Phoenix PACT Series: Industrial Mounting Brackets, Current Sensors & Accessories - Selection Guide

Product Overview

The Phoenix PACT Series encompasses industrial mounting solutions, high-current sensors/transmitters, clamping fixtures, and signal conversion modules. Designed for industrial automation and power monitoring, the series includes customizable mounting brackets, 4000A high-current transducers (with/without PT100 temperature integration), secure clamping fixtures, and signal conditioning modules. Featuring robust construction, diverse size options, and compatibility with industrial control systems, these products support reliable current measurement, equipment installation, and signal conversion—ideal for power distribution, heavy machinery, and industrial process monitoring scenarios.

Model Quick Reference Table

Model No. Product Name Function Type Core Features Application Scenarios
2276638 PACT-FAST-MNT-W16-L40 Mounting Bracket Width 16mm, Length 40mm, fast-install Compact equipment mounting (space-constrained cabinets)
2276625 PACT-FAST-MNT-W13-L65 Mounting Bracket Width 13mm, Length 65mm, fast-install Medium-size device mounting
1382387 PACT SPC-100-1A-D13 Special Purpose Module 1A output, D13 size, specialized function Custom industrial control system integration
2904890 PACT RCP-D95 Size-Compatible Accessory D95 dimension matching Compatibility expansion for D95-sized PACT modules
2904892 PACT RCP-D190 Size-Compatible Accessory D190 dimension matching Compatibility expansion for D190-sized PACT modules
2907888 PACT RCP-CLAMP-5-10 Clamping Fixture 5-10mm clamping range Secure fixing of cables/pipes (5-10mm diameter)
2904895 PACT RCP-CLAMP Universal Clamping Fixture Adjustable clamping design General-purpose cable/pipe fixation in industrial setups
2906234 PACT RCP-4000A-UIRO-PT-D95 High-Current Transducer (with PT100) 4000A measurement, UI (Voltage/Current) output, PT100 temperature input, D95 size High-current + temperature monitoring (D95-sized installation)
2906235 PACT RCP-4000A-UIRO-PT-D140 High-Current Transducer (with PT100) 4000A measurement, UI output, PT100 input, D140 size High-current + temperature monitoring (D140-sized installation)
2906230 PACT RCP-4000A-UIRO-PT High-Current Transducer (with PT100) 4000A measurement, UI output, PT100 input Standalone high-current + temperature monitoring
2906231 PACT RCP-4000A-UIRO-D95 High-Current Transducer 4000A measurement, UI output, D95 size High-current monitoring (D95-sized installation)
2906233 PACT RCP-4000A-UIRO-D190 High-Current Transducer 4000A measurement, UI output, D190 size High-current monitoring (D190-sized installation)
2906232 PACT RCP-4000A-UIRO-D140 High-Current Transducer 4000A measurement, UI output, D140 size High-current monitoring (D140-sized installation)
2910326 PACT RCP-4000A-1A-D95-10M High-Current Transducer 4000A measurement, 1A output, D95 size, 10m cable High-current monitoring with extended cable (D95 size)
2904921 PACT RCP-4000A-1A-D95 High-Current Transducer 4000A measurement, 1A output, D95 size High-current monitoring (D95 size, 1A output)
2910327 PACT RCP-4000A-1A-D190-10M High-Current Transducer 4000A measurement, 1A output, D190 size, 10m cable High-current monitoring with extended cable (D190 size)
2904923 PACT RCP-4000A-1A-D190 High-Current Transducer 4000A measurement, 1A output, D190 size High-current monitoring (D190 size, 1A output)
2904922 PACT RCP-4000A-1A-D140 High-Current Transducer 4000A measurement, 1A output, D140 size High-current monitoring (D140 size, 1A output)
2902990 PACT RCP-4000A-1A High-Current Transducer 4000A measurement, 1A output Standalone high-current monitoring (1A output)
2277598 PACT MCR-RA Signal Conversion Module Signal conditioning/amplification Industrial signal refinement for control system integration

Core Technical Specifications (Universal)

Parameter Value Notes
Current Measurement Range Up to 4000A (RCP-4000A series) High-current focus for power monitoring
Output Signal Options UI (4-20mA/0-10V), 1A (transducer models) Standard signals for PLC/DCS integration
Temperature Input PT100/PT1000 (PT-suffixed models) Combined current + temperature monitoring
Mounting Compatibility 35mm DIN rail, bracket/clamp mounting Diverse installation options (size-dependent: D95/D140/D190)
Operating Temperature -25℃~70℃ Adaptable to harsh industrial environments
Measurement Accuracy ±1% FS (transducer models) Reliable high-current measurement
Supply Voltage 24V DC (20.4~28.8V, transducer models) Industrial standard power supply
Protection Class IP20 (module) / IP54 (clamp/bracket) Dust/water protection for installation components
Certifications CE, UL, CSA Global industrial compliance
Connection Type Screw terminals / Cable (10M models) Secure wiring for high-current applications

Application Scenarios & Recommended Models

1. High-Current Monitoring (Up to 4000A)

  • Requirement: Basic high-current measurement (1A output)

  • Recommended Models: 2902990 (standalone), 2904921 (D95), 2904923 (D190)

  • Key Reason: 4000A 量程适配大功率系统,1A 标准输出直接对接 PLC/DCS

  • Requirement: High-current + temperature monitoring

  • Recommended Models: 2906230 (standalone), 2906234 (D95), 2906235 (D140)

  • Key Reason: Integrated PT100 temperature input, simultaneous current/temperature data acquisition

  • Requirement: Extended cable for remote monitoring

  • Recommended Models: 2910326 (D95/10M), 2910327 (D190/10M)

  • Key Reason: 10m pre-installed cable enables remote mounting of transducers

2. Equipment Mounting (Custom Sizes)

  • Requirement: Compact space mounting (narrow width)

  • Recommended Model: 2276638 (PACT-FAST-MNT-W16-L40)

  • Key Reason: 16mm narrow width saves cabinet space for small devices

  • Requirement: Medium-size device mounting

  • Recommended Model: 2276625 (PACT-FAST-MNT-W13-L65)

  • Key Reason: 65mm length fits most standard industrial modules

3. Cable/Pipe Fixation

  • Requirement: Specific diameter (5-10mm) clamping

  • Recommended Model: 2907888 (PACT RCP-CLAMP-5-10)

  • Key Reason: Fixed 5-10mm range ensures secure fixation for standard cables/pipes

  • Requirement: Universal clamping (variable diameter)

  • Recommended Model: 2904895 (PACT RCP-CLAMP)

  • Key Reason: Adjustable design fits diverse cable/pipe sizes in industrial setups

4. Signal Conditioning & Compatibility Expansion

  • Requirement: Signal refinement for control systems

  • Recommended Model: 2277598 (PACT MCR-RA)

  • Key Reason: Signal conditioning/amplification improves compatibility with PLC/DCS

  • Requirement: Size-compatible accessory for PACT modules

  • Recommended Models: 2904890 (D95), 2904892 (D190)

  • Key Reason: Matches D-series module dimensions for seamless system expansion

Core Advantages

  • High-Current Expertise: RCP-4000A series supports up to 4000A measurement, ideal for heavy-industry power monitoring
  • Size Flexibility: D95/D140/D190 size options and custom mounting brackets fit diverse installation spaces
  • Multifunctional Integration: PT-suffixed models combine current measurement with temperature monitoring
  • Easy Installation: Fast-mount brackets, DIN rail compatibility, and pre-cabled (10M) options reduce deployment time
  • Industrial Reliability: Wide operating temperature range and robust protection ensure performance in harsh environments
  • Standardized Outputs: UI/1A signals enable direct integration with mainstream PLC/DCS systems

Installation & Usage Notes

  • Size Matching: Select D-series (D95/D140/D190) transducers/brackets based on cabinet space and installation requirements
  • High-Current Wiring: Use high-temperature, high-current-rated cables for transducer connections; ensure proper grounding
  • Clamping Torque: For clamp models, apply appropriate torque to avoid cable/pipe damage while ensuring secure fixation
  • Temperature Sensor Wiring: For PT-suffixed transducers, use shielded cables for PT100 connections to reduce interference
  • Cable Length: For 10M models, avoid excessive bending; maintain minimum bending radius (≥10× cable diameter)
  • Load Matching: Ensure transducer output (1A/UI) matches control system input requirements; add signal isolators if needed
  • Mounting Spacing: Reserve ≥10mm between transducers for heat dissipation (critical for high-current operation)

Phoenix PACT Series: Industrial Mounting Brackets, Current Sensors & Accessories - Selection Guide

Created on:2025-11-19 11:14

News Dynamics

NEWS