Phoenix PLC-RSC Series: Industrial Interface Relay Modules - Selection Guide

Product Overview

The Phoenix PLC-RSC Series are industrial-grade interface relay modules designed to bridge PLC outputs with external devices in automation systems. Supporting a wide range of input voltages (5V DC~230V AC, including 24V AC/DC universal input), diverse contact configurations (1CO/2CO), and functional features (gold-plated contacts, high-capacity, explosion-proof, manual operation), these modules provide reliable electrical isolation, signal conversion, and load protection. With robust construction, 35mm DIN rail mounting, and compatibility with industrial control systems, they’re ideal for machine control, process automation, and safety-related circuits—especially in scenarios requiring adaptation to multiple voltage domains and load types.

Model Quick Reference Table

Model No. Product Name Input Voltage Contact Configuration Key Features Application Scenarios
2966142 PLC-RSC-60DC/21AU 60V DC 1 Changeover Contact (1CO) Gold-plated (AU, low-level signal compatible) Precision sensor/signaling device switching
2966126 PLC-RSC-48DC/21AU 48V DC 1CO Gold-plated (AU) 48V DC system low-voltage signal control
2966278 PLC-RSC-24UC/21AU 24V AC/DC (Universal) 1CO Gold-plated (AU), universal input Mixed 24V AC/DC system precision signal switching
1079402 PLC-RSC-230AC/21HC/SO46/HI 230V AC 1CO High-capacity (HC, 10A), SO46 terminal, HI function 230V AC high-power load control (solenoid valves, small motors)
1079387 PLC-RSC-230AC/21-21/SO46/HI 230V AC 2 Changeover Contacts (2CO) SO46 terminal, HI function, dual channels 230V AC dual-channel load control
2987286 PLC-RSC-220DC/21AU 220V DC 1CO Gold-plated (AU) High-voltage DC system low-level signal switching
2966919 PLC-RSC-12DC/21AU 12V DC 1CO Gold-plated (AU) 12V DC sensor/electronic component control
2909517 PLC-RSC-12DC/21-21/EX 12V DC 2CO Explosion-proof (EX) Hazardous area dual-channel switching
2980021 PLC-RSC-125DC/21 125V DC 1CO Standard configuration High-voltage DC industrial equipment control
2967293 PLC-RSC-60DC/21-21 60V DC 2CO Dual-channel standard design 60V DC dual-load control
2966139 PLC-RSC-60DC/21 60V DC 1CO Standard configuration 60V DC single-load switching
1119897 PLC-RSC-5DC/21 5V DC 1CO Low-voltage input Microcontroller/PLC low-voltage signal interface
2967646 PLC-RSC-48DC/21HC 48V DC 1CO High-capacity (HC, 10A) 48V DC high-power load control
2967280 PLC-RSC-48DC/21-21AU 48V DC 2CO Gold-plated (AU) 48V DC dual-channel precision signal control
2910504 PLC-RSC-48DC/21-21/MS 48V DC 2CO Manual Operation (MS) 48V DC dual-load control + on-site debugging
2967248 PLC-RSC-48DC/21-21 48V DC 2CO Standard configuration 48V DC general dual-channel control
2966113 PLC-RSC-48DC/21 48V DC 1CO Standard configuration 48V DC single-load general control

Core Technical Specifications (Universal)

Parameter Value Notes
Input Voltage Range DC: 4~137.5V (5DC~125DC); AC: 198~253V (230AC); 24UC: 19.2~28.8V DC/19.2~26.4V AC Wide voltage adaptation for diverse systems
Contact Configuration 1CO (21), 2CO (21-21) Changeover contacts (NO+NC) for flexible control
Contact Materials AgNi (standard); AgSnO (HC); Gold-plated AgNi (AU) Match load type (high-power/low-level)
Maximum Switching Capacity Standard/AU: 250V AC/6A, 24V DC/3A; HC: 250V AC/10A, 24V DC/5A Load-dependent rating
Response Time 3~15ms Fast switching for high-speed control
Mechanical Life 5×10⁶~3×10⁷ operations High reliability, low maintenance
Insulation Strength 4kV (coil-contact) Anti-interference, protects PLC circuits
Mounting Type 35mm DIN rail (NS 35/7.5) Compact, zero-spacing arrangement
Protection Class IP20 (base); RTIII (relay) Dust-proof, cabinet-mounted
Operating Temperature -40℃~70℃ Adapt to extreme industrial environments
Connection Type Screw terminals (SO46 for specific models) Secure wiring (0.14~2.5mm² wires)
Certifications CE, UL, CSA Global industrial compliance

Application Scenarios & Recommended Models

1. High-Power Load Control (≤10A)

  • Requirement: 230V AC/48V DC high-current loads (solenoid valves, small motors)
  • Recommended Models: 1079402 (230AC/21HC), 2967646 (48DC/21HC)
  • Key Reason: AgSnO HC contacts handle 10A loads; compatible with high-voltage AC/DC systems

2. Low-Level/Sensitive Signal Switching

  • Requirement: Precision sensor or measuring equipment signal control
  • Recommended Models: 2966142 (60DC/21AU), 2966278 (24UC/21AU)
  • Key Reason: Gold-plated (AU) contacts reduce contact resistance, ideal for low-voltage sensitive signals

3. Hazardous Area Applications

  • Requirement: Explosion-proof dual-channel switching in dangerous zones
  • Recommended Model: 2909517 (PLC-RSC-12DC/21-21/EX)
  • Key Reason: EX certification ensures safe operation in chemical plants, oil refineries

4. On-Site Debugging & Maintenance

  • Requirement: Manual operation for testing without PLC signals
  • Recommended Model: 2910504 (PLC-RSC-48DC/21-21/MS)
  • Key Reason: MS (Manual Operation) function simplifies on-site troubleshooting

5. Dual-Channel Control Systems

  • Requirement: 230AC/48DC dual-load simultaneous control
  • Recommended Models: 1079387 (230AC/21-21), 2967248 (48DC/21-21)
  • Key Reason: 2CO contacts support two independent load circuits; standard configuration for general automation

6. High-Voltage DC System Control

  • Requirement: 125V DC/220V DC industrial equipment switching
  • Recommended Models: 2980021 (125DC/21), 2987286 (220DC/21AU)
  • Key Reason: Wide input voltage tolerance adapts to high-voltage DC power grids

Core Advantages

  • Wide Voltage Compatibility: Covers 5V DC~230V AC (including 24V AC/DC universal input) for diverse industrial systems
  • Diverse Contact Options: Standard/HC/AU contacts fit high-power, low-level, and precision applications
  • Functional Versatility: Supports explosion-proof (EX) and manual operation (MS) for special needs
  • Industrial-Grade Durability: -40℃~70℃ operating temperature and 4kV insulation strength resist harsh environments
  • Easy Installation: DIN rail mounting and secure screw terminals simplify cabinet layout
  • Global Compliance: CE/UL/CSA certifications enable international deployment

Installation & Usage Notes

  • Voltage Matching: Ensure input voltage aligns with module ratings (e.g., 24UC models for mixed 24V AC/DC; 220DC models avoid AC input)
  • Load Matching: Select HC models for >6A loads, AU models for <50mA low-level signals, and standard models for general loads
  • EX Model Installation: Deploy 2909517 in compliance with ATEX/IECEx standards (proper grounding, zone restrictions)
  • MS Function Use: Use manual operation only for debugging; avoid long-term manual activation to prevent contact wear
  • Wiring Care: Strip wires to 10mm for full insertion into terminals; use shielded cables in EMI-prone environments
  • High-Voltage Caution: For 125DC/220DC models, use high-voltage-rated cables and ensure proper insulation to avoid arcing
  • Mounting Spacing: Reserve ≥5mm between modules for heat dissipation, especially for HC high-current models

Phoenix PLC-RSC Series: Industrial Interface Relay Modules - Selection Guide

Created on:2025-11-20 12:54

News Dynamics

NEWS