Phoenix VAL-US Series: Industrial Power Distribution Units (PDUs) - Selection Guide
Product Overview
The Phoenix VAL-US Series comprises industrial-grade power distribution units (PDUs) designed for reliable AC power distribution in automation systems, control cabinets, and critical infrastructure. Covering input voltage ranges from 120V AC to 480V AC, with current ratings from 30A to 80A and output configurations (e.g., 3+1V, 3+0, 4+0, 1+1), these PDUs feature FM certification for hazardous area compatibility, robust construction, and flexible mounting options. Ideal for North American power grids (120/240/277/347/480V AC), they ensure safe, efficient power distribution for industrial equipment, PLCs, sensors, and actuators in manufacturing, process automation, and commercial buildings.
Model Quick Reference Table
1. 480V AC Input PDUs
| Model No. |
Product Name |
Input Voltage |
Current Rating |
Output Configuration |
Key Features |
Application Scenarios |
| 2910387 |
VAL-US-480HLD/30/3+1V-FM |
480V AC (HLD) |
30A |
3+1V (3-phase + neutral + ground) |
FM certified |
Hazardous area 3-phase 480V AC power distribution |
| 2910386 |
VAL-US-480D/30/3+0-FM |
480V AC (dual-voltage) |
30A |
3+0 (3-phase + ground) |
FM certified, dual-voltage |
Dual-voltage 3-phase 480V AC distribution (delta config) |
2. 347V AC Input PDUs
| Model No. |
Product Name |
Input Voltage |
Current Rating |
Output Configuration |
Key Features |
Application Scenarios |
| 1079099 |
VAL-US-347/30/3+1V-FM |
347V AC |
30A |
3+1V |
FM certified |
Hazardous area 3-phase 347V AC power distribution (wye) |
| 2910383 |
VAL-US-347/30/3+0-FM |
347V AC |
30A |
3+0 |
FM certified |
Hazardous area 3-phase 347V AC distribution (delta) |
3. 277V AC Input PDUs
| Model No. |
Product Name |
Input Voltage |
Current Rating |
Output Configuration |
Key Features |
Application Scenarios |
| 2910380 |
VAL-US-277/80/4+0-FM |
277V AC |
80A |
4+0 (4-phase + ground) |
FM certified, high current |
Heavy-load 277V AC power distribution (hazardous area) |
| 1075896 |
VAL-US-277/80/3+0-FM |
277V AC |
80A |
3+0 |
FM certified, high current |
Heavy-load 3-phase 277V AC distribution (delta) |
| 2910377 |
VAL-US-277/80/1+0-FM |
277V AC |
80A |
1+0 (1-phase + ground) |
FM certified, single-phase |
High-current single-phase 277V AC distribution |
| 2910338 |
VAL-US-277/40-P |
277V AC |
40A |
- |
Specialized protection (P-suffix) |
277V AC power distribution with enhanced protection |
| 2910374 |
VAL-US-277/40/3+1-FM |
277V AC |
40A |
3+1 (3-phase + neutral + ground) |
FM certified |
Hazardous area 40A 277V AC distribution (wye) |
| 1199369 |
VAL-US-277/40/3+0-FM |
277V AC |
40A |
3+0 |
FM certified |
Hazardous area 40A 277V AC distribution (delta) |
| 2910373 |
VAL-US-277/40/1+1-FM |
277V AC |
40A |
1+1 (1-phase + neutral + ground) |
FM certified |
Hazardous area single-phase 277V AC distribution |
4. 240V AC Input PDUs
| Model No. |
Product Name |
Input Voltage |
Current Rating |
Output Configuration |
Key Features |
Application Scenarios |
| 2910370 |
VAL-US-240D/40/3+0-FM |
240V AC (dual-voltage) |
40A |
3+0 |
FM certified, dual-voltage |
Dual-voltage 3-phase 240V AC distribution (delta) |
| 2910369 |
VAL-US-240D/40/2+0-FM |
240V AC (dual-voltage) |
40A |
2+0 (2-phase + ground) |
FM certified, dual-voltage |
Dual-voltage 2-phase 240V AC distribution |
| 2910367 |
VAL-US-240/40/3+1-FM |
240V AC |
40A |
3+1 (3-phase + neutral + ground) |
FM certified |
Hazardous area 3-phase 240V AC distribution (wye) |
| 2910362 |
VAL-US-240/40/1+1-FM |
240V AC |
40A |
1+1 |
FM certified |
Hazardous area single-phase 240V AC distribution |
| 2910361 |
VAL-US-240/40/1+0-FM |
240V AC |
40A |
1+0 |
FM certified |
Hazardous area single-phase 240V AC distribution (no neutral) |
5. 120V AC Input PDUs
| Model No. |
Product Name |
Input Voltage |
Current Rating |
Output Configuration |
Key Features |
Application Scenarios |
| 2910360 |
VAL-US-120/65/3+1-FM |
120V AC |
65A |
3+1 (3-phase + neutral + ground) |
FM certified, high current |
Hazardous area high-current 120V AC distribution (wye) |
| 2910353 |
VAL-US-120/40/3+0-FM |
120V AC |
40A |
3+0 |
FM certified |
Hazardous area 3-phase 120V AC distribution (delta) |
| 2910349 |
VAL-US-120/40/1+1-FM |
120V AC |
40A |
1+1 |
FM certified |
Hazardous area single-phase 120V AC distribution |
Core Technical Specifications (Universal)
| Parameter |
Value |
Notes |
| Input Voltage Range |
120V AC, 240V AC (D-suffix: 120/240V), 277V AC, 347V AC, 480V AC (D-suffix: 277/480V) |
North American grid compatibility |
| Current Rating |
30A, 40A, 65A, 80A |
Model-dependent maximum load capacity |
| Output Configuration |
3+1V, 3+0, 4+0, 1+1 |
Phase/neutral/ground combinations for diverse topologies |
| Protection Functions |
Overcurrent, short-circuit, overload |
Comprehensive power protection |
| Certification |
FM Global (FM-suffix) |
Hazardous area compliance (Class I/II/III, Div 2) |
| Operating Temperature |
-20℃~60℃ |
Industrial-grade temperature tolerance |
| Mounting Type |
Wall-mount, DIN rail (model-dependent) |
Flexible installation options |
| Protection Class |
IP20 (cabinet mounting) |
Dust-proof for industrial control cabinets |
| Conductor Size |
Input: 6AWG~2AWG; Output: 12AWG~6AWG |
Compatible with standard industrial cables |
| Voltage Drop |
≤3% at full load |
Minimal power loss for efficient distribution |
Application Scenarios & Recommended Models
1. Hazardous Area 3-Phase 480V AC Distribution (30A)
- Requirement: FM-certified 3-phase power distribution for 480V AC equipment in hazardous areas
- Recommended Model: 2910387 (VAL-US-480HLD/30/3+1V-FM)
- Key Reason: 3+1V wye configuration; FM certification; 30A capacity for medium-load applications
2. Heavy-Load 277V AC Distribution (80A, Hazardous Area)
- Requirement: High-current 277V AC power distribution for heavy industrial equipment
- Recommended Model: 2910380 (VAL-US-277/80/4+0-FM)
- Key Reason: 80A high current; 4+0 configuration; FM certification for hazardous area use
3. Dual-Voltage 240V AC Distribution (40A, 3-Phase)
- Requirement: Dual-voltage compatible 3-phase 240V AC distribution (delta configuration)
- Recommended Model: 2910370 (VAL-US-240D/40/3+0-FM)
- Key Reason: D-suffix dual-voltage support; 3+0 delta configuration; FM certification
4. Single-Phase 120V AC Distribution (40A, Hazardous Area)
- Requirement: Safe single-phase power distribution for 120V AC sensors/PLCs in hazardous areas
- Recommended Model: 2910349 (VAL-US-120/40/1+1-FM)
- Key Reason: 1+1 single-phase + neutral + ground; FM certification; 40A capacity
5. Enhanced Protection 277V AC Distribution (40A)
- Requirement: 277V AC power distribution with specialized protection features
- Recommended Model: 2910338 (VAL-US-277/40-P)
- Key Reason: P-suffix specialized protection; 40A capacity for critical systems
Core Advantages
- North American Grid Compatibility: Supports 120/240/277/347/480V AC (dual-voltage options for flexibility)
- Hazardous Area Compliance: FM certification enables deployment in Class I/II/III, Div 2 environments
- Diverse Output Configurations: 3+1V/3+0/4+0/1+1 fit 3-phase/single-phase, wye/delta topologies
- High Current Capacity: Up to 80A rating for heavy-load industrial applications
- Robust Protection: Overcurrent/short-circuit/overload protection safeguards equipment
- Flexible Mounting: Wall-mount and DIN rail options adapt to control cabinet/plant floor installations
- Efficient Power Distribution: ≤3% voltage drop ensures minimal power loss
Installation & Usage Notes
- Voltage Compatibility: Verify input voltage matches PDU rating (D-suffix models support dual voltages)
- Output Configuration Matching: Select 3+1V (wye) for systems requiring neutral; 3+0 (delta) for 3-phase-only loads
- Hazardous Area Installation: FM-suffix models must comply with Class I/II/III, Div 2 wiring guidelines (proper grounding, approved cables)
- Conductor Sizing: Use recommended wire gauges (input: 6AWG~2AWG; output: 12AWG~6AWG) to avoid overheating
- Mounting: Ensure secure wall-mount/DIN rail installation; allow ≥10cm clearance for heat dissipation
- Load Balancing: Distribute loads evenly across phases for 3-phase models to prevent phase imbalance
- Maintenance Checks: Regularly inspect terminal connections, circuit breakers, and FM certification labels; replace damaged components promptly