Phoenix TRIO Series: Industrial Power Supplies & Redundancy Modules - Selection Guide 

Product Overview

The Phoenix TRIO Series encompasses robust industrial power supplies, redundancy diodes, and battery backup modules designed for reliable power distribution and protection in automation systems. Covering IP67-rated waterproof power supplies (TRIO-PS-IP67/TRIO-PS67), redundancy diode modules (TRIO-DIODE/TRIO2-DIODE), and battery backup units (TRIO-BAT/PB), these products support 12V~48V DC output, 3.75A~20A current ratings, and both indoor (control cabinet) and outdoor (IP67) installations. Ideal for manufacturing, process automation, and harsh environment applications, they feature high efficiency, wide input voltage ranges, and compliance with global industrial standards—ensuring stable power for PLCs, sensors, actuators, and critical control equipment.

Model Quick Reference Table

1. TRIO-PS/PS67 IP67 Waterproof Power Supplies

Model No. Product Name Input Voltage Output Specification Key Features Application Scenarios
1039829 TRIO-PS-IP67/3AC/24DC/20 3-Phase AC 24V DC, 20A IP67 waterproof, high current Outdoor/harsh environment 3-phase AC to 24V DC power
1039830 TRIO-PS-IP67/1AC/24DC/20 Single-Phase AC 24V DC, 20A IP67 waterproof, 20A output Outdoor single-phase AC to 24V DC heavy-load power
1065976 TRIO-PS67/1AC/24DC/8/INC Single-Phase AC 24V DC, 8A INC increment function, IP67 Outdoor 8A power supply with scalable output
1278302 TRIO-PS67/1AC/24DC/3.75/INC Single-Phase AC 24V DC, 3.75A INC function, low current Outdoor low-power sensor/actuator power
1111634 TRIO-PS67/1AC/24DC/10/M12 Single-Phase AC 24V DC, 10A M12 connector, IP67 Outdoor M12-compatible device power (e.g., industrial cameras)
1111664 TRIO-PS67/1AC/24DC/10/IPD Single-Phase AC 24V DC, 10A IPD function, IP67 Outdoor intelligent power distribution

2. TRIO/TRIO2-DIODE Redundancy Modules

Model No. Product Name Input Voltage Range Output Configuration Key Features Application Scenarios
2866527 TRIO-DIODE/48DC/2X10/1X20 48V DC 2×10A + 1×20A Redundancy protection, high current 48V DC system dual-power redundancy (heavy loads)
2866514 TRIO-DIODE/12-24DC/2X10/1X20 12-24V DC 2×10A + 1×20A Wide input range, redundancy 12-24V DC system power redundancy (general loads)
2907379 TRIO2-DIODE/12-24DC/2X20/1X40 12-24V DC 2×20A + 1×40A High-current redundancy, TRIO2 series 12-24V DC large-scale system dual-power backup
2907380 TRIO2-DIODE/12-24DC/2X10/1X20 12-24V DC 2×10A + 1×20A Standard redundancy, TRIO2 series 12-24V DC medium-scale system power redundancy

3. TRIO-BAT/PB Battery Backup Module

Model No. Product Name Nominal Voltage Capacity Key Features Application Scenarios
1394727 TRIO-BAT/PB/24DC/12AH 24V DC 12AH PB configuration, maintenance-free 24V DC system long-term backup (e.g., PLCs, HMIs)

Core Technical Specifications (Universal)

Parameter Value Notes
Power Supplies (TRIO-PS/PS67)    
Protection Class IP67 Dust/waterproof for outdoor/harsh environments
Input Voltage Range Single-Phase AC: 85~264V; 3-Phase AC: 320~550V Wide adaptation to global power grids
Output Voltage 24V DC (±1%) Stable output for sensitive electronics
Efficiency ≥90% Energy-saving, low heat generation
Operating Temperature -25℃~70℃ Adapts to extreme industrial conditions
Mounting Type Wall-mount / DIN rail (model-dependent) Flexible installation options
Certifications CE, UL, CSA, IEC 61010-1 Global industrial compliance
Redundancy Diodes (TRIO/TRIO2-DIODE)    
Isolation Voltage 2kV (input-output) Anti-interference, protects control circuits
Response Time ≤1ms Fast redundancy switching (no power interruption)
Operating Temperature -25℃~70℃ Harsh environment compatibility
Mounting Type 35mm DIN rail (NS 35/7.5) Standard control cabinet installation
Protection Functions Overcurrent, overtemperature Comprehensive circuit protection
Battery Backup (TRIO-BAT/PB)    
Battery Type Sealed lead-acid (SLA) Maintenance-free, 2-5 year service life
Charging Temperature Range 0℃~40℃ Optimal charging conditions
Protection Class IP20 (cabinet mounting) Dust-proof for indoor use

Application Scenarios & Recommended Models

1. Outdoor/Harsh Environment Heavy-Load Power

  • Requirement: 24V DC 20A power for outdoor industrial equipment (3-phase AC input)
  • Recommended Model: 1039829 (TRIO-PS-IP67/3AC/24DC/20)
  • Key Reason: IP67 waterproof/dustproof; 3-phase input for stable high-current output

2. 12-24V DC Large-Scale System Redundancy

  • Requirement: Dual-power backup for 12-24V DC large-scale automation systems (40A max load)
  • Recommended Model: 2907379 (TRIO2-DIODE/12-24DC/2X20/1X40)
  • Key Reason: 40A maximum output; TRIO2 series high reliability for critical systems

3. Outdoor Low-Power Sensor Power

  • Requirement: 24V DC 3.75A power for outdoor sensors with scalable output
  • Recommended Model: 1278302 (TRIO-PS67/1AC/24DC/3.75/INC)
  • Key Reason: INC increment function for output scaling; IP67 protection for harsh conditions

4. 24V DC Long-Term Backup Power

  • Requirement: 24V DC backup for PLCs/HMIs during power outages (12AH capacity)
  • Recommended Model: 1394727 (TRIO-BAT/PB/24DC/12AH)
  • Key Reason: 12AH high capacity; maintenance-free SLA battery for long service life

5. 48V DC Heavy-Load Redundancy

  • Requirement: Dual-power redundancy for 48V DC industrial drives (20A max load)
  • Recommended Model: 2866527 (TRIO-DIODE/48DC/2X10/1X20)
  • Key Reason: 48V DC compatibility; 20A high-current output for heavy loads

Core Advantages

  • IP67 Waterproof Design: Power supplies suitable for outdoor/harsh environments (dust, water spray)
  • Dual Redundancy Series: TRIO/TRIO2-DIODE modules ensure uninterrupted power (no single-point failure)
  • Wide Voltage/Current Coverage: 3.75A~20A current, 12V~48V DC output fits diverse industrial needs
  • High Efficiency: Power supplies with ≥90% efficiency reduce energy consumption and heat
  • Industrial-Grade Reliability: -25℃~70℃ operating temperature, robust construction for harsh conditions
  • Flexible Installation: Wall-mount/DIN rail options for power supplies; DIN rail for redundancy modules
  • Global Compliance: CE/UL/CSA certifications enable international deployment

Installation & Usage Notes

  • Power Supply Installation: For IP67 models, ensure proper cable gland sealing to maintain waterproof rating; avoid submersion (IP67 = water-resistant, not waterproof)
  • Redundancy Wiring: Follow dual-power input wiring guidelines (separate cables for each power supply) to ensure redundancy functionality
  • Battery Backup Setup: Connect TRIO-BAT/PB to compatible TRIO power supplies; avoid overcharging (use dedicated charging circuits)
  • Voltage Matching: Ensure redundancy modules match system voltage (12-24DC/48DC) to prevent damage
  • Current Limitation: Do not exceed maximum output current of redundancy modules (e.g., 40A for TRIO2-DIODE/12-24DC/2X20/1X40)
  • Mounting Spacing: Reserve ≥5mm between redundancy modules for heat dissipation; install power supplies in well-ventilated areas
  • Maintenance Checks: Regularly inspect IP67 enclosures for damage; test redundancy switching periodically; check battery voltage for backup modules

Phoenix TRIO Series: Industrial Power Supplies & Redundancy Modules - Selection Guide

Created on:2025-11-25 11:27

News Dynamics

NEWS