Phoenix Contact PLC-OSC Series: Industrial Oscillators & Signal Conversion Modules - Selection Guide 

Product Overview

The Phoenix Contact PLC-OSC Series comprises industrial-grade oscillators and signal conversion modules designed for stable oscillating signal generation, voltage conversion, and interface integration in automation systems. Covering diverse input/output voltage combinations (DC/UC/AC), current ratings (1~500mA), frequency ranges (up to 100kHz), and functional variants (e.g., SEN, ACT, C1D2, G, RW, W), these modules deliver reliable signal processing, high isolation, and robust performance in harsh industrial environments. Ideal for PLC-based control systems, sensor/actuator interfaces, hazardous area applications, and high-frequency signal transmission, they feature 35mm DIN rail mounting, compact design, and global industrial compliance.

Model Quick Reference Table

1. High-Voltage Conversion Modules (Output: 300V DC)

Model No. Product Name Input Voltage Output Voltage Key Features Application Scenarios
2980665 PLC-OSC-12DC/300DC/1 12V DC 300V DC 1mA output 12V DC to 300V DC high-voltage signal generation
2980694 PLC-OSC-110DC/300DC/1 110V DC 300V DC 1mA output 110V DC industrial system to 300V DC equipment
2980681 PLC-OSC-60DC/300DC/1 60V DC 300V DC 1mA output 60V DC to 300V DC high-voltage signal conversion
2980652 PLC-OSC-5DC/300DC/1 5V DC 300V DC 1mA output 5V DC microcontroller to 300V DC high-voltage load

2. DC-DC Signal Conversion Modules (Standard Current: 100mA~500mA)

Model No. Product Name Input Voltage Output Voltage Key Features Application Scenarios
2980047 PLC-OSC-125DC/48DC/100 125V DC 48V DC 100mA output 125V DC to 48V DC industrial signal conversion
2966773 PLC-OSC-24DC/48DC/100/SEN 24V DC 48V DC 100mA, SEN sensor-dedicated 24V DC to 48V DC sensor power supply
2966728 PLC-OSC-24DC/48DC/100 24V DC 48V DC 100mA output 24V DC to 48V DC general signal conversion
2980636 PLC-OSC-24DC/48DC/500/W 24V DC 48V DC 500mA, W suffix High-current 24V DC to 48V DC conversion
5603261 PLC-OSC-24DC/48DC/100/C1D2 24V DC 48V DC 100mA, C1D2 hazardous area Hazardous location (Class I Div 2) signal conversion
2902966 PLC-OSC-24DC/5DC/100KHZ-G 24V DC 5V DC 100kHz, G enhanced anti-interference High-frequency 24V DC to 5V DC signal transmission
2902965 PLC-OSC-5DC/5DC/100KHZ-G 5V DC 5V DC 100kHz, G enhanced High-frequency 5V DC signal stabilization
2902967 PLC-OSC-5DC/24DC/100KHZ-G 5V DC 24V DC 100kHz, G enhanced High-frequency 5V DC to 24V DC conversion
2902963 PLC-OSC-5DC/24DC/100KHZ 5V DC 24V DC 100kHz frequency High-frequency 5V DC to 24V DC signal transmission

3. DC-AC Signal Conversion Modules (ACT Function)

Model No. Product Name Input Voltage Output Voltage Key Features Application Scenarios
2904631 PLC-OSC-24DC/230AC/2.4/ACT 24V DC 230V AC 2.4mA, ACT activation 24V DC to 230V AC actuator control
2967947 PLC-OSC-24DC/230AC/1/ACT 24V DC 230V AC 1mA, ACT activation 24V DC to 230V AC low-current actuation
2967840 PLC-OSC-24DC/230AC/1 24V DC 230V AC 1mA output 24V DC to 230V AC general signal conversion
2982760 PLC-OSC-24DC/230AC/2/ACT 24V DC 230V AC 2mA, ACT activation 24V DC to 230V AC medium-current actuation

4. Universal Input (UC) Modules

Model No. Product Name Input Voltage Output Voltage Key Features Application Scenarios
2966650 PLC-OSC-120UC/24DC/2 120V AC/DC (UC) 24V DC 2mA output Universal 120V AC/DC to 24V DC control signal
2966799 PLC-OSC-120UC/48DC/100/SEN 120V AC/DC (UC) 48V DC 100mA, SEN sensor-dedicated Universal 120V AC/DC to 48V DC sensor power
2966744 PLC-OSC-120UC/48DC/100 120V AC/DC (UC) 48V DC 100mA output Universal 120V AC/DC to 48V DC signal conversion
5603262 PLC-OSC-120UC/24DC/2/C1D2 120V AC/DC (UC) 24V DC 2mA, C1D2 hazardous area Hazardous location universal voltage signal conversion

5. Special Function Modules (High-Frequency/RW/C1D2)

Model No. Product Name Input Voltage Output Voltage Key Features Application Scenarios
2902968 PLC-OSC-24DC/24DC/100KHZ-G 24V DC 24V DC 100kHz, G enhanced High-frequency 24V DC signal transmission (anti-interference)
2902964 PLC-OSC-24DC/24DC/100KHZ 24V DC 24V DC 100kHz frequency High-frequency 24V DC signal generation
2980610 PLC-OSC-24DC/24DC/3RW 24V DC 24V DC 3mA, RW rail application Railway system 24V DC signal conversion
2980623 PLC-OSC-110DC/24DC/3RW 110V DC 24V DC 3mA, RW rail application Railway 110V DC to 24V DC signal conversion
2982702 PLC-OSC-24DC/24DC/10/R 24V DC 24V DC 10mA, R reverse protection 24V DC signal with reverse polarity protection
2982786 PLC-OSC-24DC/24DC/5/ACT 24V DC 24V DC 5mA, ACT activation 24V DC to 24V DC actuator control

Core Technical Specifications (Universal)

Parameter Value Notes
Input Voltage Range DC: 5V~125V; UC: 96V~144V AC/DC; AC: 198V~264V Model-dependent universal/compact ranges
Output Voltage 5V DC~300V DC, 230V AC Signal/voltage conversion flexibility
Output Current 1mA~500mA Low-to-medium current for signal/control applications
Frequency Range Up to 100kHz (high-frequency models) For high-speed signal transmission
Operating Temperature -25℃~70℃ (standard); -20℃~60℃ (high-frequency) Adapts to harsh industrial environments
Mounting Type 35mm DIN rail (NS 35/7.5) Compact design for space-saving cabinet layout
Protection Class IP20 (cabinet mounting) Dust-proof for industrial control cabinets
Protection Functions Reverse polarity (R-suffix), overvoltage, short-circuit Comprehensive equipment protection
Isolation Voltage 2.5kV (input-output) Prevents interference between control and load circuits
Certifications CE, UL, CSA; C1D2 (hazardous area models) Global industrial and hazardous location compliance
Response Time Standard: ≤40ms; High-frequency: ≤1.5μs Fast signal generation/adaptation

Application Scenarios & Recommended Models

1. Hazardous Area Signal Conversion (Class I Div 2)

  • Requirement: 24V DC to 48V DC 100mA signal for hazardous locations
  • Recommended Model: 5603261 (PLC-OSC-24DC/48DC/100/C1D2)
  • Key Reason: C1D2 certification ensures safe operation; 100mA output for sensor/actuator power

2. High-Frequency Signal Transmission (100kHz)

  • Requirement: 5V DC to 24V DC high-frequency signal (anti-interference)
  • Recommended Model: 2902967 (PLC-OSC-5DC/24DC/100KHZ-G)
  • Key Reason: 100kHz frequency; G suffix for enhanced anti-interference in noisy environments

3. Railway System Signal Conversion (RW)

  • Requirement: 110V DC to 24V DC signal for railway applications
  • Recommended Model: 2980623 (PLC-OSC-110DC/24DC/3RW)
  • Key Reason: RW suffix optimized for railway systems; 3mA stable output

4. Universal Voltage Signal Conversion (120V AC/DC)

  • Requirement: 120V AC/DC (universal) to 48V DC sensor power
  • Recommended Model: 2966799 (PLC-OSC-120UC/48DC/100/SEN)
  • Key Reason: UC universal input (global power grid compatibility); SEN sensor-dedicated design

5. DC-to-AC Actuator Control (ACT)

  • Requirement: 24V DC to 230V AC 2mA actuator control
  • Recommended Model: 2982760 (PLC-OSC-24DC/230AC/2/ACT)
  • Key Reason: ACT activation function; 2mA output for medium-current actuators

6. High-Voltage Signal Generation (300V DC)

  • Requirement: 5V DC/12V DC/60V DC/110V DC to 300V DC high-voltage signal
  • Recommended Models: 2980652 (5DC), 2980665 (12DC), 2980681 (60DC), 2980694 (110DC)
  • Key Reason: 1mA precision output for industrial test/control equipment

Core Advantages

  • Wide Voltage Compatibility: Covers 5V DC~125V DC input, 5V DC~300V DC/230V AC output for diverse industrial systems
  • Functional Diversification: Hazardous area (C1D2), sensor-dedicated (SEN), actuator control (ACT), high-frequency (100kHz), reverse protection (R), railway (RW) variants
  • High Precision & Stability: Up to 100kHz frequency range; ≤1.5μs response time for high-speed applications
  • Industrial-Grade Reliability: -25℃~70℃ operating temperature, 2.5kV isolation, and IP20 protection
  • Seamless Integration: DIN rail mounting, standard interfaces, and compatibility with PLCs/sensors/actuators
  • Global Compliance: CE/UL/CSA certifications; C1D2 rating for hazardous location deployment
  • Flexible Current Options: 1mA~500mA output current covers low-power signals to high-current sensor/actuator drives

Installation & Usage Notes

  • Voltage Matching: Ensure input/output voltage aligns with equipment requirements (e.g., UC models for mixed AC/DC input)
  • Hazardous Area Installation: C1D2 models must comply with Class I Div 2 wiring guidelines (proper grounding, approved cables)
  • High-Frequency Wiring: For 100kHz models, use shielded twisted-pair cables to minimize signal interference
  • Railway Application: RW-suffix models must meet railway system voltage fluctuations (110V DC ±20%)
  • Current Limitation: Do not exceed maximum output current (e.g., 500mA for 24DC/48DC/500/W)
  • ACT Function Setup: For ACT-suffixed models, connect activation signal lines to PLC digital outputs
  • Environmental Protection: Install in dry, dust-free control cabinets (IP20 protection); avoid direct exposure to moisture or corrosive substances
  • Calibration: For high-frequency/precision applications, verify signal stability post-installation (±0.1% frequency tolerance)

Phoenix Contact PLC-OSC Series: Industrial Oscillators & Signal Conversion Modules - Selection Guide

Created on:2025-11-25 11:39

News Dynamics

NEWS