Phoenix QUINT Series: Power Redundancy, UPS & Buffer Modules - Selection Guide
Product Overview
The Phoenix QUINT Series includes high-reliability power redundancy modules, UPS systems, buffer modules, and diode rectifiers, designed to ensure uninterrupted power supply for industrial automation systems. Covering AC/DC UPS (120/230V AC input), DC redundancy (ORING/DIODE modules), DC-UPS (24/48V DC), and buffer modules, these products support high current ratings (up to 80A), redundant power configuration, and seamless switchover. With industrial-grade durability, wide temperature adaptation, and DIN rail mounting, they’re ideal for critical applications like PLCs, sensors, and control systems in manufacturing, process control, and power distribution—protecting against power outages, voltage fluctuations, and transient interruptions.
Model Quick Reference Table
| Model No. | Product Name | Product Type | Input Specifications | Output Specifications | Core Features | Application Scenarios |
|---|---|---|---|---|---|---|
| 2902879 | QUINT-ORING/24DC/2X40/1X80 | Power Redundancy Module | 2×24V DC (40A each) | 24V DC (80A) | ORING redundancy, dual input → single output | Industrial 24V DC power redundancy (high-current loads) |
| 2320186 | QUINT-ORING/24DC/2X20/1X40 | Power Redundancy Module | 2×24V DC (20A each) | 24V DC (40A) | Medium-current redundancy, compact design | Standard 24V DC redundant power systems |
| 2320173 | QUINT-ORING/24DC/2X10/1X20 | Power Redundancy Module | 2×24V DC (10A each) | 24V DC (20A) | Low-current redundancy, space-saving | Small-scale 24V DC device redundancy |
| 1136815 | QUINT-HP-UPS/230AC/2.5KVA/PT | AC UPS System | 230V AC | 230V AC (2.5KVA) | PT-compatible, online UPS | Critical AC equipment (servers, controllers) uninterrupted power |
| 1136811 | QUINT-HP-UPS/230AC/1.5KVA/PT | AC UPS System | 230V AC | 230V AC (1.5KVA) | Compact AC UPS, PT integration | Standard AC device backup power |
| 1136813 | QUINT-HP-UPS/120AC/2.5KVA/PT | AC UPS System | 120V AC | 120V AC (2.5KVA) | 120V AC 适配,high power | North American grid AC equipment UPS |
| 1136804 | QUINT-HP-UPS/120AC/1.5KVA/PT | AC UPS System | 120V AC | 120V AC (1.5KVA) | Medium-power 120V UPS | Standard 120V AC device backup |
| 1133819 | QUINT-HP-BAT/PB/48DC/7.0AH/PT | UPS Battery Module | 48V DC (charging) | 48V DC (7.0AH) | Lead-acid battery, PT-compatible | Backup for QUINT-HP-UPS 48V systems |
| 2866585 | QUINT-DIODE/48DC/40 | Diode Rectifier Module | 48V DC | 48V DC (40A) | Single-channel diode rectifier | 48V DC power rectification/protection |
| 2320160 | QUINT-DIODE/48DC/2X20/1X40 | Diode Redundancy Module | 2×48V DC (20A each) | 48V DC (40A) | Dual-input diode redundancy | 48V DC redundant power supply |
| 2938963 | QUINT-DIODE/40 | Diode Rectifier Module | Universal DC | DC (40A) | General-purpose high-current diode | Industrial DC power rectification |
| 2320157 | QUINT-DIODE/12-24DC/2X20/1X40 | Diode Redundancy Module | 2×12-24V DC (20A each) | 12-24V DC (40A) | Wide input voltage, dual redundancy | 12-24V DC variable-voltage redundancy |
| 2866242 | QUINT-DC-UPS/24DC/40 | DC UPS System | 24V DC | 24V DC (40A) | High-current DC UPS | Heavy-load 24V DC device backup (motors, valves) |
| 2866239 | QUINT-DC-UPS/24DC/20 | DC UPS System | 24V DC | 24V DC (20A) | Medium-current DC UPS | Standard 24V DC control system backup |
| 2866226 | QUINT-DC-UPS/24DC/10 | DC UPS System | 24V DC | 24V DC (10A) | Low-current DC UPS | Light-load 24V DC device (sensors) backup |
| 2320393 | QUINT-BUFFER/24DC/24DC/40 | Power Buffer Module | 24V DC | 24V DC (40A) | Transient power buffer | Protect against short-term power interruptions |
| 2866213 | QUINT-BUFFER/24DC/20 | Power Buffer Module | 24V DC | 24V DC (20A) | Compact buffer module | Standard 24V DC device transient protection |
Core Technical Specifications (Universal)
| Parameter | Value | Notes |
|---|---|---|
| Supply Voltage Range | DC: 12-48V DC; AC: 100-240V AC (HP-UPS) | Model-dependent voltage adaptation |
| Output Current Rating | 10A~80A (module-dependent) | High-current support for heavy loads |
| Operating Temperature | -25℃~70℃ | Adaptable to harsh industrial environments |
| Mounting Type | 35mm DIN rail (NS 35/7.5) | Standard industrial cabinet installation |
| Protection Functions | Overcurrent, overvoltage, short-circuit, overtemperature | Comprehensive power protection |
| Switchover Time | ≤1ms (redundancy/UPS modules) | Seamless switchover, no power interruption |
| Battery Compatibility | Lead-acid (AGM/GEL) (UPS models) | Maintenance-free battery support |
| Connection Type | Screw terminals / Push-in terminals | Secure wiring (0.5~4mm² conductors) |
| Efficiency | Up to 96% (redundancy modules) | Energy-saving operation |
| Protection Class | IP20 (cabinet mounting) | Dust-proof for industrial use |
| Certifications | CE, UL, CSA, IEC 62040 | Global industrial compliance |
Application Scenarios & Recommended Models
1. Industrial Power Redundancy Systems
-
Requirement: 24V DC high-current (≥40A) redundant power supply
-
Recommended Model: 2902879 (QUINT-ORING/24DC/2X40/1X80)
-
Key Reason: Dual 40A input → 80A output, ORING redundancy ensures continuous power if one input fails
-
Requirement: 48V DC redundant power for medium loads
-
Recommended Model: 2320160 (QUINT-DIODE/48DC/2X20/1X40)
-
Key Reason: Diode-based redundancy, prevents reverse current, fits 48V DC systems
2. Critical AC Equipment Uninterrupted Power
-
Requirement: 230V AC high-power (2.5KVA) UPS for servers/controllers
-
Recommended Model: 1136815 (QUINT-HP-UPS/230AC/2.5KVA/PT)
-
Key Reason: PT-compatible, online UPS design, stable output for sensitive AC equipment
-
Requirement: 120V AC standard-load (1.5KVA) backup
-
Recommended Model: 1136804 (QUINT-HP-UPS/120AC/1.5KVA/PT)
-
Key Reason: 适配 North American 120V grid, reliable backup for office/industrial AC devices
3. DC Device Long-Term Backup
-
Requirement: 24V DC heavy-load (40A) backup for motors/valves
-
Recommended Model: 2866242 (QUINT-DC-UPS/24DC/40)
-
Key Reason: 40A high output, supports long-term backup for power-hungry DC devices
-
Requirement: 48V DC UPS battery backup
-
Recommended Model: 1133819 (QUINT-HP-BAT/48DC/7.0AH/PT)
-
Key Reason: 7.0AH capacity, lead-acid AGM technology, matches QUINT-HP-UPS 48V systems
4. Transient Power Interruption Protection
- Requirement: 24V DC buffer for short-term power cuts (e.g., PLCs)
- Recommended Models: 2320393 (40A), 2866213 (20A)
- Key Reason: ≤1ms response, buffers voltage dips/short outages to protect sensitive electronics
Core Advantages
- Redundancy & Backup: ORING/diode redundancy and UPS systems eliminate single points of failure
- High Current Capacity: Up to 80A output supports heavy industrial loads
- Seamless Switchover: ≤1ms switchover time ensures no power interruption for critical devices
- Wide Voltage Adaptation: Covers 12-48V DC and 120/230V AC, matching global power grids
- Industrial-Grade Durability: -25℃~70℃ operating temperature, robust protection against harsh conditions
- Easy Integration: DIN rail mounting and standard terminals simplify cabinet installation
- Battery Compatibility: Supports maintenance-free lead-acid batteries for long backup durations
Installation & Usage Notes
- Voltage Matching: Ensure input/output voltage matches the module’s rating (e.g., 24V DC modules for 24V systems)
- Redundancy Configuration: For ORING/diode modules, use identical power supplies for dual inputs to ensure compatibility
- Battery Maintenance: Charge UPS batteries every 3-6 months; store at 0-40℃ to extend lifespan
- Heat Dissipation: Reserve ≥10mm space between modules, especially for high-current (40A+) models
- Wiring Specifications: Use 0.5~4mm² conductors based on current; tighten terminals to prevent voltage drop
- UPS Setup: For AC UPS models, connect PT signals (if needed) for enhanced monitoring and control
- Buffer Module Placement: Install buffer modules close to sensitive devices (e.g., PLCs) to minimize wire length and voltage loss