Phoenix MCR-S Series: Industrial Signal Converters - Selection Guide
Product Overview
The Phoenix MCR-S Series are high-precision industrial signal converters designed for on-site signal conditioning in industrial settings. They convert input signals of different ranges (e.g., millivolt, milliampere-level signals) into standardized voltage/current (UI) signals, compatible with PLCs, DCS, and other control systems to enable stable signal transmission and accurate data acquisition. Supporting 35mm DIN rail mounting, these compact and reliable converters are ideal for process control, manufacturing, automated production lines, and other scenarios requiring signal conversion and conditioning.
Model Quick Reference Table
| Model No. | Product Name | Input Range | Output Signal | Key Features | Application Scenarios |
|---|---|---|---|---|---|
| 2908798 | MCR-S-20-100-UI-DCI | 20-100 (corresponding to on-site signals) | Standardized UI signals (4-20mA/0-10V) | Fixed range, DC current compatible | Large-range on-site signal conversion |
| 2814731 | MCR-S-1-5-UI-SW-DCI-NC | 1-5 (corresponding to on-site signals) | Standardized UI signals (4-20mA/0-10V) | Small range, Signal Switching (SW), No Calibration (NC) | Small-range quick deployment scenarios |
| 2814650 | MCR-S-1-5-UI-SW-DCI | 1-5 (corresponding to on-site signals) | Standardized UI signals (4-20mA/0-10V) | Small range, Signal Switching (SW) | Small-range scenarios requiring signal switching |
| 2814715 | MCR-S-1-5-UI-DCI-NC | 1-5 (corresponding to on-site signals) | Standardized UI signals (4-20mA/0-10V) | Small range, No Calibration (NC) | Small-range plug-and-play scenarios |
| 2814744 | MCR-S10-50-UI-SW-DCI-NC | 10-50 (corresponding to on-site signals) | Standardized UI signals (4-20mA/0-10V) | Medium range, Signal Switching (SW), No Calibration (NC) | Medium-range quick deployment scenarios |
| 2814728 | MCR-S10-50-UI-DCI-NC | 10-50 (corresponding to on-site signals) | Standardized UI signals (4-20mA/0-10V) | Medium range, No Calibration (NC) | Medium-range plug-and-play scenarios |
| 2814647 | MCR-S-10/50-UI-DCI | 10-50 (corresponding to on-site signals) | Standardized UI signals (4-20mA/0-10V) | Medium range, fixed configuration | Routine medium-range signal conversion |
| 2814634 | MCR-S-1/5-UI-DCI | 1-5 (corresponding to on-site signals) | Standardized UI signals (4-20mA/0-10V) | Small range, fixed configuration | Routine small-range signal conversion |
Core Technical Specifications (Universal)
| Parameter | Value | Notes |
|---|---|---|
| Input Compatibility | Millivolt/milliampere-level on-site signals (matching model range) | Compatible with industrial sensor signals of different ranges |
| Measurement Accuracy | ±0.1% Full Scale (FS) | High-precision conversion ensures accurate signal acquisition |
| Output Signal Options | 4-20mA, 0-10V (configurable) | Standardized signals for direct PLC/DCS integration |
| Supply Voltage | 12-30V DC (wide voltage input) | Compatible with universal industrial power supplies |
| Power Consumption | ≤0.5W | Low heat generation, energy-efficient |
| Response Time | ≤200ms (90% response to step change) | Fast signal conversion for dynamic signal scenarios |
| Operating Ambient Temperature | -25℃~70℃ | Adapts to harsh industrial environments |
| Mounting Type | 35mm DIN rail (NS 35/7.5) | Compact design saves cabinet space |
| Protection Class | IP20 (cabinet mounting) | Dust-proof, protects against solid objects ≥12mm |
| Insulation Strength | 2.5kV (between input-output-supply) | Prevents cross-interference, ensures signal stability |
| Certifications | CE, UL, CSA | Complies with global industrial standards for international deployment |
Application Scenarios & Recommended Models
1. Small-Range On-Site Signal Conversion (e.g., 1-5mV/mA sensors)
- Requirement: Small-range signal conditioning, routine configuration
- Recommended Models: 2814634 (MCR-S-1/5-UI-DCI), 2814715 (MCR-S-1-5-UI-DCI-NC)
- Key Reason: Compatible with 1-5 range signals; NC models enable plug-and-play, while standard models meet customization needs
2. Small-Range Scenarios Requiring Signal Switching (e.g., alternate input from multiple sensors)
- Requirement: Small range, signal switching function, quick deployment
- Recommended Models: 2814650 (MCR-S-1-5-UI-SW-DCI), 2814731 (MCR-S-1-5-UI-SW-DCI-NC)
- Key Reason: SW function supports signal switching; NC versions eliminate debugging, suitable for multi-sensor alternating operation
3. Medium-Range On-Site Signal Conversion (e.g., 10-50mV/mA sensors)
- Requirement: Medium-range signal conditioning, plug-and-play
- Recommended Models: 2814728 (MCR-S10-50-UI-DCI-NC), 2814647 (MCR-S-10/50-UI-DCI)
- Key Reason: Compatible with 10-50 range signals; NC models shorten deployment time, while standard models ensure flexible configuration
4. Medium-Range Scenarios Requiring Signal Switching (e.g., multi-range sensor switching)
- Requirement: Medium range, signal switching, quick deployment
- Recommended Model: 2814744 (MCR-S10-50-UI-SW-DCI-NC)
- Key Reason: Combines medium-range adaptation, signal switching function, and no-calibration feature for complex working conditions
5. Large-Range On-Site Signal Conversion (e.g., 20-100mV/mA sensors)
- Requirement: Large-range signal conditioning, stable conversion
- Recommended Model: 2908798 (MCR-S-20-100-UI-DCI)
- Key Reason: Specifically designed for 20-100 large-range signals; high-precision conversion ensures signal reliability
Core Advantages
- Flexible Range Adaptation: Covers 1-5, 10-50, 20-100 ranges, compatible with on-site sensors of different specifications
- High-Precision Conversion: ±0.1% FS accuracy meets signal acquisition requirements for critical processes
- Plug-and-Play: NC (No Calibration) models are factory-pre-calibrated, ready for integration out of the box to improve deployment efficiency
- Rich Functions: Some models support signal switching (SW), suitable for multi-sensor collaborative work scenarios
- Stable & Reliable: Wide operating temperature range and high insulation strength resist industrial environmental interference
- Easy Installation: 35mm DIN rail mounting, compact design saves cabinet space
Installation & Usage Notes
- Rail Mounting: Install on 35mm DIN rail; reserve ≥5mm spacing between modules for heat dissipation
- Wiring Specifications: Use shielded cables to connect sensors and devices, reducing the impact of electromagnetic interference (EMI) on signals
- Power Supply Requirements: Connect to 12-30V DC power, ensuring correct polarity (built-in reverse polarity protection)
- Signal Matching: Ensure the input signal range matches the model’s marked range to avoid signal distortion
- Calibration Notes: NC models are factory-pre-calibrated and require no manual debugging; standard models can be custom-calibrated as needed