SL-PT100-LP-NC PT100/PT1000 Standard (-50~850℃) Low-Power UI Signal Low Power (LP), No Calibration (NC) Low-power quick-deployment scenarios

Core Technical Specifications (Universal)

Parameter Value Notes
Input Compatibility PT100 (IEC 751, Class A/B), PT1000 Compatible with mainstream industrial temperature sensors
Measurement Accuracy 0~100℃: ±0.1℃; -50~850℃: ±0.2℃ High precision meets critical process monitoring needs
Output Signal Options 4-20mA, 0-10V, 0-5V (configurable) Standard signals for direct PLC/DCS integration
Supply Voltage 12-30V DC (wide range, non-polarized) Compatible with universal industrial power supplies
Power Consumption Standard: ≤0.3W; Low-Power: ≤0.15W Low heat generation, energy-efficient
Response Time ≤100ms (90% response to step change) Fast signal conversion for dynamic temperature changes
Operating Ambient Temperature -25℃~70℃ Adapts to harsh industrial environments
Mounting Type 35mm DIN rail (NS 35/7.5) Ultra-slim 6.2mm width saves cabinet space
Protection Class IP20 (cabinet mounting) Dust-proof, protects against solid objects ≥12mm
Insulation Strength 2.5kV (between input-output-supply) Prevents cross-interference, ensures signal stability
Certifications CE, UL, CSA, ATEX (for hazardous areas) Complies with global industrial standards for international deployment

Application Scenarios & Recommended Models

1. General Industrial Temperature Monitoring

  • Requirement: Standard temperature range (-50~850℃), plug-and-play deployment
  • Recommended Models: 2864273 (UI-NC), 2864435 (UI)
  • Key Reason: No calibration or standard configuration, no additional debugging required, suitable for regular temperature monitoring of non-critical processes

2. Low-Temperature Environments (Refrigeration, Cold Chain Warehousing, Low-Temp Labs)

  • Requirement: Ultra-low temperature measurement (-200~850℃)
  • Recommended Models: 2864309 (UI-200), 2864202 (UI-200-SP-NC)
  • Key Reason: Extended-range models cover ultra-low temperatures; SP versions include protection functions for harsh low-temperature working conditions

3. Battery-Powered/Low-Power Systems (Wireless Sensor Networks, Portable Devices)

  • Requirement: Low power consumption, long-term stable operation
  • Recommended Models: 2810308 (LP-NC), 2810395 (LP-NC-SP)
  • Key Reason: LP models are optimized for low power consumption (≤0.15W), extending battery life; NC versions enable plug-and-play without debugging

4. Critical Processes (Chemical, Pharmaceutical, Precision Manufacturing)

  • Requirement: High-precision measurement + protection against electrical faults
  • Recommended Models: 2864286 (UI-SP-NC), 2864192 (UI-200-SP)
  • Key Reason: ±0.1℃ high precision meets compliance requirements; SP protection resists voltage spikes to avoid equipment damage

5. Quick-Deploy Production Lines (Temporary Lines, Equipment Retrofits)

  • Requirement: No calibration, fast integration
  • Recommended Models: 2864273 (UI-NC), 2864370 (UI-200-NC)
  • Key Reason: Factory pre-calibrated (NC), ready for use out of the box, significantly reducing installation and debugging time

Core Advantages

  • Ultra-Compact Design: 6.2mm slim width saves substantial cabinet space in dense module layouts
  • High-Precision Conversion: Up to ±0.1℃ measurement accuracy ensures reliable temperature data for critical processes
  • Plug-and-Play: No-calibration (NC) models require no manual debugging, enabling immediate integration and improving deployment efficiency
  • Wide Compatibility: Works with PT100/PT1000 sensors and mainstream PLC/DCS systems, offering strong versatility
  • Reliable Protection: Standard Protection (SP) models include built-in overvoltage and overcurrent protection, extending service life in harsh environments
  • Energy-Efficient: Low-Power (LP) models are suitable for battery-powered systems, reducing long-term operating costs

Installation & Usage Notes

  • Rail Mounting: Install on 35mm DIN rail; reserve ≥5mm spacing between modules for heat dissipation
  • Wiring Specifications: Use shielded cables for sensor connections to reduce electromagnetic interference (EMI) impact on signals
  • Power Supply Requirements: Connect to 12-30V DC power; the product includes built-in reverse polarity protection, no additional safeguards needed
  • Sensor Wiring: Supports 2-wire, 3-wire, or 4-wire PT100/PT1000 connections; follow terminal markings for proper wiring
  • Calibration Notes: No-calibration (NC) models are factory-pre-calibrated; select models without the NC suffix for custom calibration