Phoenix QUINT-PS Series: Industrial Power Supplies - Selection Guide

Product Overview

The Phoenix QUINT-PS Series are high-reliability industrial switch-mode power supplies designed for stable power delivery in automation systems. Covering diverse input configurations (single-phase 100-240V AC, single-phase 230V AC, three-phase 400-500V AC) and output specifications (12V/24V/48V DC, 2.5A~40A), these supplies feature high efficiency, wide input voltage ranges, and robust protection mechanisms. With optional explosion-proof (EX) and specialized (F) variants, they’re ideal for general industrial environments, hazardous areas, and critical applications requiring uninterrupted, precise power.

Model Quick Reference Table

Model No. Product Name Input Type Output (Voltage/Current) Key Features Application Scenarios
2939467 QUINT-PS-3X400AC/24DC/20 Three-phase 400V AC 24V DC / 20A Three-phase input, high current Three-phase industrial systems, medium loads
2938222 QUINT-PS-3X400-500AC/48DC/20 Three-phase 400-500V AC 48V DC / 20A Wide three-phase input, 48V output High-voltage three-phase systems, 48V devices
2938219 QUINT-PS-3X400-500AC/48DC/10 Three-phase 400-500V AC 48V DC / 10A Compact three-phase 48V supply Medium-load 48V three-phase applications
2938594 QUINT-PS-3X400-500AC/24DC/5 Three-phase 400-500V AC 24V DC / 5A Low-current three-phase supply Light-load three-phase control systems
2938646 QUINT-PS-3X400-500AC/24DC/40 Three-phase 400-500V AC 24V DC / 40A High-power three-phase supply Heavy-load three-phase automation (e.g., multiple modules)
2939166 QUINT-PS-230AC/24DC/5 Single-phase 230V AC 24V DC / 5A Fixed 230V input, low current Local 230V AC systems, light loads
2939179 QUINT-PS-230AC/24DC/10 Single-phase 230V AC 24V DC / 10A Fixed 230V input, medium current Standard 230V AC industrial control
2939360 QUINT-PS-230AC/24DC/5/F Single-phase 230V AC 24V DC / 5A Special function (F), fixed input Custom 230V AC light-load applications
2939153 QUINT-PS-230AC/24DC/2,5 Single-phase 230V AC 24V DC / 2.5A Ultra-low current, fixed input Low-power 230V AC devices (sensors)
2866255 QUINT-PS-100-240AC/48DC/5 Single-phase 100-240V AC 48V DC / 5A Wide input, 48V low current Global 48V light-load systems
2938976 QUINT-PS-100-240AC/48DC/20 Single-phase 100-240V AC 48V DC / 20A Wide input, 48V high current Global 48V heavy-load devices
2938853 QUINT-PS-100-240AC/24DC/5/EX Single-phase 100-240V AC 24V DC / 5A Explosion-proof (EX), wide input Hazardous areas (Zone 2/22), light loads
2938879 QUINT-PS-100-240AC/24DC/40 Single-phase 100-240V AC 24V DC / 40A Wide input, ultra-high current Global heavy-load 24V systems
2938578 QUINT-PS-100-240AC/24DC/2.5 Single-phase 100-240V AC 24V DC / 2.5A Wide input, ultra-low current Global low-power 24V devices
2938866 QUINT-PS-100-240AC/24DC/10/EX Single-phase 100-240V AC 24V DC / 10A Explosion-proof (EX), wide input Hazardous areas, medium loads
2938811 QUINT-PS-100-240AC/12DC/10 Single-phase 100-240V AC 12V DC / 10A Wide input, 12V medium current Global 12V systems (e.g., low-voltage controllers)

Core Technical Specifications (Universal)

Parameter Value Notes
Input Voltage Ranges Single-phase: 100-240V AC / 230V AC; Three-phase: 400V AC / 400-500V AC Model-specific (see table)
Output Regulation ≤±1% (24V/48V models); ≤±2% (12V model) Precise voltage stability for sensitive devices
Efficiency Up to 95% (three-phase); Up to 94% (single-phase) Energy-saving, low heat generation
Operating Temperature -25℃~70℃ Adapts to harsh industrial environments
Protection Functions Overcurrent, overvoltage, short-circuit, overtemperature, reverse polarity Comprehensive device/supply protection
Mounting Type 35mm DIN rail (NS 35/7.5) Compact design, space-saving
Protection Class IP20 (cabinet mounting) Dust-proof, protects against solid objects ≥12mm
Power Factor Correction Active PFC (≥0.95 at full load) Reduces grid interference
Certifications CE, UL, CSA; EX models: ATEX/IECEx (Zone 2/22) Global industrial / hazardous area compliance
Connection Type Screw terminals / Push-in (model-dependent) Secure, tool-free or fixed wiring

Application Scenarios & Recommended Models

1. Global Single-Phase Systems (100-240V AC Input)

  • Requirement: 24V DC heavy loads (30-40A)

  • Recommended Model: 2938879 (QUINT-PS-100-240AC/24DC/40)

  • Key Reason: Ultra-high 40A output, wide input for global deployment

  • Requirement: 48V DC medium loads (10-20A)

  • Recommended Model: 2938976 (48DC/20) / 2938248 (48DC/10)

  • Key Reason: Wide input compatibility, 48V output for high-voltage devices

  • Requirement: Hazardous area (Zone 2/22) 24V DC loads

  • Recommended Model: 2938853 (5A/EX) / 2938866 (10A/EX)

  • Key Reason: EX certification for safe use in explosive environments

2. Fixed Single-Phase 230V AC Systems

  • Requirement: Standard 24V DC medium loads (10A)

  • Recommended Model: 2939179 (QUINT-PS-230AC/24DC/10)

  • Key Reason: Fixed 230V input, reliable for local industrial systems

  • Requirement: Low-power 24V DC devices (2.5A/5A)

  • Recommended Model: 2939153 (2.5A) / 2939166 (5A)

  • Key Reason: Compact, low-current design for sensors/controllers

3. Three-Phase Industrial Systems (400-500V AC Input)

  • Requirement: 24V DC heavy loads (30-40A)

  • Recommended Model: 2938646 (40A) / 2938633 (30A)

  • Key Reason: High-power three-phase input, supports multiple modules/heavy loads

  • Requirement: 48V DC medium loads (10-20A)

  • Recommended Model: 2938222 (20A) / 2938219 (10A)

  • Key Reason: Wide three-phase input, 48V output for specialized equipment

  • Requirement: 24V DC light loads (5A)

  • Recommended Model: 2938594 (QUINT-PS-3X400-500AC/24DC/5)

  • Key Reason: Low-current three-phase supply for light-load control systems

4. 12V DC Systems

  • Requirement: Global 12V DC medium loads (10A)
  • Recommended Model: 2938811 (QUINT-PS-100-240AC/12DC/10)
  • Key Reason: Wide input, 12V output for low-voltage controllers/actuators

Core Advantages

  • Diverse Input Adaptability: Covers single-phase (fixed/wide range) and three-phase inputs, matching global industrial power grids
  • High Power Density: Ultra-high current outputs (up to 40A) in compact DIN rail designs, saving cabinet space
  • Reliable Protection: Comprehensive safeguards (overcurrent/overvoltage/short-circuit) extend device lifespan
  • Hazardous Area Compatibility: EX models enable safe use in Zone 2/22 explosive environments
  • Energy Efficiency: Up to 95% efficiency reduces energy waste and heat generation
  • Global Compliance: CE/UL/CSA/ATEX certifications support international deployment

Installation & Usage Notes

  • Input Matching: Select single-phase/three-phase models based on the site’s power grid (e.g., three-phase for heavy loads)
  • Load Margin: Choose a supply with 20-30% current margin (e.g., 16A load → 20A model) to avoid overload
  • EX Model Installation: Follow ATEX/IECEx guidelines for hazardous area mounting (e.g., proper grounding)

Phoenix QUINT-PS Series: Industrial Power Supplies - Selection Guide