Phoenix VIP-3/PT Series: FLK & D-Sub Industrial Interface Modules - Selection Guide 

Product Overview

The Phoenix VIP-3/PT Series expands with specialized plug-in terminal (PT) interface modules, focusing on FLK protocol-compatible connectors and D-Sub (D25/D37/D50) interfaces for industrial automation systems. Designed for fast, tool-free wiring (PT terminal design), these modules support diverse connection needs—including FLK64/50/34/14 protocol integration, high-density D-Sub (up to D50) connectivity, hardware-coded (HW/C300) secure matching, and LED status indication. Featuring 35mm DIN rail mounting, robust construction, and compatibility with industrial controllers (e.g., PLCs), they’re ideal for sensor/actuator integration, PLC communication, and secure device matching in manufacturing, process automation, and control cabinet applications.

Model Quick Reference Table

1. VIP-3/PT FLK Protocol Modules

Model No. Product Name Key Features Application Scenarios
2903796 VIP-3/PT/FLK64 PT terminal, FLK64 protocol interface FLK64-compliant device integration (high-speed/signaling)
2903794 VIP-3/PT/FLK50 PT terminal, FLK50 protocol interface FLK50-compatible industrial equipment connectivity
2903792 VIP-3/PT/FLK34 PT terminal, FLK34 protocol interface FLK34-based sensor/actuator signal transmission
2904282 VIP-3/PT/FLK14/8IM/PLC PT terminal, FLK14 protocol, 8IM function, PLC-compatible FLK14-PLC integration with 8-channel interface
2904281 VIP-3/PT/FLK14/8IM/LED/PLC PT terminal, FLK14 protocol, 8IM function, LED indicator, PLC-compatible FLK14-PLC connectivity with visual status monitoring

2. VIP-3/PT D-Sub Interface Modules (D25/D37/D50)

Model No. Product Name Key Features Application Scenarios
2903785 VIP-3/PT/D50SUB/M PT terminal, D50SUB male connector High-density D50 male connection for industrial controllers
2903786 VIP-3/PT/D50SUB/F PT terminal, D50SUB female connector High-density D50 female connectivity for heavy-duty equipment
2904276 VIP-3/PT/D37SUB/M/HW/C300 PT terminal, D37SUB male, HW hardware coding (C300) Secure D37 male connection with hardware-matched C300 compatibility
2903783 VIP-3/PT/D37SUB/M PT terminal, D37SUB male connector Standard D37 male interface for PLC/sensor integration
2903784 VIP-3/PT/D37SUB/F PT terminal, D37SUB female connector Standard D37 female connectivity for industrial devices
2903781 VIP-3/PT/D25SUB/M PT terminal, D25SUB male connector Compact D25 male connection for medium-density signals
2903782 VIP-3/PT/D25SUB/F PT terminal, D25SUB female connector Compact D25 female interface for space-constrained setups

Core Technical Specifications (Universal)

Parameter Value Notes
Terminal Type PT (Plug-in) Tool-free wiring, 0.14~2.5mm² conductor compatibility
Interface Types FLK (64/50/34/14), D-Sub (D25/D37/D50, M/F) Model-dependent protocol/connector options
Operating Temperature -25℃~70℃ Industrial-grade temperature tolerance
Mounting Type 35mm DIN rail (NS 35/7.5) Compact design for space-saving cabinet layout
Protection Class IP20 (cabinet mounting) Dust-proof for industrial control cabinets
Key Functions Hardware coding (HW/C300), LED status indication, PLC compatibility Model-dependent enhanced features
Insulation Voltage 2kV (input-output) Anti-interference for stable signal transmission
Certifications CE, UL, CSA Global industrial compliance
Mechanical Strength Tensile strength ≥10N (connector) Resists cable pull-out and vibration

Application Scenarios & Recommended Models

1. FLK14-PLC Integration with Status Monitoring

  • Requirement: FLK14 protocol connectivity between PLC and 8-channel industrial devices (with visual feedback)
  • Recommended Model: 2904281 (VIP-3/PT/FLK14/8IM/LED/PLC)
  • Key Reason: 8IM function for multi-channel integration; LED indicator for real-time status; PLC compatibility

2. Secure D37 Male Connection (Hardware-Coded)

  • Requirement: Hardware-matched D37 male connection for C300-compatible devices
  • Recommended Model: 2904276 (VIP-3/PT/D37SUB/M/HW/C300)
  • Key Reason: HW/C300 hardware coding prevents incorrect connections; PT terminal for fast wiring

3. High-Density D50 Female Connectivity

  • Requirement: High-channel D50 female interface for heavy-duty industrial equipment
  • Recommended Model: 2903786 (VIP-3/PT/D50SUB/F)
  • Key Reason: D50 high-density design; PT plug-in terminal for tool-free maintenance

4. Compact D25 Male Signal Transmission

  • Requirement: Space-saving D25 male connection for medium-density sensor signals
  • Recommended Model: 2903781 (VIP-3/PT/D25SUB/M)
  • Key Reason: Compact D25 form factor; PT terminal for quick deployment in tight cabinets

5. FLK34 Protocol Sensor Integration

  • Requirement: FLK34-compatible interface for industrial sensors
  • Recommended Model: 2903792 (VIP-3/PT/FLK34)
  • Key Reason: FLK34 protocol compliance; PT plug-in terminal for easy sensor wiring

Core Advantages

  • Tool-Free PT Terminals: Plug-in design enables fast wiring/maintenance (no crimping/screwdrivers required)
  • Diverse Protocol/Connector Support: FLK (64/50/34/14) and D-Sub (D25/D37/D50) cover varied industrial interfaces
  • Secure Hardware Coding: HW/C300 variant prevents incorrect device connections (critical for safety-critical systems)
  • Visual Status Monitoring: LED-equipped models provide real-time signal feedback
  • Industrial-Grade Reliability: -25℃~70℃ operating temperature, 2kV isolation, and vibration-resistant design
  • PLC Compatibility: FLK14/8IM/PLC variants ensure seamless integration with industrial controllers
  • Space-Saving Design: DIN rail mounting and compact form factor optimize control cabinet utilization

Installation & Usage Notes

  • PT Terminal Wiring: Use 0.14~2.5mm² conductors; insert wires directly into PT terminals (tool-free locking)
  • Hardware Coding Matching: For HW/C300 models (2904276), ensure compatibility with C300-coded target devices
  • Connector Gender Verification: Confirm D-Sub gender (M/F) matches target equipment to avoid connection issues
  • FLK Protocol Configuration: For FLK models, verify protocol version (64/50/34/14) with connected devices
  • LED Indicator Check: Post-installation, confirm LED functionality (if equipped) to ensure signal transmission
  • Mounting Spacing: Reserve ≥3mm between modules for heat dissipation and cable routing
  • Environmental Protection: Install in dry, dust-free control cabinets (IP20 protection); avoid moisture/corrosive substances
  • Cable Selection: Use shielded cables for FLK/D-Sub signals to reduce EMI interference (critical for high-speed protocols)