Phoenix MACX Series: Industrial Signal Conditioning & Monitoring Modules - Selection Guide

Product Overview

The Phoenix MACX Series encompasses high-performance signal conditioning, monitoring, and conversion modules designed for industrial automation. Covering precision signal isolation, voltage monitoring (DC/AC), temperature acquisition (TC/RTD), multiplexing, and relay output functions, these modules ensure reliable signal processing between field devices and control systems (PLC/DCS). Featuring compact DIN rail mounting (6.2mm width for SL sub-series), universal 24V DC power supply, and options for 免校准 (NC), pluggable terminals (SP), and precision isolation, the series excels in harsh industrial environments. Compliant with global standards (CE, UL, CSA), it’s ideal for process control, manufacturing, and critical applications requiring noise-free, accurate signal transmission.

Model Quick Reference Table

Model No. Product Name Function Type Core Features Application Scenarios
2904961 MACX PL-RPSSI-2I Precision Signal Isolator 2-channel, high-precision isolation Critical process signal isolation (e.g., pharmaceutical, aerospace)
2906243 MACX MCR-VDC-PT DC Voltage Monitoring (PT-Compatible) DC voltage measurement, PT signal integration DC power grid monitoring + potential transformer input
2906242 MACX MCR-VDC DC Voltage Monitoring Standard DC voltage detection Industrial DC power supply monitoring
2906244 MACX MCR-VAC-PT AC Voltage Monitoring (PT-Compatible) AC voltage measurement, PT signal integration AC power grid monitoring + potential transformer input
2906239 MACX MCR-VAC AC Voltage Monitoring Standard AC voltage detection Industrial AC power supply monitoring
1292339 MACX MCR-S-MUX-TB-1 Signal Multiplexer (Terminal Block) 1-channel multiplexing, terminal block design Compact single-channel signal consolidation
2308124 MACX MCR-S-MUX-TB Signal Multiplexer (Terminal Block) Multi-channel multiplexing, terminal block Control cabinet signal consolidation with terminal integration
2865599 MACX MCR-S-MUX Signal Multiplexer Multi-channel analog signal multiplexing Reduce PLC I/O modules via signal consolidation
2906170 MACX MCR-SL-UI-REL-SP UI-to-Relay Output Module 4-20mA/0-10V → relay output, pluggable (SP) Signal-triggered relay control + easy maintenance
2906169 MACX MCR-SL-UI-REL UI-to-Relay Output Module 4-20mA/0-10V → relay output, fixed terminals Standard signal-triggered relay control
2924346 MACX MCR-SL-TC-I-NC Thermocouple (TC) Input TC sensor compatibility, 免校准 (NC) Plug-and-play TC temperature monitoring
2924320 MACX MCR-SL-RTD-I-SP-NC RTD Input PT100/PT1000 compatibility, SP + NC Pluggable, calibration-free RTD temperature acquisition
2865078 MACX MCR-SL-RTD-I-NC RTD Input PT100/PT1000 compatibility, NC Standard calibration-free RTD monitoring
2924210 MACX MCR-SL-RPSSI-I-UP-SP Precision Signal Isolator (Upgraded) 1-channel, upgraded performance, SP High-precision signal isolation with pluggable terminals
2865968 MACX MCR-SL-RPSSI-I-UP Precision Signal Isolator (Upgraded) 1-channel, upgraded performance High-precision signal conditioning for sensitive sensors
2924207 MACX MCR-SL-RPSSI-I-SP Precision Signal Isolator 1-channel, SP terminals Standard precision signal isolation + easy wiring
2865955 MACX MCR-SL-RPSSI-I Precision Signal Isolator 1-channel, fixed terminals Basic high-precision signal isolation
2924838 MACX MCR-SL-RPSSI-2I-SP Precision Signal Isolator 2-channel, SP terminals Dual-channel high-precision isolation + maintenance ease
2924825 MACX MCR-SL-RPSSI-2I Precision Signal Isolator 2-channel, fixed terminals Dual-channel basic precision signal isolation
2904090 MACX MCR-SL-RPSS-2I-2I-SP Signal Isolator/Repeater 2-in/2-out, SP terminals Bidirectional dual-channel signal isolation/amplification
2904089 MACX MCR-SL-RPSS-2I-2I Signal Isolator/Repeater 2-in/2-out, fixed terminals Bidirectional dual-channel standard signal conditioning

Core Technical Specifications (Universal)

Parameter Value Notes
Supply Voltage 24V DC (19.2~30V DC) Universal industrial power supply
Isolation Voltage 3kV (input-output-supply) Anti-interference, protects control systems
Operating Temperature -25℃~70℃ Adaptable to harsh industrial environments
Mounting Type 35mm DIN rail (NS 35/7.5) 6.2mm width (SL sub-series) for space-saving
Terminal Type Fixed screw / Pluggable (SP models) SP models enable tool-free terminal replacement
Signal Compatibility 4-20mA, 0-10V, TC (J/K/T/etc.), RTD (PT100/PT1000), AC/DC voltage Covers mainstream industrial signals
Conversion Accuracy ≤±0.1% FS (precision models); ≤±0.2% FS (standard models) Meets critical/regular measurement needs
Response Time ≤1ms (signal isolation); ≤100ms (temperature modules) Fast signal processing for real-time control
Protection Class IP20 (cabinet mounting) Dust-proof, suitable for control cabinets
Certifications CE, UL, CSA, EN 61010-1 Global industrial compliance
Power Consumption ≤0.5W (single-channel); ≤1W (multi-channel) Low heat generation for dense mounting

Application Scenarios & Recommended Models

1. Precision Signal Isolation (Critical Processes)

  • Requirement: High-accuracy signal isolation for sensitive sensors
  • Recommended Models: 2924210 (RPSSI-I-UP-SP), 2904961 (PL-RPSSI-2I)
  • Key Reason: ≤±0.1% FS accuracy + 3kV isolation, ideal for pharmaceutical/ aerospace process control

2. Temperature Monitoring (TC/RTD Sensors)

  • Requirement: Calibration-free RTD/TC integration, pluggable terminals
  • Recommended Models: 2924320 (RTD-I-SP-NC), 2924346 (TC-I-NC)
  • Key Reason: NC (免校准) enables plug-and-play; SP terminals simplify maintenance

3. AC/DC Voltage Monitoring (Power Grids)

  • Requirement: PT-compatible voltage detection for industrial power supplies
  • Recommended Models: 2906243 (VDC-PT), 2906244 (VAC-PT)
  • Key Reason: Integrate with potential transformers for accurate grid voltage monitoring

4. Signal-Triggered Relay Control

  • Requirement: Convert UI signals to relay outputs for load switching
  • Recommended Models: 2906170 (UI-REL-SP), 2906169 (UI-REL)
  • Key Reason: 4-20mA/0-10V signal compatibility; SP models ease wiring updates

5. Signal Multiplexing (I/O Reduction)

  • Requirement: Consolidate multiple signals to reduce PLC I/O modules
  • Recommended Models: 2865599 (MCR-S-MUX), 2308124 (MCR-S-MUX-TB)
  • Key Reason: Multi-channel design lowers hardware costs; terminal block variants simplify wiring

6. Bidirectional Signal Conditioning

  • Requirement: 2-in/2-out signal isolation/amplification
  • Recommended Model: 2904090 (RPSS-2I-2I-SP)
  • Key Reason: Bidirectional functionality for two-way signal transmission between devices

Core Advantages

  • Dual Precision Tiers: Precision (≤±0.1% FS) and standard (≤±0.2% FS) models fit different accuracy needs
  • Plug-and-Play Convenience: NC (免校准) models eliminate manual calibration, reducing deployment time
  • Space-Saving Design: 6.2mm width (SL sub-series) maximizes dense control cabinet utilization
  • Flexible Terminals: SP (pluggable) and fixed terminals balance maintenance ease and cost-efficiency
  • Comprehensive Signal Support: Covers voltage, current, temperature, and multiplexing in one series
  • Industrial-Grade Reliability: 3kV isolation + wide temperature range resists interference and harsh conditions
  • Global Compatibility: CE/UL/CSA certifications enable international deployment

Installation & Usage Notes

  • Voltage Matching: Ensure supply voltage is 24V DC (19.2~30V DC); reverse polarity protection is built-in
  • Sensor Compatibility: For temperature modules, verify TC/RTD type matches module specifications (e.g., PT100 for RTD models)
  • Terminal Selection: Choose SP models for systems requiring frequent wiring changes; fixed terminals for cost-sensitive setups
  • Mounting Spacing: Reserve ≥3mm between SL sub-series modules; ≥5mm for multi-channel models to ensure heat dissipation
  • Wiring Specifications: Use shielded cables for signal lines to reduce EMI; separate power and signal wiring by ≥10mm
  • NC Model Usage: NC modules are factory-calibrated—avoid manual adjustment unless custom calibration is required
  • Relay Load Capacity: For UI-REL models, ensure load current/voltage does not exceed relay ratings (add 20% margin)

Phoenix MACX Series: Industrial Signal Conditioning & Monitoring Modules - Selection Guide