Phoenix Contact SUBCON-PLUS Series: Industrial Bus Connectors & Adapters - Selection Guide
Product Overview
The SUBCON-PLUS Series comprises industrial-grade bus connectors, adapters, and accessories designed for reliable signal transmission in industrial networks. Supporting key bus protocols (PROFIBUS, CAN, ARCNET), these products feature robust construction, flexible mounting options, and standardized interfaces—enabling seamless connection between bus devices, controllers, and field equipment. Ideal for manufacturing automation, process control, and industrial communication systems, they ensure stable and interference-free bus communication in harsh industrial environments.
Model Quick Reference Table
1. PROFIBUS & General Bus Accessories
| Model No. |
Product Name |
Bus Protocol |
Core Features |
Application Scenarios |
| 2799694 |
SUBCON-SHORT-SCREW |
Universal |
Screw-type shorting accessory |
Bus line shorting, termination, or fixed connection |
| 2744348 |
SUBCON-PLUS-PROFIB |
PROFIBUS |
PROFIBUS-compatible connector |
Industrial PROFIBUS network device connection |
2. CAN Bus Connectors & Adapters
| Model No. |
Product Name |
Bus Protocol |
Core Features |
Application Scenarios |
| 2904467 |
SUBCON-PLUS-M/AX 9 |
CAN |
Male connector, AX 9 configuration |
CAN bus male-female device interconnection |
| 2311797 |
SUBCON-PLUS-F/AX 9 |
CAN |
Female connector, AX 9 configuration |
CAN bus controller/module female interface connection |
| 2708999 |
SUBCON-PLUS-CAN/SC2 |
CAN |
SC2 terminal interface |
CAN bus signal termination and connection |
| 2708119 |
SUBCON-PLUS-CAN/PG |
CAN |
PG-style connector |
CAN bus programming device or controller connection |
| 2902326 |
SUBCON-PLUS-CAN/AX/M12 |
CAN |
AX + M12 dual interface |
CAN bus device connection with M12 rugged interface |
| 2306566 |
SUBCON-PLUS-CAN/AX |
CAN |
AX standard interface |
Standard CAN bus module/device interconnection |
| 2902731 |
SUBCON-PLUS-CAN/90X/M12 |
CAN |
90° angled, M12 interface |
Space-constrained CAN bus installations (right-angle connection) |
| 2902322 |
SUBCON-PLUS-CAN/90/PG/M12 |
CAN |
90° angled, PG + M12 interface |
Angled connection for CAN bus with PG/M12 device compatibility |
| 2902323 |
SUBCON-PLUS-CAN/90/M12 |
CAN |
90° angled, M12 interface |
Compact CAN bus rugged connection (angled) |
| 2902325 |
SUBCON-PLUS-CAN/35/M12 |
CAN |
35° angled, M12 interface |
Low-profile angled CAN bus M12 connection |
| 2744694 |
SUBCON-PLUS-CAN |
CAN |
Standard CAN connector |
General CAN bus device interconnection |
3. ARCNET Bus Adapter
| Model No. |
Product Name |
Bus Protocol |
Core Features |
Application Scenarios |
| 2903271 |
SUBCON-PLUS-ARCNET/AX/SC038 |
ARCNET |
AX + SC038 interface |
ARCNET industrial network device connection |
4. Combined CAN/AX Adapter
| Model No. |
Product Name |
Bus Protocol |
Core Features |
Application Scenarios |
| 2306524 |
SUBCON-PLUS/AX/CAN/SO144 |
CAN + AX |
AX/CAN dual protocol, SO144 terminal |
Multi-protocol compatibility for CAN/AX hybrid systems |
Core Technical Specifications (Universal)
| Parameter |
Value |
Notes |
| Bus Compatibility |
PROFIBUS, CAN, ARCNET (model-dependent) |
Supports industry-standard bus protocols |
| Operating Temperature |
-25℃~70℃ |
Adapts to harsh industrial environments |
| Mounting Type |
35mm DIN rail, panel-mount, or cable-mount |
Flexible installation options |
| Protection Class |
IP20 (connector body); IP67 (M12 rugged variants) |
Dust-proof and rugged for field use |
| Connection Type |
M12, PG, AX, SC, SO144 (model-dependent) |
Standardized industrial interfaces |
| Conductor Range |
0.14~2.5mm² |
Compatible with common industrial cables |
| Signal Integrity |
EMI/RFI shielding |
Reduces electromagnetic interference |
| Certifications |
CE, UL, CSA |
Global industrial compliance |
| Mechanical Life |
≥1000 mating cycles |
Durable for frequent connection/disconnection |
Application Scenarios & Recommended Models
1. CAN Bus Rugged Field Connection
- Requirement: M12 rugged interface for CAN bus devices in harsh environments
- Recommended Models: 2902326 (CAN/AX/M12), 2902323 (90°/M12)
- Key Reason: M12 interface is dust/water-resistant; angled variants save space in tight cabinets
2. PROFIBUS Network Integration
- Requirement: Reliable PROFIBUS device connection for industrial automation
- Recommended Model: 2744348 (SUBCON-PLUS-PROFIB)
- Key Reason: PROFIBUS-optimized design ensures stable data transmission in industrial networks
3. Space-Constrained CAN Bus Installations
- Requirement: Low-profile angled connection for CAN bus in compact cabinets
- Recommended Models: 2902731 (90X/M12), 2902325 (35°/M12)
- Key Reason: Angled design avoids cable bending; M12 interface ensures ruggedness
4. ARCNET Industrial Network Connection
- Requirement: ARCNET bus device integration with AX/SC038 interface
- Recommended Model: 2903271 (SUBCON-PLUS-ARCNET/AX/SC038)
- Key Reason: Dedicated ARCNET compatibility; dual interface fits diverse device connections
5. Bus Line Shorting/Termination
- Requirement: Short or terminate bus lines for signal stability
- Recommended Model: 2799694 (SUBCON-SHORT-SCREW)
- Key Reason: Screw-type design for secure shorting/termination of bus lines
Core Advantages
- Multi-Bus Compatibility: Supports PROFIBUS/CAN/ARCNET, covering mainstream industrial bus needs
- Rugged Interfaces: M12/PG variants offer IP67 protection for field-installed devices
- Flexible Mounting: Angled (35°/90°) and straight options fit space-constrained installations
- Signal Stability: EMI/RFI shielding ensures interference-free communication in noisy environments
- Industrial-Grade Durability: Wide temperature range (-25℃~70℃) and robust construction resist harsh conditions
- Standardized Design: Complies with industrial interface standards for universal compatibility
- Easy Installation: Tool-free mating (some variants) and DIN rail/panel-mount options simplify deployment
Installation & Usage Notes
- Bus Protocol Matching: Select models based on the target bus protocol (e.g., CAN models for CAN bus systems)
- Interface Compatibility: Verify device interface (M12/PG/AX) matches the connector type
- Cable Selection: Use shielded industrial cables to maximize signal integrity and EMI protection
- Mounting Torque: Tighten M12/PG connectors to recommended torque (0.5~0.8Nm) for secure connections
- Cable Routing: Avoid routing bus cables near power lines to reduce cross-interference
- Termination: Use appropriate termination resistors (if required) for bus line signal stability
- Maintenance Checks: Regularly inspect connectors for damage or loose connections; clean contacts periodically