The Phoenix MINI MCR-2 Series consists of ultra-compact, dual-channel signal conditioning, communication, and interface modules designed for space-constrained industrial automation systems. Covering core functional categories—including network communication (PROFINET/PROFIBUS/TCP/RTU), temperature measurement (RTD), power supply (RPS/RPSS), potentiometer signal conversion (POT), and specialized interfaces (V8/PTB/FLK 16)—these modules support dual-channel signal processing, diverse industrial protocols, and global compliance. Featuring a 6.2mm narrow design, 35mm DIN rail mounting, and options for plug-in terminals (PT) or fixed wiring, they excel in sensor signal conditioning, PLC network integration, and critical parameter monitoring in control cabinets, compact machinery, and process automation.
Model Quick Reference Table
1. Network Communication Modules (V8 Series)
| Model No. | Product Name | Key Features | Application Scenarios |
|---|---|---|---|
| 2905637 | MINI MCR-2-V8-PN | PROFINET communication, dual-channel | PROFINET network integration for industrial devices |
| 2905636 | MINI MCR-2-V8-PB-DP | PROFIBUS DP communication, dual-channel | PROFIBUS DP network connectivity for automation systems |
| 2905635 | MINI MCR-2-V8-MOD-TCP | Modbus TCP communication, dual-channel | Modbus TCP network integration for smart devices |
| 2905634 | MINI MCR-2-V8-MOD-RTU | Modbus RTU communication, dual-channel | Modbus RTU serial communication for remote devices |
| 2901993 | MINI MCR-2-V8-FLK 16 | FLK 16 interface, dual-channel | Specialized FLK 16 protocol communication |
2. Power Supply Modules (SPS/RPS/RPSS Series)
| Model No. | Product Name | Key Features | Application Scenarios |
|---|---|---|---|
| 1033201 | MINI MCR-2-SPS-24-15-PT | 24V DC→15V DC power supply, PT plug-in terminal | Compact 15V DC sensor/module power (tool-free wiring) |
| 1033202 | MINI MCR-2-SPS-24-15 | 24V DC→15V DC power supply, fixed terminal | Standard 15V DC low-power power distribution |
| 2902015 | MINI MCR-2-RPSS-I-I-PT | Dual-channel current isolation, PT terminal | Noise-free dual-channel current signal transmission |
| 2902014 | MINI MCR-2-RPSS-I-I | Dual-channel current isolation, fixed terminal | Standard dual-channel current signal isolation |
| 2905629 | MINI MCR-2-RPSS-I-2I-PT | 1-channel in→2-channel out current distribution, PT terminal | Dual-output current signal splitting (tool-free wiring) |
| 2905628 | MINI MCR-2-RPSS-I-2I | 1-channel in→2-channel out current distribution, fixed terminal | Standard current signal splitting for dual PLC inputs |
| 2906447 | MINI MCR-2-RPS-I-I-OLP-PT | Dual-channel current isolation + OLP function, PT terminal | Isolated current signal processing with OLP protection |
| 2906446 | MINI MCR-2-RPS-I-I-OLP | Dual-channel current isolation + OLP function, fixed terminal | Standard isolated signal processing with OLP protection |
| 2906449 | MINI MCR-2-RPS-2I-2I-OLP-PT | 2-channel in→2-channel out isolation + OLP, PT terminal | High-density dual-in/dual-out current isolation |
| 2906448 | MINI MCR-2-RPS-2I-2I-OLP | 2-channel in→2-channel out isolation + OLP, fixed terminal | Standard high-density current isolation |
3. Temperature Measurement Modules (RTD Series)
| Model No. | Product Name | Key Features | Application Scenarios |
|---|---|---|---|
| 2902052 | MINI MCR-2-RTD-UI-PT | RTD sensor input→voltage/current output, PT terminal | RTD temperature signal conditioning (tool-free wiring) |
| 2902048 | MINI MCR-2-RTD-UI-C | RTD sensor input→voltage/current output, C-suffix | Customized RTD temperature signal conversion |
| 2902049 | MINI MCR-2-RTD-UI | RTD sensor input→voltage/current output, fixed terminal | Standard RTD temperature signal conditioning |
4. Specialized Interface Modules (POT/PTB Series)
| Model No. | Product Name | Key Features | Application Scenarios |
|---|---|---|---|
| 2902017 | MINI MCR-2-POT-UI-PT | Potentiometer (POT) signal→voltage/current, PT terminal | Potentiometer-based control signal conversion (tool-free) |
| 2902016 | MINI MCR-2-POT-UI | Potentiometer (POT) signal→voltage/current, fixed terminal | Standard potentiometer signal conditioning |
| 2902067 | MINI MCR-2-PTB-PT | PTB certification, dual-channel, PT terminal | PTB-compliant signal processing (tool-free wiring) |
| 2902066 | MINI MCR-2-PTB | PTB certification, dual-channel, fixed terminal | Standard PTB-compliant industrial signal processing |
Core Technical Specifications (Universal)
| Parameter | Value | Notes |
|---|---|---|
| Module Width | 6.2mm (dual-channel) | Ultra-compact for dense cabinet layouts (up to 32 modules/meter) |
| Supply Voltage | 24V DC (19.2~28.8V) | Industrial standard power supply |
| Input/Output Types | Current (4-20mA), Voltage (0-10V), RTD (PT100/PT1000), Potentiometer | Model-dependent signal compatibility |
| Communication Protocols | PROFINET (PN), PROFIBUS DP (PB-DP), Modbus TCP/RTU | Network modules only |
| Terminal Types | PT (plug-in): Tool-free, 0.14~2.5mm²; Fixed: Screw terminals, 0.14~2.5mm² | PT for fast maintenance; fixed for secure wiring |
| Isolation Voltage | 3kV (input-output-supply) | Anti-interference, protects control systems |
| Operating Temperature | -25℃~70℃ | Adapts to harsh industrial environments |
| Mounting Type | 35mm DIN rail (NS 35/7.5) | Snap-fit installation, no tools required |
| Conversion Accuracy | ≤±0.1% FS | High-precision signal processing |
| Certifications | CE, UL, CSA, PTB (PTB-suffix models) | Global industrial compliance |
Application Scenarios & Recommended Models
1. PROFINET Network Integration (Dual-Channel)
- Requirement: Dual-channel PROFINET communication for industrial sensors/devices
- Recommended Model: 2905637 (MINI MCR-2-V8-PN)
- Key Reason: PROFINET protocol compliance; dual-channel design saves cabinet space
2. RTD Temperature Signal Conditioning (Tool-Free Wiring)
- Requirement: RTD sensor temperature→voltage/current conversion with quick maintenance
- Recommended Model: 2902052 (MINI MCR-2-RTD-UI-PT)
- Key Reason: PT plug-in terminal for fast wiring; high-precision RTD signal processing
3. Current Signal Isolation & Distribution (Dual-Output)
- Requirement: 1-channel current input→2-channel isolated output for dual PLCs
- Recommended Model: 2905629 (MINI MCR-2-RPSS-I-2I-PT)
- Key Reason: Dual-output distribution; 3kV isolation; PT terminal for easy installation
4. Potentiometer Control Signal Conversion
- Requirement: Potentiometer analog signal→standard voltage/current for PLC input
- Recommended Model: 2902017 (MINI MCR-2-POT-UI-PT)
- Key Reason: Potentiometer-specific design; PT plug-in terminal for tool-free wiring
5. Compact Power Supply (24V DC→15V DC)
- Requirement: Space-saving 15V DC power for small sensors/modules
- Recommended Model: 1033201 (MINI MCR-2-SPS-24-15-PT)
- Key Reason: 6.2mm ultra-narrow design; PT terminal for fast deployment
Core Advantages
- Ultra-Compact Dual-Channel Design: 6.2mm width maximizes dense cabinet utilization (dual-channel functionality reduces module count)
- Multi-Protocol Network Support: PROFINET/PROFIBUS/Modbus TCP/RTU covers mainstream industrial networks
- Flexible Terminal Options: PT (plug-in) for fast maintenance; fixed screw terminals for vibration-prone environments
- Diverse Functional Coverage: Temperature measurement, power supply, signal isolation, and network communication in one series
- Industrial-Grade Reliability: 3kV isolation, -25℃~70℃ operating temperature, and ±0.1% conversion accuracy
- Easy Integration: DIN rail mounting and standardized interfaces simplify PLC/sensor connectivity
- Global Compliance: CE/UL/CSA/PTB certifications enable international deployment
Installation & Usage Notes
- Protocol Matching: Select network modules based on target protocol (PN/PB-DP/Modbus TCP/RTU)
- Terminal Selection: Choose PT plug-in terminals for frequent maintenance; fixed terminals for harsh/vibration environments
- RTD Wiring: For RTD models, verify sensor type (PT100/PT1000) and wiring configuration (2/3/4-wire)
- Power Supply: Ensure 24V DC (19.2~28.8V) input to avoid module damage; use decoupling capacitors for noisy power lines
- Mounting Spacing: Reserve ≥3mm between modules for heat dissipation, especially in dense layouts
- Calibration: For precision applications (temperature/potentiometer), verify accuracy post-installation (±0.1% FS tolerance)
- Environmental Protection: Install in dry, dust-free control cabinets (IP20 protection); avoid direct moisture or corrosive exposure