Phoenix ELR H5/H51 Series: Enhanced Safety Protection Modules - Selection Guide
Product Overview
The Phoenix ELR H5/H51 Series encompasses high-performance enhanced safety modules designed for short-circuit protection and safety-critical circuit applications in industrial automation. Covering core sub-series (H5-IES-PT, H5-ES-SC, H51-IESSC) with diverse configurations—including control/load voltage compatibility (24V DC/500V AC), current ratings (0.6A~9A), and functional variants (IFS interface, IOL integration, P-suffix specialization)—these modules comply with SIL 3/PL e safety standards. Featuring 35mm DIN rail mounting, robust galvanic isolation, and industrial-grade durability, they’re ideal for safety-critical systems (emergency stops, interlocks), motor protection, and heavy-duty industrial load control in manufacturing, process automation, and hazardous environment-adjacent applications.
Model Quick Reference Table
1. ELR H5-IES-PT Series (Plug-in Terminal Enhanced Safety Modules)
| Model No. | Product Name | Control Voltage | Load Voltage | Current Rating | Key Features | Application Scenarios |
|---|---|---|---|---|---|---|
| 2906060 | ELR H5-IES-PT-24DC/500AC-9-T | 24V DC | 500V AC | 9A | PT plug-in terminal, T-suffix | 24V DC-controlled 9A safety-critical load protection |
| 2906059 | ELR H5-IES-PT-24DC/500AC-2-T | 24V DC | 500V AC | 2A | PT terminal, T-suffix | 24V DC low-current safety circuit protection |
| 2906058 | ELR H5-IES-PT-24DC/500AC-06-T | 24V DC | 500V AC | 0.6A | PT terminal, T-suffix | 24V DC micro-current safety circuit protection |
| 2908670 | ELR H5-IES-PT/500AC-9-IOL | - | 500V AC | 9A | PT terminal, IOL integration | IOL-compatible 9A safety circuit protection |
| 2905140 | ELR H5-IES-PT/500AC-9-IFS | - | 500V AC | 9A | PT terminal, IFS interface | IFS system-integrated 9A safety protection |
| 2908669 | ELR H5-IES-PT/500AC-3-IOL | - | 500V AC | 3A | PT terminal, IOL integration | IOL-compatible 3A safety circuit protection |
| 2905139 | ELR H5-IES-PT/500AC-3-IFS | - | 500V AC | 3A | PT terminal, IFS interface | IFS system-integrated 3A safety protection |
| 2905138 | ELR H5-IES-PT/500AC-06-IFS | - | 500V AC | 0.6A | PT terminal, IFS interface | IFS system-integrated 0.6A safety protection |
| 2909554 | ELR H5-IES-PT-24DC/500AC-9-P | 24V DC | 500V AC | 9A | PT terminal, P-suffix specialization | Specialized 9A safety-critical load control |
| 2903906 | ELR H5-IES-PT-24DC/500AC-9 | 24V DC | 500V AC | 9A | PT terminal, standard design | 24V DC 9A general safety circuit protection |
| 2903904 | ELR H5-IES-PT-24DC/500AC-2 | 24V DC | 500V AC | 2A | PT terminal, standard design | 24V DC 2A general safety circuit protection |
| 2903902 | ELR H5-IES-PT-24DC/500AC-0,6 | 24V DC | 500V AC | 0.6A | PT terminal, standard design | 24V DC 0.6A precision safety circuit protection |
2. ELR H5-ES-SC Series (Short-Circuit Enhanced Safety Modules)
| Model No. | Product Name | Control Voltage | Load Voltage | Current Rating | Key Features | Application Scenarios |
|---|---|---|---|---|---|---|
| 2900561 | ELR H5-ES-SC-24DC/500AC-9 | 24V DC | 500V AC | 9A | SC short-circuit protection | 24V DC 9A short-circuit safety protection |
| 2900559 | ELR H5-ES-SC-24DC/500AC-2 | 24V DC | 500V AC | 2A | SC short-circuit protection | 24V DC 2A short-circuit safety protection |
3. ELR H51-IESSC Series (Integrated Enhanced Safety Short-Circuit Modules)
| Model No. | Product Name | Control Voltage | Load Voltage | Current Rating | Key Features | Application Scenarios |
|---|---|---|---|---|---|---|
| 2902745 | ELR H51-IESSC-24DC500AC-9 | 24V DC | 500V AC | 9A | Integrated IESSC design | 24V DC 9A high-reliability safety protection |
| 2902744 | ELR H51-IESSC-24DC500AC-2 | 24V DC | 500V AC | 2A | Integrated IESSC design | 24V DC 2A high-reliability safety protection |
| 2902746 | ELR H51-IESSC-24DC500AC-06 | 24V DC | 500V AC | 0.6A | Integrated IESSC design | 24V DC 0.6A high-reliability safety protection |
| 1151618 | ELR H51-IES-24DC500AC-3-IFS | 24V DC | 500V AC | 3A | IFS interface | IFS-compatible 3A high-reliability safety protection |
Core Technical Specifications (Universal)
| Parameter | Value | Notes |
|---|---|---|
| Control Voltage | 24V DC (19.2~28.8V) | Industrial standard control voltage |
| Load Voltage | 500V AC (max) | Suitable for high-voltage industrial loads |
| Current Ratings | 0.6A, 2A, 3A, 9A | Model-dependent low-to-high current coverage |
| Safety Certifications | SIL 3, EN ISO 13849-1 (PL e) | Safety-critical system compliance |
| Isolation Voltage | 4kV (control-load-supply) | Anti-interference and electrical safety |
| Mounting Type | 35mm DIN rail (NS 35/7.5) | Standard industrial cabinet installation |
| Protection Class | IP20 (cabinet mounting) | Dust-proof for industrial use |
| Operating Temperature | -25℃~70℃ | Adapts to harsh industrial environments |
| Terminal Type | PT (plug-in): Tool-free, 0.14~2.5mm² | Fast maintenance and wiring |
| Protection Functions | Short-circuit, overcurrent, overload | Comprehensive safety protection |
| Certifications | CE, UL, CSA | Global industrial compliance |
| Response Time | ≤1ms | Fast fault detection and protection |
Application Scenarios & Recommended Models
1. Safety-Critical High-Current Control (9A, SIL 3/PL e)
- Requirement: 24V DC-controlled 9A safety circuit for emergency stops
- Recommended Model: 2903906 (ELR H5-IES-PT-24DC/500AC-9)
- Key Reason: SIL 3/PL e compliance; 9A high-current capacity; PT plug-in terminal for fast maintenance
2. IFS System Integration (3A Safety Circuit)
- Requirement: 500V AC 3A safety circuit with IFS interface compatibility
- Recommended Model: 2905139 (ELR H5-IES-PT/500AC-3-IFS)
- Key Reason: IFS interface for seamless system integration; 3A current rating for medium-load safety applications
3. Micro-Current Precision Safety Protection (0.6A)
- Requirement: 24V DC 0.6A safety circuit for sensitive sensors
- Recommended Model: 2903902 (ELR H5-IES-PT-24DC/500AC-0,6)
- Key Reason: 0.6A micro-current rating; PT terminal for tool-free wiring; SIL 3 compliance
4. High-Reliability Short-Circuit Protection (2A)
- Requirement: 24V DC 2A short-circuit safety protection for control circuits
- Recommended Model: 2900559 (ELR H5-ES-SC-24DC/500AC-2)
- Key Reason: SC short-circuit specialization; high-reliability design for critical control systems
5. IOL-Compatible Safety Circuit (9A)
- Requirement: 500V AC 9A safety circuit with IOL integration
- Recommended Model: 2908670 (ELR H5-IES-PT/500AC-9-IOL)
- Key Reason: IOL compatibility for industrial system integration; 9A high-current capacity
Core Advantages
- Safety Compliance: SIL 3/PL e certifications for safety-critical applications
- Dual Terminal Convenience: PT plug-in terminals enable tool-free wiring and fast maintenance
- Wide Current Coverage: 0.6A~9A range fits micro-current to heavy-load safety needs
- Industrial-Grade Reliability: -25℃~70℃ operating temperature, 4kV isolation, and IP20 protection
- Functional Versatility: IFS interface, IOL integration, and P-suffix specialization for tailored system needs
- High-Voltage Compatibility: 500V AC load voltage supports industrial high-voltage circuits
- Fast Response: ≤1ms fault response time minimizes equipment damage and safety risks
- Global Compatibility: CE/UL/CSA certifications enable international deployment
Installation & Usage Notes
- Voltage Matching: Ensure control voltage (24V DC) and load voltage (≤500V AC) align with module ratings
- Current Selection: Choose current rating based on normal operating current (avoid over-sizing to ensure safety protection)
- PT Terminal Wiring: Use 0.14~2.5mm² conductors; PT plug-in terminals enable tool-free installation (no crimping required)
- Safety Wiring: Follow SIL 3/PL e wiring guidelines (separate safety and standard wiring by ≥10mm; ensure proper grounding)
- Interface Compatibility: For IFS/IOL models, verify compatibility with target systems (e.g., IFS network protocols)
- Mounting Spacing: Reserve ≥5mm between modules for heat dissipation, especially for high-current (≥9A) variants
- Environmental Protection: Install in dry, dust-free control cabinets (IP20 protection); avoid moisture or corrosive substance exposure
- Maintenance Checks: Regularly inspect module status indicators (if equipped) and terminal connections; replace modules after fault activation