Phoenix FLT-SEC Series: Industrial Surge Protectors - Selection Guide
Product Overview
The Phoenix FLT-SEC Series are high-performance surge protectors (SPDs) designed for industrial power networks, featuring T1 (Type 1) single-stage and T1+T2 (Type 1+2) combined protection. Adopting 续流 - free discharge gap technology, they safeguard industrial equipment from transient surges (e.g., lightning, switching overvoltage) in harsh environments. Covering single-phase/three-phase networks, N/PE line protection, and supporting S-type (neutral-earth separated) and C-type (neutral-earth combined) wiring, these DIN-rail mountable modules offer visual status indicators, remote alarm contacts, and wide voltage compatibility (264V/350V/440V AC). Ideal for power distribution, manufacturing, and chemical plants, they ensure reliable operation of critical industrial systems.
Model Quick Reference Table
| Model No. | Product Name | Protection Type | Wiring Type | Rated Voltage (Uc) | Surge Current Rating | Key Features | Application Scenarios |
|---|---|---|---|---|---|---|---|
| 2905471 | FLT-SEC-T1-350/25-P | T1 (Type 1) | - | 350V AC | 25kA (10/350μs) | Screw terminal, single-stage protection | Single-phase industrial power primary surge protection |
| 2905470 | FLT-SEC-T1+T2-3S-350/25-FM | T1+T2 (Type 1+2) | S-type (Neutral-Earth Separated) | 350V AC | 25kA (8/20μs) | 3-phase protection, visual indicator + remote alarm | Three-phase industrial power comprehensive surge protection |
| 2905469 | FLT-SEC-T1+T2-3C-350/25-FM | T1+T2 (Type 1+2) | C-type (Neutral-Earth Combined) | 350V AC | 25kA (8/20μs) | Compact design, suitable for TN-C systems | Three-phase equipment centralized protection |
| 2905468 | FLT-SEC-T1+T2-2S-350/25-FM | T1+T2 (Type 1+2) | S-type | 350V AC | 25kA (8/20μs) | 2-phase protection, dual-stage suppression | Two-phase industrial network surge protection |
| 2905467 | FLT-SEC-T1+T2-2C-350/25-FM | T1+T2 (Type 1+2) | C-type | 350V AC | 25kA (8/20μs) | 2-phase compact design | Space-constrained two-phase system protection |
| 2905466 | FLT-SEC-T1+T2-1S-350/25-FM | T1+T2 (Type 1+2) | S-type | 350V AC | 25kA (8/20μs) | 1-phase protection, integrated T1+T2 | Single-phase sensitive equipment surge protection |
| 2905465 | FLT-SEC-T1+T2-1C-350/25-FM | T1+T2 (Type 1+2) | C-type | 350V AC | 25kA (8/20μs) | 1-phase cost-effective option | Basic single-phase power surge protection |
| 2907263 | FLT-SEC-P-T1-N/PE-440/100-P | T1 (Type 1) | N/PE Line | 440V AC | 100kA (8/20μs) | Screw terminal, N/PE line protection | Neutral/protective earth line surge suppression |
| 2907262 | FLT-SEC-P-T1-N/PE-440/100-FM | T1 (Type 1) | N/PE Line | 440V AC | 100kA (8/20μs) | Visual indicator + remote alarm | TN/TT system N/PE line surge protection |
| 2905473 | FLT-SEC-P-T1-N/PE-350/100-P | T1 (Type 1) | N/PE Line | 350V AC | 100kA (8/20μs) | Screw terminal, high-current capacity | Industrial grounding system surge protection |
| 2905472 | FLT-SEC-P-T1-N/PE-350/100-FM | T1 (Type 1) | N/PE Line | 350V AC | 100kA (8/20μs) | Fault alarm function | Critical equipment grounding surge protection |
| 2905989 | FLT-SEC-P-T1-440/35-P | T1 (Type 1) | - | 440V AC | 35kA (10/350μs) | High-voltage adaptation | High-voltage power system primary protection |
| 2908264 | FLT-SEC-P-T1-3S-440/35-FM | T1 (Type 1) | S-type | 440V AC | 35kA (10/350μs) | 3-phase high-voltage protection | Heavy industry high-voltage distribution system |
| 2905421 | FLT-SEC-P-T1-3S-350/25-FM | T1 (Type 1) | S-type | 350V AC | 25kA (10/350μs) | 3-phase redundant design | Three-phase power system enhanced protection |
| 2909589 | FLT-SEC-P-T1-3S-264/50-FM | T1 (Type 1) | S-type | 264V AC | 50kA (10/350μs) | Low-voltage high-current protection | Low-voltage three-phase heavy-load system |
| 2905988 | FLT-SEC-P-T1-3C-440/35-FM | T1 (Type 1) | C-type | 440V AC | 35kA (10/350μs) | 3-phase compact high-voltage | High-voltage TN-C system protection |
| 2905419 | FLT-SEC-P-T1-3C-350/25-FM | T1 (Type 1) | C-type | 350V AC | 25kA (10/350μs) | 3-phase cost-effective | Standard three-phase TN-C system protection |
| 2907390 | FLT-SEC-P-T1-3C-264/50-FM | T1 (Type 1) | C-type | 264V AC | 50kA (10/350μs) | Low-voltage high-current compact | Low-voltage dense cabinet three-phase protection |
Core Technical Specifications (Universal)
| Parameter | Value | Notes |
|---|---|---|
| Protection Classes | IEC Type 1 (T1), Type 1+2 (T1+T2) | Model-dependent |
| Rated Voltage (Uc) | 264V AC, 350V AC, 440V AC | Matches industrial power grids |
| Surge Current Ratings | 25kA/35kA/50kA/100kA | 10/350μs (T1); 8/20μs (T1+T2) |
| Voltage Protection Level (Up) | ≤1.5kV (typical) | Low residual voltage protects sensitive devices |
| Response Time | ≤25ns | Fast response to transient surges |
| Operating Temperature | -40℃~+80℃ | Adapts to harsh industrial environments |
| Mounting Type | 35mm DIN rail (NS 35/7.5) | Space-saving for cabinet installation |
| Connection Type | Screw terminals | Secure wiring (10~16mm² conductors) |
| Protection Features | Visual status indicator (green=normal, red=fault), remote alarm contacts (FM models) | Real-time monitoring of protection status |
| Protection Class | IP20 | Dust-proof for cabinet mounting |
| Certifications | IEC 61643-11, CE, UL, CSA | Global industrial compliance |
| Wiring Compatibility | S-type (TN-S/TT systems), C-type (TN-C systems) | Fits diverse power system topologies |
Application Scenarios & Recommended Models
1. Three-Phase Industrial Power Comprehensive Protection
- Requirement: 380V three-phase four-wire system, T1+T2 combined protection
- Recommended Models: 2905470 (S-type), 2905469 (C-type)
- Key Reason: Covers direct and induced lightning surges; S/C-type options fit different grounding systems
2. High-Voltage Power System Protection
- Requirement: 440V high-voltage input, 3-phase protection
- Recommended Models: 2908264 (3S-type), 2905989 (single-stage)
- Key Reason: High Uc (440V AC) and surge current capacity (35kA) handle high-voltage transients
3. N/PE Line Surge Suppression
- Requirement: Prevent ground potential 反击 in TN/TT systems
- Recommended Models: 2907263 (440V/100kA), 2905473 (350V/100kA)
- Key Reason: Dedicated N/PE line protection, 100kA high-current discharge capacity
4. Low-Voltage High-Current System Protection
- Requirement: 264V AC, three-phase heavy-load equipment
- Recommended Models: 2909589 (3S-type), 2907390 (3C-type)
- Key Reason: 50kA surge current rating, suitable for low-voltage high-load transients
5. Compact Cabinet Installation
- Requirement: Space-constrained control cabinets, 1/2-phase protection
- Recommended Models: 2905465 (1C-type), 2905467 (2C-type)
- Key Reason: Compact design, C-type wiring saves cabinet space
Core Advantages
- 续流 - Free Technology: T1-type discharge gap design eliminates power frequency 续流 risk, enhancing system reliability
- Flexible Wiring: S-type/C-type options adapt to TN-S/TN-C/TT power system topologies
- Intelligent Monitoring: FM models feature visual indicators and remote alarm contacts for real-time fault feedback
- Wide Voltage Compatibility: 264V/350V/440V AC options match global industrial power grids
- High Surge Capacity: Up to 100kA discharge current handles severe surge events
- Industrial-Grade Durability: -40℃~+80℃ operating temperature, IP20 protection resists harsh environments
- Easy Installation: DIN rail mounting and screw terminals simplify on-site deployment
Installation & Usage Notes
- Wiring Matching: Select S-type for TN-S/TT systems (neutral-earth separated) and C-type for TN-C systems (neutral-earth combined)
- Voltage Selection: Uc must exceed the system's maximum continuous operating voltage by 10-15% (e.g., 380V system → 350V AC model)
- Wiring Specifications: Use 10~16mm² copper conductors; keep connection lines ≤0.5m to minimize impedance
- Mounting Position: Install as close to the power input terminal as possible (primary protection) or near sensitive equipment (secondary protection)
- Maintenance Checks: Regularly inspect status indicators (green=normal, red=fault); replace faulty modules promptly
- Alarm Wiring: Connect FM model remote alarm contacts to the control system for centralized monitoring
- Parallel Installation: Do not connect surge protectors in series; parallel installation only for redundant protection