Phoenix IB IL Series: Industrial Signal Input & System Modules - Selection Guide 

Product Overview

The Phoenix IB IL Series encompasses specialized industrial modules for signal input, system communication, and temperature measurement, designed exclusively for IB bus distributed automation systems. Covering core functional categories—temperature measurement (RTD/NTC)SSI absolute encoder interfacesSGI sensor signal modules, and SCN system communication/power modules—these devices support diverse industrial signals (RTD/SSI/sensor inputs) and feature flexible packaging (PAC plug-and-play, standard mounting) with 35mm DIN rail compatibility. Ideal for manufacturing automation, process control, and industrial monitoring, they ensure reliable signal acquisition, system integration, and power distribution in harsh industrial environments.

Model Quick Reference Table

1. Temperature Measurement Modules (RTD/NTC-ECO Series)

Model No. Product Name Key Features Application Scenarios
2702499 IB IL RTD 4/PT100-ECO 4-channel, PT100 sensor input, ECO variant 4-channel PT100 temperature measurement (cost-effective)
2702501 IB IL RTD 4/PT1000-ECO 4-channel, PT1000 sensor input, ECO variant 4-channel PT1000 temperature signal acquisition
1185434 IB IL RTD 4/NTC-ECO 4-channel, NTC sensor input, ECO variant 4-channel NTC temperature monitoring for industrial systems
2702504 IB IL UTH 4/L-ECO 4-channel, UTH L-type temperature sensor input 4-channel specialized temperature measurement (L-type sensor)
2702503 IB IL UTH 4/K-ECO 4-channel, UTH K-type temperature sensor input 4-channel specialized temperature measurement (K-type sensor)
2702502 IB IL UTH 4/J-ECO 4-channel, UTH J-type temperature sensor input 4-channel specialized temperature measurement (J-type sensor)

2. SSI Encoder Interface Modules

Model No. Product Name Key Features Application Scenarios
2861865 IB IL SSI-PAC SSI absolute encoder interface, PAC plug-and-play Quick connection for SSI absolute encoders (tool-free deployment)
2819574 IB IL SSI-IN-PAC SSI input interface, PAC packaging SSI encoder signal input (plug-and-play installation)
2819309 IB IL SSI-IN SSI input interface, standard mounting Standard SSI encoder signal acquisition (fixed installation)

3. SGI Sensor Signal Modules

Model No. Product Name Key Features Application Scenarios
2702373 IB IL SGI 2/P/EF-PAC 2-channel sensor interface, P-type, EF enhanced function, PAC Enhanced 2-channel sensor signal processing (plug-and-play)
2878638 IB IL SGI 2/F-PAC 2-channel sensor interface, F-type, PAC packaging 2-channel sensor signal acquisition (plug-and-play)

4. SCN System Communication & Power Modules

Model No. Product Name Key Features Application Scenarios
2860691 IB IL SCN-PWR IN-CP/UN Power input module, CP configuration, universal voltage Universal voltage system power input for IB bus networks
2727637 IB IL SCN-PWR IN-CP Power input module, CP configuration Standard IB bus system power supply
2727608 IB IL SCN-8-CP 8-channel system communication module, CP configuration 8-channel IB bus communication expansion
2726337 IB IL SCN-8 8-channel system communication module Standard 8-channel IB bus communication
2740711 IB IL SCN-6 SHIELD/N 6-channel communication module, shielded, N-suffix 6-channel shielded IB bus communication (noise suppression)
2726353 IB IL SCN-6 SHIELD 6-channel communication module, shielded 6-channel shielded IB bus signal transmission
2740245 IB IL SCN 6-SHIELD-TWIN 6-channel twin shielded communication module Twin 6-channel shielded IB bus communication (high density)
2740494 IB IL SCN-12-OCP/N 12-channel communication module, OCP function, N-suffix 12-channel IB bus communication with OCP protection
2727624 IB IL SCN-12-OCP 12-channel communication module, OCP function 12-channel IB bus communication with overcurrent protection
2740481 IB IL SCN-12-ICP/N 12-channel communication module, ICP function, N-suffix 12-channel IB bus communication with ICP protection
2727611 IB IL SCN-12-ICP 12-channel communication module, ICP function 12-channel IB bus communication with current protection
2726340 IB IL SCN-12 12-channel system communication module Standard 12-channel IB bus communication expansion

Core Technical Specifications (Universal)

Parameter Value Notes
Bus Protocol IB Bus Dedicated to IB bus distributed automation systems
Supply Voltage 24V DC (19.2~28.8V) Industrial standard power supply
Channel Count 4-channel (temperature); 2/6/8/12-channel (communication/sensor) Model-dependent signal coverage
Input Sensor Types RTD (PT100/PT1000), NTC, UTH (L/K/J-type), SSI encoder, industrial sensors Temperature/sensor modules only
Operating Temperature -25℃~70℃ Adapts to harsh industrial environments
Mounting Type 35mm DIN rail (NS 35/7.5) Snap-fit installation for quick deployment
Packaging Type PAC (Plug-and-Play): Pre-wired connectors; Standard: Screw terminals PAC for fast maintenance; standard for fixed setups
Protection Class IP20 (cabinet mounting) Dust-proof for industrial control cabinets
Isolation Voltage 2kV (input-output-supply) Anti-interference for stable signal transmission
Certifications CE, UL, CSA Global industrial compliance
Conversion Accuracy ≤±0.1% FS (temperature modules) High-precision temperature measurement

Application Scenarios & Recommended Models

1. Multi-Channel PT100 Temperature Measurement

  • Requirement: 4-channel PT100 temperature monitoring for industrial process control
  • Recommended Model: 2702499 (IB IL RTD 4/PT100-ECO)
  • Key Reason: ECO cost-effective variant; 4-channel density; high-precision PT100 compatibility

2. SSI Absolute Encoder Integration (Quick Deployment)

  • Requirement: Plug-and-play SSI encoder signal input for motion control systems
  • Recommended Model: 2861865 (IB IL SSI-PAC)
  • Key Reason: PAC plug-and-play packaging; seamless SSI encoder interface; fast wiring

3. Noise-Suppressed IB Bus Communication (6-Channel)

  • Requirement: 6-channel shielded IB bus communication for noisy industrial environments
  • Recommended Model: 2726353 (IB IL SCN-6 SHIELD)
  • Key Reason: Shielded design reduces EMI interference; 6-channel expansion for distributed systems

4. Specialized UTH Temperature Measurement (K-Type)

  • Requirement: 4-channel K-type UTH sensor temperature acquisition
  • Recommended Model: 2702503 (IB IL UTH 4/K-ECO)
  • Key Reason: K-type UTH sensor compatibility; ECO variant for cost-sensitive applications

5. 12-Channel IB Bus Communication with Overcurrent Protection

  • Requirement: 12-channel IB bus expansion with overcurrent protection (OCP)
  • Recommended Model: 2727624 (IB IL SCN-12-OCP)
  • Key Reason: 12-channel high density; OCP function safeguards system from current spikes

Core Advantages

  • IB Bus Specialization: Seamless compatibility with IB bus distributed automation systems
  • Diverse Functional Coverage: Temperature measurement, encoder interface, sensor signal processing, and system communication
  • Flexible Packaging Options: PAC plug-and-play for fast maintenance; standard mounting for fixed installations
  • Industrial-Grade Reliability: -25℃~70℃ operating temperature, 2kV isolation, and IP20 protection
  • High-Precision Measurement: ≤±0.1% FS accuracy for temperature modules ensures reliable process monitoring
  • Space-Saving Design: Compact DIN rail mounting optimizes control cabinet utilization
  • Global Compliance: CE/UL/CSA certifications enable international deployment

Installation & Usage Notes

  • Bus Compatibility: Ensure modules match the target IB bus system version (verify firmware for integration)
  • Sensor Matching: For temperature modules, confirm sensor type (PT100/PT1000/NTC/UTH) matches module specifications
  • Packaging Selection: Use PAC modules for systems requiring frequent maintenance; standard modules for vibration-prone environments
  • Wiring Specifications: For standard screw terminals, use 0.14~2.5mm² conductors; strip wires to 7mm and tighten to 0.5~0.6Nm
  • Shielded Communication: For SCN SHIELD models, properly ground shielded cables to maximize noise suppression
  • Mounting Spacing: Reserve ≥5mm between modules for heat dissipation, especially for high-channel-count variants
  • Environmental Protection: Install in dry, dust-free control cabinets (IP20 protection); avoid direct moisture or corrosive exposure

Phoenix IB IL Series: Industrial Signal Input & System Modules - Selection Guide

Created on:2025-11-25 11:46

News Dynamics

NEWS