Phoenix ST-OV/ST-OE Series: Industrial Overvoltage Protection & Signal Conversion Modules - Selection Guide 

Product Overview

The Phoenix ST-OV (Overvoltage Protection) and ST-OE (Signal Conversion) Series encompass specialized industrial modules designed for overvoltage suppression and DC-DC signal conversion in automation systems. The ST-OV Series (3-channel OV3, 2-channel OV2) provides reliable overvoltage protection for DC/AC circuits, supporting input/output voltages from 5V DC to 400V AC and current ratings up to 5A. The ST-OE Series (3-channel OE3, 2-channel OE2) focuses on DC-DC signal conversion with fixed 48V DC output and 100mA current, ideal for standardizing sensor/actuator signals. Featuring 35mm DIN rail mounting, robust isolation, and industrial-grade durability, these modules ensure equipment safety and signal stability in manufacturing, process automation, and control cabinet applications.

Model Quick Reference Table

1. ST-OV3 Series (3-Channel Overvoltage Protection)

Model No. Product Name Input Voltage Output Voltage Current Rating Key Features Application Scenarios
2905417 ST-OV3-24DC/400AC/3 24V DC 400V AC 3A 3-channel, AC output protection 24V DC-controlled 400V AC circuit overvoltage suppression
2903202 ST-OV3-24DC/220DC/1 24V DC 220V DC 1A 3-channel, DC output protection 24V DC to 220V DC circuit overvoltage protection
2903176 ST-OV3-220DC/220DC/1 220V DC 220V DC 1A 3-channel, same-voltage protection 220V DC system overvoltage suppression
2905174 ST-OV3-5DC/24DC/2 5V DC 24V DC 2A 3-channel, DC-DC protection 5V DC to 24V DC signal overvoltage protection
2903228 ST-OV3-24DC/60DC/3 24V DC 60V DC 3A 3-channel, high-current protection 24V DC to 60V DC high-current circuit protection
2905190 ST-OV3-24DC/24DC/2 24V DC 24V DC 2A 3-channel, same-voltage protection 24V DC control circuit overvoltage suppression

2. ST-OV2 Series (2-Channel Overvoltage Protection)

Model No. Product Name Input Voltage Output Voltage Current Rating Key Features Application Scenarios
2905035 ST-OV2-24DC/60DC/1 24V DC 60V DC 1A 2-channel, DC-DC protection 24V DC to 60V DC small-signal overvoltage protection
2905051 ST-OV2-110DC/60DC/1 110V DC 60V DC 1A 2-channel, step-down protection 110V DC to 60V DC circuit overvoltage suppression
2905048 ST-OV2-60DC/60DC/1 60V DC 60V DC 1A 2-channel, same-voltage protection 60V DC system overvoltage protection
2905491 ST-OV2-24DC/24DC/5 24V DC 24V DC 5A 2-channel, high-current protection 24V DC high-power circuit overvoltage suppression
2905022 ST-OV2-12DC/60DC/1 12V DC 60V DC 1A 2-channel, step-up protection 12V DC to 60V DC signal overvoltage protection

3. ST-OE3 Series (3-Channel DC-DC Signal Conversion)

Model No. Product Name Input Voltage Output Voltage Current Rating Key Features Application Scenarios
2911045 ST-OE3-60DC/48DC/100 60V DC 48V DC 100mA 3-channel, step-down conversion 60V DC to 48V DC sensor signal standardization
2911074 ST-OE3-5DC/48DC/100 5V DC 48V DC 100mA 3-channel, step-up conversion 5V DC to 48V DC actuator signal conversion
2911058 ST-OE3-24DC/48DC/100 24V DC 48V DC 100mA 3-channel, step-up conversion 24V DC to 48V DC industrial signal conversion

4. ST-OE2 Series (2-Channel DC-DC Signal Conversion)

Model No. Product Name Input Voltage Output Voltage Current Rating Key Features Application Scenarios
2911728 ST-OE2-220DC/48DC/100 220V DC 48V DC 100mA 2-channel, step-down conversion 220V DC to 48V DC high-voltage signal standardization
2911692 ST-OE2-24DC/48DC/100 24V DC 48V DC 100mA 2-channel, step-up conversion 24V DC to 48V DC sensor/actuator signal conversion

Core Technical Specifications (Universal)

Parameter ST-OV Series (Overvoltage Protection) ST-OE Series (Signal Conversion) Notes
Input Voltage Range 5V DC~220V DC, 24V DC~400V AC 5V DC~220V DC OV supports AC/DC; OE DC-only
Output Voltage Matches input (protection) or fixed 48V DC (conversion) Fixed 48V DC ±1% OE provides standardized 48V DC output
Current Rating 1A~5A 100mA (per channel) OV handles higher currents; OE for low-power signals
Protection Functions Overvoltage, transient surge, reverse polarity Overvoltage, short-circuit OV: ≤10ns surge response; OE: overload protection
Isolation Voltage 4kV (input-output) 2kV (input-output) Anti-interference for control systems
Operating Temperature -25℃~70℃ -25℃~70℃ Industrial-grade temperature tolerance
Mounting Type 35mm DIN rail (NS 35/7.5) 35mm DIN rail (NS 35/7.5) Compact space-saving installation
Protection Class IP20 (cabinet mounting) IP20 (cabinet mounting) Dust-proof for industrial control cabinets
Certifications CE, UL, CSA CE, UL, CSA Global industrial compliance
Conversion Accuracy N/A ≤±0.5% FS OE ensures precise signal standardization

Application Scenarios & Recommended Models

1. 24V DC High-Current Overvoltage Protection (5A)

  • Requirement: 2-channel overvoltage suppression for 24V DC high-power circuits
  • Recommended Model: 2905491 (ST-OV2-24DC/24DC/5)
  • Key Reason: 5A high-current capacity; same-voltage protection for 24V DC systems

2. 24V DC to 48V DC Signal Conversion (3-Channel)

  • Requirement: 3-channel step-up conversion for standardizing 24V DC sensor signals to 48V DC
  • Recommended Model: 2911058 (ST-OE3-24DC/48DC/100)
  • Key Reason: 3-channel density; 100mA output; ≤±0.5% conversion accuracy

3. 400V AC Circuit Overvoltage Protection (24V DC Control)

  • Requirement: 3-channel overvoltage protection for 400V AC circuits controlled by 24V DC
  • Recommended Model: 2905417 (ST-OV3-24DC/400AC/3)
  • Key Reason: AC/DC cross-protection; 3A current rating; 4kV isolation

4. 60V DC System Overvoltage Protection (2-Channel)

  • Requirement: 2-channel overvoltage suppression for 60V DC industrial systems
  • Recommended Model: 2905048 (ST-OV2-60DC/60DC/1)
  • Key Reason: Same-voltage protection; compact 2-channel design

5. 220V DC to 48V DC High-Voltage Conversion (2-Channel)

  • Requirement: 2-channel step-down conversion for 220V DC high-voltage signals to 48V DC
  • Recommended Model: 2911728 (ST-OE2-220DC/48DC/100)
  • Key Reason: High-input voltage compatibility; 100mA standardized output

Core Advantages

  • Dual Functional Series: OV (overvoltage protection) and OE (signal conversion) cover complementary system needs
  • Wide Voltage Coverage: 5V DC~400V AC input/output fits diverse industrial circuits
  • Channel Flexibility: 2-channel/3-channel options optimize space for small-to-medium scale applications
  • Industrial-Grade Reliability: -25℃~70℃ operating temperature, 2kV~4kV isolation, and IP20 protection
  • Precision Conversion: OE series with ≤±0.5% accuracy ensures standardized signal output
  • High-Current Support: OV series up to 5A handles high-power circuit protection
  • Easy Installation: 35mm DIN rail mounting and standardized wiring for quick deployment
  • Global Compliance: CE/UL/CSA certifications enable international deployment

Installation & Usage Notes

  • Voltage Matching: Ensure input/output voltage aligns with module ratings (OV supports AC/DC; OE is DC-only)
  • Current Limitation: Do not exceed OV current rating (1A~5A) or OE 100mA per channel limit
  • Wiring Specifications: Use 0.5~2.5mm² conductors for OV (high-current) and 0.14~0.75mm² for OE (low-current)
  • Isolation Wiring: Separate input/output wiring by ≥10mm to maximize isolation effectiveness
  • Mounting Spacing: Reserve ≥5mm between modules for heat dissipation, especially for OV high-current variants
  • Surge Protection Placement: Install OV modules close to protected devices for optimal transient suppression
  • Conversion Calibration: For OE models, verify 48V DC output post-installation (±1% tolerance)
  • Environmental Protection: Install in dry, dust-free control cabinets (IP20 protection); avoid moisture/corrosive substances

Phoenix ST-OV/ST-OE Series: Industrial Overvoltage Protection & Signal Conversion Modules - Selection Guide

Created on:2025-11-26 11:29

News Dynamics

NEWS