Phoenix AXL F Series: Bus Couplers & Analog I/O Modules - Selection Guide 

Product Overview

The Phoenix AXL F Series includes high-performance bus couplers (BK) and analog I/O modules designed for modular automation systems. The bus couplers support diverse industrial networks (PROFINET, PROFIBUS, Ethernet, EtherNet/IP) with extended temperature (XC) and enhanced functionality (EF/TPS) variants, enabling seamless integration of AXL F modules into global industrial networks. The analog I/O modules cover 2/4/8-channel configurations for analog input (AI) and output (AO), including HART communication support, extended temperature ratings, and universal/current-specific input options. Featuring 35mm DIN rail mounting, compact design, and industrial-grade reliability, these modules are ideal for process control, precision measurement, and distributed automation systems in manufacturing and process industries.

Model Quick Reference Table

1. AXL F BK (Bus Couplers)

Model No. Product Name Key Features Application Scenarios
2701457 AXL F BK SAS SAS interface bus coupler Specialized SAS network integration for AXL F modules
2701686 AXL F BK S3 S3-series bus coupler S3 network-compatible module connectivity
2701222 AXL F BK PN XC PROFINET, XC (extended temperature) PROFINET network integration in extreme temperature environments (-40℃~85℃)
1068857 AXL F BK PN TPS XC PROFINET, TPS function, XC Enhanced PROFINET coupler with TPS for critical applications (extreme temp)
2403869 AXL F BK PN TPS PROFINET, TPS function Enhanced PROFINET coupler with TPS for high-reliability systems
2701815 AXL F BK PN PROFINET, standard configuration Standard PROFINET network integration for AXL F modules
2702463 AXL F BK PB XC PROFIBUS, XC (extended temperature) PROFIBUS network integration in extreme temperature environments
2688530 AXL F BK PB PROFIBUS, standard configuration Standard PROFIBUS network connectivity
2701949 AXL F BK ETH XC Ethernet, XC (extended temperature) Ethernet network integration in harsh environments
2688459 AXL F BK ETH Ethernet, standard configuration Standard Ethernet network connectivity
1167192 AXL F BK EIP XC EtherNet/IP, XC (extended temperature) EtherNet/IP integration in extreme temperature conditions
2702782 AXL F BK EIP EF EtherNet/IP, EF (enhanced function) Enhanced EtherNet/IP coupler with advanced functionality
2688394 AXL F BK EIP EtherNet/IP, standard configuration Standard EtherNet/IP network integration
2688899 AXL F BK EC EC-series bus coupler Specialized EC network module connectivity

2. AXL F Analog Output (AO) Modules

Model No. Product Name Key Features Application Scenarios
2701237 AXL F AO8 XC 1F 8-channel AO, XC (extended temperature), 1F 8-channel analog output in extreme temperature environments
2688080 AXL F AO8 1F 8-channel AO, standard configuration, 1F High-density 8-channel analog output for industrial actuators
2688527 AXL F AO4 1H 4-channel AO, standard configuration, 1H Medium-density 4-channel analog output for process control
2702072 AXL F AI2 AO2 1H 2-channel AI + 2-channel AO, 1H Mixed 2AI/2AO for compact process monitoring and control

3. AXL F Analog Input (AI) Modules

Model No. Product Name Key Features Application Scenarios
2701232 AXL F AI8 XC 1F 8-channel AI, XC (extended temperature), 1F 8-channel analog input in extreme temperature environments
1052434 AXL F AI8 HART XC 1F 8-channel AI, HART communication, XC, 1F HART-enabled 8-channel input for smart sensor integration (extreme temp)
2688064 AXL F AI8 1F 8-channel AI, standard configuration, 1F High-density 8-channel analog input for sensor data acquisition
2702008 AXL F AI4 U XC 1H 4-channel AI (universal), XC, 1H 4-channel universal analog input (voltage/current) in harsh environments
2688501 AXL F AI4 U 1H 4-channel AI (universal), standard configuration, 1H 4-channel universal analog input for versatile sensor connectivity
2702007 AXL F AI4 I XC 1H 4-channel AI (current), XC, 1H 4-channel current-specific analog input (4-20mA) in extreme conditions
2688491 AXL F AI4 I 1H 4-channel AI (current), standard configuration, 1H 4-channel current input for industrial 4-20mA sensors

Core Technical Specifications (Universal)

Parameter Value Notes
Bus Couplers    
Supported Protocols PROFINET, PROFIBUS, Ethernet, EtherNet/IP, SAS, S3, EC Model-dependent
Operating Temperature Standard: -25℃~70℃; XC variants: -40℃~85℃ Extended temp for harsh environments
Mounting Type 35mm DIN rail (NS 35/7.5) Modular system integration
Protection Class IP20 (cabinet mounting) Dust-proof for industrial control cabinets
Isolation Voltage 2kV (input-output-supply) Anti-interference for stable communication
Certifications CE, UL, CSA Global industrial compliance
Analog I/O Modules    
Input/Output Range AI: 4-20mA, 0-10V (universal); AO: 4-20mA, 0-10V Model-dependent
Channel Count 2/4/8-channel (AI/AO); 2AI+2AO (mixed) High-density options for space savings
Resolution 16-bit High-precision signal processing
HART Support Yes (AI8 HART model) Smart sensor communication
Operating Temperature Standard: -25℃~70℃; XC variants: -40℃~85℃ Extended temp for harsh environments
Protection Class IP20 (cabinet mounting) Dust-proof for industrial use
Power Supply 24V DC (19.2~28.8V) Industrial standard power

Application Scenarios & Recommended Models

1. Extreme Temperature PROFINET Integration

  • Requirement: AXL F module integration into PROFINET network in -40℃~85℃ environment
  • Recommended Model: 2701222 (AXL F BK PN XC)
  • Key Reason: XC extended temperature rating; PROFINET protocol compliance for seamless network connectivity

2. HART Smart Sensor Data Acquisition (8-Channel)

  • Requirement: 8-channel analog input with HART communication for smart sensors
  • Recommended Model: 1052434 (AXL F AI8 HART XC 1F)
  • Key Reason: HART support for smart sensor configuration; XC variant for harsh environment deployment

3. Compact Mixed Analog I/O (2AI+2AO)

  • Requirement: Space-saving mixed analog input/output for small-scale process control
  • Recommended Model: 2702072 (AXL F AI2 AO2 1H)
  • Key Reason: 2AI+2AO mixed configuration; compact design optimizes cabinet space

4. EtherNet/IP Enhanced Function Integration

  • Requirement: Enhanced EtherNet/IP connectivity for critical automation processes
  • Recommended Model: 2702782 (AXL F BK EIP EF)
  • Key Reason: EF enhanced function for advanced network features; EtherNet/IP compliance for global compatibility

5. 4-Channel Current-Specific Input (Extreme Temp)

  • Requirement: 4-channel 4-20mA current input in harsh temperature conditions
  • Recommended Model: 2702007 (AXL F AI4 I XC 1H)
  • Key Reason: Current-specific input (4-20mA); XC extended temperature rating for reliable operation

Core Advantages

  • Modular Flexibility: Bus couplers support multiple protocols; analog modules offer 2/4/8-channel and mixed AI/AO options
  • Harsh Environment Adaptability: XC variants operate in -40℃~85℃; ideal for extreme industrial conditions
  • High Precision: 16-bit resolution for analog modules ensures accurate signal processing
  • Smart Sensor Compatibility: HART-enabled AI module supports configuration and communication with smart sensors
  • Seamless Network Integration: Bus couplers cover PROFINET/PROFIBUS/Ethernet/EtherNet/IP for global industrial networks
  • Space-Saving Design: Compact modular layout maximizes control cabinet utilization
  • Industrial-Grade Reliability: 2kV isolation, -25℃~70℃ standard temp range, and IP20 protection

Installation & Usage Notes

  • Protocol Matching: Select bus couplers based on target network protocol (PROFINET/EtherNet/IP etc.)
  • Temperature Verification: Use XC variants for environments outside -25℃~70℃; confirm -40℃~85℃ range for XC models
  • HART Configuration: For AI8 HART model, configure HART parameters via industrial software (e.g., Phoenix Contact PLC Configurator)
  • Analog Signal Wiring: Use shielded twisted-pair cables for analog signals; separate from power cables to reduce interference
  • Module Compatibility: Ensure bus couplers and analog modules are from the AXL F series for seamless integration
  • Mounting Spacing: Reserve ≥5mm between modules for heat dissipation, especially for XC variants
  • Power Supply: Provide stable 24V DC (19.2~28.8V) to all modules; use surge protection for harsh environments
  • Maintenance Checks: Regularly inspect module connections and status indicators; clean terminals periodically to prevent dust buildup

Phoenix AXL F Series: Bus Couplers & Analog I/O Modules - Selection Guide

Created on:2025-11-25 12:01

News Dynamics

NEWS