Phoenix PT-IQ Series: Industrial Signal Distribution & Isolation Modules - Selection Guide 

Product Overview

The Phoenix PT-IQ Series comprises compact, high-reliability signal distribution and isolation modules designed for industrial automation systems. Focusing on 1×2 channel configuration (1 input → 2 isolated outputs), these modules support control voltages from 5V DC to 48V DC, with flexible terminal options (PT plug-in/UT universal), functional variants (F-suffix enhanced features), and hazardous area compliance (EX-suffix). Ideal for sensor signal distribution, PLC input duplication, and isolated signal transmission, they feature 35mm DIN rail mounting, robust galvanic isolation, and industrial-grade durability to ensure signal integrity and system safety in manufacturing, process automation, and control cabinet applications.

Model Quick Reference Table

Model No. Product Name Key Features Application Scenarios
2801514 PT-IQ-1X2-EX-24DC-P 1×2 channel, 24V DC, EX explosion-proof, P-suffix Hazardous area (Zone 2) 24V DC signal distribution with isolation
2800770 PT-IQ-1X2-5DC-P 1×2 channel, 5V DC, P-suffix 5V DC microcontroller signal distribution (2 isolated outputs)
2801257 PT-IQ-1X2-48DC-PT 1×2 channel, 48V DC, PT plug-in terminal 48V DC signal distribution with tool-free wiring (fast maintenance)
2800773 PT-IQ-1X2-48DC-P 1×2 channel, 48V DC, P-suffix Standard 48V DC signal distribution (industrial actuators)
2800976 PT-IQ-1X2-24DC-UT 1×2 channel, 24V DC, UT universal terminal 24V DC signal distribution with universal screw wiring (secure connection)
2801255 PT-IQ-1X2-24DC-PT 1×2 channel, 24V DC, PT plug-in terminal 24V DC sensor signal distribution (tool-free installation)
2800772 PT-IQ-1X2-24DC-P 1×2 channel, 24V DC, P-suffix Standard 24V DC signal distribution (PLC input duplication)
2800771 PT-IQ-1X2-12DC-P 1×2 channel, 12V DC, P-suffix 12V DC low-voltage signal distribution (compact electronics)
2800977 PT-IQ-1X2+F-24DC-UT 1×2 channel, 24V DC, F-enhanced function, UT terminal Enhanced 24V DC signal distribution (filtering/protection + universal wiring)
2801256 PT-IQ-1X2+F-24DC-PT 1×2 channel, 24V DC, F-enhanced function, PT terminal Enhanced 24V DC signal distribution (filtering + tool-free wiring)

Core Technical Specifications (Universal)

Parameter Value Notes
Channel Configuration 1 input → 2 isolated outputs (1X2) Signal duplication with galvanic isolation
Input/Output Voltage 5V DC, 12V DC, 24V DC, 48V DC (±10% tolerance) Industrial standard low-voltage power
Terminal Types PT (plug-in): Tool-free, 0.14~2.5mm²; UT (universal): Screw, 0.14~2.5mm² PT for fast maintenance; UT for vibration-prone environments
Isolation Voltage 3kV (input-output; output-output) Prevents cross-interference between dual outputs
Operating Temperature Standard: -25℃~70℃; EX models: -20℃~60℃ Industrial-grade temperature tolerance
Mounting Type 35mm DIN rail (NS 35/7.5) Compact design (6.2mm width) for space-saving cabinet layout
Protection Class IP20 (cabinet mounting); EX models: IP20 + ATEX/IECEx Dust-proof; EX for Zone 2 hazardous areas
Certifications CE, UL, CSA; EX models: ATEX/IECEx (Zone 2) Global industrial and hazardous area compliance
Current Rating ≤3A per output Supports standard industrial sensor/actuator signals
Response Time ≤1μs Fast signal transmission for real-time control
Enhanced Function (F-suffix) Signal filtering, surge protection Reduces EMI interference for sensitive applications

Application Scenarios & Recommended Models

1. Hazardous Area Signal Distribution (24V DC)

  • Requirement: 1×2 channel signal distribution in Zone 2 explosive environments
  • Recommended Model: 2801514 (PT-IQ-1X2-EX-24DC-P)
  • Key Reason: EX certification for Zone 2; 3kV isolation; 24V DC compatibility with industrial sensors

2. Tool-Free 24V DC Signal Distribution

  • Requirement: Fast-install 24V DC sensor signal distribution for PLC input duplication
  • Recommended Model: 2801255 (PT-IQ-1X2-24DC-PT)
  • Key Reason: PT plug-in terminal (tool-free wiring); 1×2 configuration for dual-output needs

3. Enhanced Signal Distribution (24V DC, Filtering)

  • Requirement: Noise-suppressed 24V DC signal distribution with secure wiring
  • Recommended Model: 2800977 (PT-IQ-1X2+F-24DC-UT)
  • Key Reason: F-suffix signal filtering; UT universal terminal for vibration-resistant connections

4. 48V DC High-Voltage Signal Distribution

  • Requirement: 48V DC industrial actuator signal distribution with tool-free maintenance
  • Recommended Model: 2801257 (PT-IQ-1X2-48DC-PT)
  • Key Reason: 48V DC compatibility; PT plug-in terminal for quick wiring adjustments

5. 5V DC Microcontroller Signal Duplication

  • Requirement: 5V DC low-voltage signal distribution for microcontroller-based systems
  • Recommended Model: 2800770 (PT-IQ-1X2-5DC-P)
  • Key Reason: 5V DC precision; 3kV isolation to protect sensitive electronics

Core Advantages

  • 1×2 Isolated Distribution: 1 input → 2 isolated outputs eliminates cross-interference
  • Wide Voltage Compatibility: 5V DC~48V DC covers low/high industrial control voltages
  • Flexible Terminal Options: PT (tool-free) for fast deployment; UT (screw) for secure wiring
  • Hazardous Area Compliance: EX-suffix models enable Zone 2 deployment
  • Enhanced Functionality: F-suffix provides signal filtering/surge protection for noisy environments
  • Ultra-Compact Design: 6.2mm width maximizes control cabinet density
  • Industrial-Grade Reliability: 3kV isolation, -25℃~70℃ operating range, and IP20 protection
  • Global Compliance: CE/UL/CSA/EX certifications support international applications

Installation & Usage Notes

  • Voltage Matching: Ensure module voltage aligns with input/output signal voltage (5/12/24/48V DC)
  • EX Model Deployment: Install EX-suffixed models per ATEX/IECEx guidelines (proper grounding, Zone 2 restriction)
  • Terminal Selection: Use PT terminals for frequent maintenance; UT terminals for high-vibration environments
  • Isolation Wiring: Separate input and output wiring by ≥10mm to maintain 3kV isolation effectiveness
  • Current Limitation: Do not exceed 3A per output (suitable for standard sensors/actuators)
  • F-Suffix Setup: For F-enhanced models, refer to datasheet for signal filtering configuration (if applicable)
  • Mounting Spacing: Reserve ≥3mm between modules for heat dissipation and cable routing
  • Environmental Protection: Install in dry, dust-free control cabinets (IP20 protection); avoid moisture/corrosive substances