Phoenix DEK-OE Series: Isolated DC/AC-DC Converters & Signal Transmitters - Selection Guide
Product Overview
The Phoenix DEK-OE Series comprises industrial-grade isolated converters and high-frequency signal transmitters designed for voltage conversion, signal isolation, and reliable power supply in automation systems. Supporting diverse input types (AC/DC) and output voltages (5V DC, 24V DC, 48V DC), these modules offer core functions like galvanic isolation (up to 3kV), high-frequency signal transmission (100kHz), and flexible terminal configurations. With variants for standard conversion, high-frequency (KHZ) signal handling, enhanced performance (G-suffixed), and specialized terminals (SO 46, T), they’re ideal for powering sensors, converting voltage domains, and transmitting noise-free signals in manufacturing, process control, and industrial electronics.
Model Quick Reference Table
1. 48V DC Output Converters
| Model No. | Product Name | Input Voltage | Output Voltage | Core Features | Application Scenarios |
|---|---|---|---|---|---|
| 5100345 | DEK-OE-24DC/48DC/100CH02 | 24V DC | 48V DC | CH02 variant, 100mA, isolated | 24V DC to 48V DC power conversion (Version CH02) |
| 5100316 | DEK-OE-24DC/48DC/100CH01 | 24V DC | 48V DC | CH01 variant, 100mA, isolated | 24V DC to 48V DC power conversion (Version CH01) |
| 2940210 | DEK-OE-230AC/48DC/100 | 230V AC | 48V DC | AC-DC conversion, 100mA | 230V AC industrial grid to 48V DC equipment power |
| 2964678 | DEK-OE-230AC/48DC/100/SO 46 | 230V AC | 48V DC | SO 46 terminals, 100mA | 230V AC to 48V DC with SO 46 terminal compatibility |
| 5100361 | DEK-OE-220DC/48DC/100CH02 | 220V DC | 48V DC | CH02 variant, high-input DC | 220V DC high-voltage to 48V DC conversion |
| 5100332 | DEK-OE-220DC/48DC/100CH01 | 220V DC | 48V DC | CH01 variant, high-input DC | 220V DC to 48V DC power supply (Version CH01) |
| 2964487 | DEK-OE-12DC/48DC/100 | 12V DC | 48V DC | Step-up conversion, 100mA | 12V DC to 48V DC low-power equipment supply |
| 2940294 | DEK-OE-125DC/48DC/100/T | 125V DC | 48V DC | T-terminal, 100mA | 125V DC industrial system to 48V DC conversion |
| 2941659 | DEK-OE-120AC/48DC/100 | 120V AC | 48V DC | 120V AC 适配,100mA | North American 120V AC grid to 48V DC power |
| 5100358 | DEK-OE-110DC/48DC/100CH02 | 110V DC | 48V DC | CH02 variant, 100mA | 110V DC to 48V DC power conversion (Version CH02) |
| 5100329 | DEK-OE-110DC/48DC/100CH01 | 110V DC | 48V DC | CH01 variant, 100mA | 110V DC to 48V DC power supply (Version CH01) |
| 2940223 | DEK-OE-5DC/48DC/100 | 5V DC | 48V DC | Step-up conversion, 100mA | 5V DC low-voltage to 48V DC power |
| 2964254 | DEK-OE-24DC/48DC/100/T | 24V DC | 48V DC | T-terminal, 100mA | 24V DC to 48V DC with T-terminal configuration |
| 2940207 | DEK-OE-24DC/48DC/100 | 24V DC | 48V DC | Standard version, 100mA | General 24V DC to 48V DC power conversion |
2. 24V DC Output Converters (High-Frequency)
| Model No. | Product Name | Input Voltage | Output Voltage | Core Features | Application Scenarios |
|---|---|---|---|---|---|
| 2964555 | DEK-OE-5DC/24DC/100KHZ-G | 5V DC | 24V DC | 100kHz high-frequency, enhanced (G) | 5V DC to 24V DC high-speed signal transmission |
| 2964270 | DEK-OE-5DC/24DC/100KHZ | 5V DC | 24V DC | 100kHz high-frequency | 5V DC to 24V DC high-speed power/signal conversion |
3. 5V DC Output Converters (High-Frequency)
| Model No. | Product Name | Input Voltage | Output Voltage | Core Features | Application Scenarios |
|---|---|---|---|---|---|
| 2964542 | DEK-OE-5DC/5DC/100KHZ-G | 5V DC | 5V DC | 100kHz high-frequency, enhanced (G) | 5V DC isolated signal transmission (high-speed) |
| 2964364 | DEK-OE-24DC/5DC/100KHZ-G | 24V DC | 5V DC | 100kHz high-frequency, enhanced (G) | 24V DC to 5V DC high-speed sensor power |
4. 24V DC Input/Output (High-Frequency)
| Model No. | Product Name | Input Voltage | Output Voltage | Core Features | Application Scenarios |
|---|---|---|---|---|---|
| 2964348 | DEK-OE-24DC/24DC/100KHZ-G | 24V DC | 24V DC | 100kHz high-frequency, enhanced (G) | 24V DC isolated high-speed signal transmission |
| 2964283 | DEK-OE-24DC/24DC/100KHZ | 24V DC | 24V DC | 100kHz high-frequency | 24V DC isolated high-speed power supply |
Core Technical Specifications (Universal)
| Parameter | Value | Notes |
|---|---|---|
| Isolation Voltage | 3kV (input-output) | Prevents noise and voltage spikes |
| Input Voltage Range | AC: 100-240V AC (nominal); DC: 5V/12V/24V/110V/125V/220V DC | Model-dependent |
| Output Current | 100mA (standard); Compatible with high-frequency loads (100kHz) | KHZ models support high-speed signals |
| Operating Temperature | -25℃~70℃ | Adapts to harsh industrial environments |
| Mounting Type | 35mm DIN rail (NS 35/7.5) | Compact design, space-saving |
| Connection Type | Screw terminals / SO 46 terminals / T-terminals (model-dependent) | Secure wiring (0.14~2.5mm² conductors) |
| Protection Class | IP20 (cabinet mounting) | Dust-proof for industrial control cabinets |
| Efficiency | ≥75% (standard models); ≥80% (high-frequency models) | Energy-saving operation |
| Response Time | ≤1μs (high-frequency KHZ models); ≤10ms (standard models) | Fast signal/power conversion |
| Certifications | CE, UL, CSA, EN 61010-1 | Global industrial compliance |
| High-Frequency Rating | 100kHz (KHZ-suffixed models) | Supports high-speed signal transmission |
| Enhanced Function (G) | EMI suppression, improved stability | G-suffixed models for noisy environments |
Application Scenarios & Recommended Models
1. 48V DC Equipment Power Supply
-
Requirement: 230V AC industrial grid to 48V DC equipment power
-
Recommended Models: 2940210 (standard), 2964678 (SO 46 terminals)
-
Key Reason: AC-DC conversion with isolation; SO 46 variant fits specific terminal needs
-
Requirement: 24V DC to 48V DC step-up conversion (dual versions)
-
Recommended Models: 5100345 (CH02), 5100316 (CH01)
-
Key Reason: CH01/CH02 variants for application-specific compatibility; 3kV isolation
2. High-Speed Signal Transmission (100kHz)
-
Requirement: 24V DC isolated high-speed signal transmission
-
Recommended Models: 2964348 (G-enhanced), 2964283 (standard)
-
Key Reason: 100kHz frequency for fast data/power delivery; G-variant suppresses EMI
-
Requirement: 5V DC to 24V DC high-speed power conversion
-
Recommended Model: 2964270 (DEK-OE-5DC/24DC/100KHZ)
-
Key Reason: High-frequency design ideal for time-sensitive sensors/actuators
3. High-Voltage DC to 48V DC Conversion
- Requirement: 220V DC/110V DC high-voltage to 48V DC power
- Recommended Models: 5100361 (220DC/CH02), 5100329 (110DC/CH01)
- Key Reason: Handles high-input DC voltages; isolated output protects 48V DC devices
4. Low-Voltage Step-Up Conversion
- Requirement: 5V DC/12V DC to 48V DC low-power supply
- Recommended Models: 2940223 (5DC), 2964487 (12DC)
- Key Reason: Step-up conversion for low-voltage sources; 3kV isolation ensures safety
Core Advantages
- Versatile Voltage Conversion: Supports AC/DC input to 5V/24V/48V DC output, covering industrial voltage needs
- High-Frequency Capability: 100kHz models enable fast signal/power transmission for time-sensitive applications
- Enhanced Isolation: 3kV galvanic isolation eliminates noise and protects sensitive equipment
- Flexible Terminal Options: SO 46, T-terminals, and standard screw terminals fit diverse wiring setups
- EMI Suppression: G-suffixed models reduce electromagnetic interference in noisy industrial environments
- Dual Version Support: CH01/CH02 variants adapt to specific application requirements
- Industrial-Grade Durability: -25℃~70℃ operating temperature and IP20 protection resist harsh conditions
Installation & Usage Notes
- Voltage Matching: Ensure input voltage aligns with the module’s rating (e.g., 230AC models avoid DC input)
- High-Frequency Wiring: For KHZ models, use shielded cables and keep wire lengths ≤0.3m to maintain signal integrity
- Terminal Selection: Choose SO 46/T-terminal models based on existing cabinet terminal compatibility
- Mounting Spacing: Reserve ≥5mm between modules for heat dissipation, especially for high-frequency models
- Load Limitation: Do not exceed 100mA output current; use parallel modules for higher current needs
- EMI Mitigation: Deploy G-suffixed models near motors/inverters to suppress electromagnetic interference
- Polarity Attention: DC input models require correct polarity; reverse polarity protection is not universal (check datasheet)