Phoenix VAL-SEC-T2 Series: T2 Class Surge Protection Devices (SPDs) - Comprehensive Application & Selection Guide

Product Positioning & Core Value

The Phoenix VAL-SEC-T2 Series represents a high-performance lineup of Type 2 surge protection devices (SPDs) engineered to safeguard industrial power systems, electrical infrastructure, and sensitive equipment from transient voltage surges. As critical components in surge protection layers, these modules mitigate risks from switching operations, lightning-induced disturbances, and grid fluctuations, ensuring uninterrupted operation of power distribution systems. With versatile configurations for AC/DC power networks, multiple pole designs (1S~3C), wide voltage ratings (120DC~440V AC), and functional variants (FM Global certification, variable frequency compatibility, high-surge capacity), the series is ideal for industrial facilities, commercial buildings, hazardous areas, and renewable energy systems. Its robust design, compliance with IEC 61643-12, and 35mm DIN rail mounting make it a reliable choice for harsh industrial environments and critical power infrastructure.

Product Family Overview

The VAL-SEC-T2 Series is categorized by pole configuration, voltage type (AC/DC), and functional features to meet diverse application needs:

1. AC Surge Protection Modules

  • Function: Protect AC power systems (single-phase/three-phase) from transient surges.
  • Pole Configurations: 1S (1-pole + PE), 2S (2-pole + PE), 3S (3-pole + PE), 3C (3-pole + N + PE), N/PE (Neutral + PE).
  • Voltage Ratings: 175V, 350V, 440V AC.
  • Functional Variants:
    • FM: FM Global certified (hazardous area compliant, Class I/II/III, Div 2).
    • P: Standard performance (general industrial applications).
    • VF: Variable frequency compatible (for inverter-driven systems).
  • Typical Models: VAL-SEC-T2-3S-350-FM, VAL-SEC-T2-N/PE-350-P, VAL-SEC-T2-3C-440-FM.

2. DC Surge Protection Modules

  • Function: Safeguard DC power systems (batteries, solar PV, industrial DC circuits) from surges.
  • Pole Configurations: 2+0 (2-pole, no PE), 2+F (2-pole + filter).
  • Voltage Ratings: 48DC, 120DC, 220DC, 380DC.
  • Functional VariantsFM (hazardous area compliant), P (standard performance).
  • Typical Models: VAL-SEC-T2-2+0-48DC-FM, VAL-SEC-T2-220DC-P, VAL-SEC-T2-2+F-48DC-FM.

Technical Specifications (Universal Parameters)

Parameter Category Technical Indicators Notes
Electrical Characteristics    
Rated Voltage (Uc) AC: 175V, 350V, 440VDC: 48V, 120V, 220V, 380V Matches grid voltage requirements
Surge Current Capacity (Iimp) Up to 350kA (8/20μs waveform) Varies by model (175kA/350kA)
Protection Level (Up) ≤1.2kV (AC models)≤1.5kV (DC models) Low clamping voltage for sensitive equipment
Response Time ≤25ns Fast surge suppression to minimize damage
Polarity AC: BidirectionalDC: Unidirectional Optimized for voltage type
Mechanical Characteristics    
Mounting Type 35mm DIN rail (NS 35/7.5) Space-saving cabinet installation
Housing Material Polyamide PA (Flame-retardant V0 grade) Resistance to high temperature and impact
Protection Class IP20 (cabinet mounting) Dust and solid particle protection
Operating Temperature -40°C to +85°C Wide range for harsh industrial environments
Storage Temperature -40°C to +90°C Stable storage performance
Compliance & Safety    
Certifications CE, UL 1449 (4th Edition), CSA, FM Global (FM models) Global industrial and hazardous area compliance
Standards IEC 61643-12, EN 61643-12 Meets international surge protection standards
Indicator Visual status LED (green = normal; red = faulty) Easy fault detection and maintenance

Detailed Function Module Introduction

1. AC Surge Protection Modules (Pole Configurations)

1.1 Single-Phase & Neutral-PE Modules

Model Order No. Core Functions Technical Highlights Application Scenarios
VAL-SEC-T2-N/PE-350-P 2905347 N/PE surge protection, 350kA capacity Standard P-variant, 350kA Iimp, IP20 Single-phase AC systems (neutral-ground surge mitigation)
VAL-SEC-T2-1S-350-FM 2905333 1-pole + PE, FM certified, 350kA capacity Hazardous area compliant, 8/20μs waveform Explosive environments (Div 2) single-phase systems
VAL-SEC-T2-1S-175-FM 2905348 1-pole + PE, FM certified, 175kA capacity Cost-effective FM option, 175kA Iimp Light-duty single-phase systems in hazardous areas

1.2 Two-Phase Modules

Model Order No. Core Functions Technical Highlights Application Scenarios
VAL-SEC-T2-2S-350 2905343 2-pole + PE, 350kA capacity Standard performance, 2-pole protection Two-phase AC systems (industrial machinery, pumps)
VAL-SEC-T2-2C-350-FM 2905337 2-pole + N + PE, FM certified, 350kA capacity Neutral-included protection, hazardous area compliance Two-phase systems with neutral (building electrical infrastructure)
VAL-SEC-T2-2S-175-FM 2905351 2-pole + PE, FM certified, 175kA capacity Low-surge capacity, cost-effective Light-load two-phase systems in hazardous areas

1.3 Three-Phase Modules

Model Order No. Core Functions Technical Highlights Application Scenarios
VAL-SEC-T2-3S-350-FM 2905340 3-pole + PE, FM certified, 350kA capacity 3-phase protection, hazardous area compliant Heavy-duty industrial 3-phase systems (motors, inverters)
VAL-SEC-T2-3C-350 2905344 3-pole + N + PE, 350kA capacity Neutral-included protection, standard variant 3-phase 4-wire systems (power distribution panels)
VAL-SEC-T2-3S-350VF-FM 2909590 3-pole + PE, VF variable frequency, FM certified Inverter-compatible, 350kA Iimp Variable frequency drive (VFD) systems, renewable energy
VAL-SEC-T2-3S-350/40-FM 2909635 3-pole + PE, 350kA/40kA dual capacity Dual surge rating, FM certified Mixed-load 3-phase systems (heavy + sensitive equipment)

2. DC Surge Protection Modules

Model Order No. Core Functions Technical Highlights Application Scenarios
VAL-SEC-T2-220DC-P 2907879 2-pole DC protection, 220V DC Standard P-variant, IP20, ≤1.5kV Up Industrial DC systems (batteries, DC motors)
VAL-SEC-T2-2+0-48DC-FM 2907865 2-pole DC, FM certified, 48V DC Hazardous area compliant, no PE 48V DC systems in explosive environments (sensors, communication equipment)
VAL-SEC-T2-2+F-48DC-FM 1033786 2-pole DC + filter, FM certified, 48V DC Integrated filtering, surge protection Sensitive 48V DC systems (PLCs, control circuits) in hazardous areas
VAL-SEC-T2-2+0-380DC-FM 2907876 2-pole DC, FM certified, 380V DC High-voltage DC protection Solar PV systems, high-voltage DC power distribution

Application Scenario Analysis

1. Industrial Power Distribution Systems

Recommended Configuration:

  • 3-Phase 4-Wire Systems: VAL-SEC-T2-3C-350-FM (2905339)
  • 3-Phase VFD Systems: VAL-SEC-T2-3S-350VF-FM (2909590)
  • Single-Phase Auxiliary Systems: VAL-SEC-T2-N/PE-350-P (2905347)

Implementation Advantages:

  • 350kA surge capacity withstands heavy industrial transient surges.
  • VF variant compatibility with inverter-driven equipment (motors, pumps).
  • FM certification enables deployment in hazardous production areas (chemical, oil & gas).

2. Hazardous Area Electrical Infrastructure

Recommended Configuration:

  • AC Systems: VAL-SEC-T2-3S-350-FM (2905340), VAL-SEC-T2-1S-350-FM (2905333)
  • DC Systems: VAL-SEC-T2-2+0-48DC-FM (2907865), VAL-SEC-T2-2+F-48DC-FM (1033786)

Implementation Advantages:

  • FM Global certification (Class I/II/III, Div 2) meets hazardous area safety standards.
  • Robust housing (IP20, -40°C~85°C) resists harsh environmental conditions.
  • Fast response time (≤25ns) protects sensitive equipment from surge damage.

3. Renewable Energy & DC Power Systems

Recommended Configuration:

  • Solar PV (380V DC): VAL-SEC-T2-2+0-380DC-FM (2907876)
  • Battery Storage (220V DC): VAL-SEC-T2-220DC-P (2907879)
  • Low-Voltage DC (48V): VAL-SEC-T2-2+F-48DC-FM (1033786)

Implementation Advantages:

  • Wide DC voltage range (48V~380V) covers most renewable energy applications.
  • Unidirectional polarity optimized for DC power flow.
  • FM certification ensures safety in outdoor and hazardous renewable energy installations.

4. Commercial Building Electrical Networks

Recommended Configuration:

  • Main Distribution Panels: VAL-SEC-T2-3C-440-FM (2909968)
  • Single-Phase Circuits: VAL-SEC-T2-1S-175-FM (2905348)
  • Neutral-Ground Protection: VAL-SEC-T2-N/PE-175-P (2905356)

Implementation Advantages:

  • 440V AC rating matches commercial building grid voltage.
  • 175kA capacity balances protection and cost-effectiveness.
  • LED status indicators enable easy maintenance for facility managers.

Selection Guide

Step 1: Determine Voltage Type & Rating

  • AC Systems: Select based on grid voltage (175V/350V/440V) and phase configuration (single/three-phase).
  • DC Systems: Match with DC power source voltage (48V/120V/220V/380V) and polarity requirements.

Step 2: Choose Pole Configuration

System Type Recommended Pole Configuration Application Example
Single-Phase AC (L+N+PE) 1S (1-pole + PE) or N/PE Office lighting, small machinery
Two-Phase AC (L1+L2+PE/N) 2S (2-pole + PE) or 2C (2-pole + N + PE) Industrial pumps, dual-phase equipment
Three-Phase AC (L1+L2+L3+N+PE) 3S (3-pole + PE) or 3C (3-pole + N + PE) Motors, power distribution panels
DC Systems (+/-, no PE) 2+0 (2-pole) Solar PV, battery storage
DC Systems (sensitive electronics) 2+F (2-pole + filter) PLCs, control circuits

Step 3: Select Functional Features

  • Hazardous Areas: Choose FM suffix models (FM Global certified).
  • Variable Frequency Systems: Select VF suffix models (inverter-compatible).
  • General Industrial Applications: Opt for P suffix models (standard performance).
  • Mixed-Load Systems: Consider dual-capacity models (e.g., 350/40kA) for versatile protection.

Step 4: Confirm Surge Capacity Requirements

  • Heavy-Duty Industrial: 350kA models (e.g., VAL-SEC-T2-3S-350-FM)
  • Light-Duty/Commercial: 175kA models (e.g., VAL-SEC-T2-1S-175-FM)
  • Sensitive Equipment: Lower Up models (≤1.2kV) for minimal voltage distortion.

Installation & Maintenance Guide

Installation Steps:

  1. Mounting: Snap the module onto a 35mm DIN rail in the power distribution panel (install as close to the power entry point as possible).
  2. Wiring: Connect conductors according to pole configuration (L/N/PE for AC; +/_ for DC) using 1.5~6mm² copper conductors.
  3. Torque: Tighten terminal screws to 0.8~1.2Nm for secure connections.
  4. Grounding: Ensure proper PE grounding (≤4Ω ground resistance) to maximize surge dissipation.
  5. Testing: Verify LED indicator (green = normal) post-installation.

Maintenance Points:

  • Status Monitoring: Regularly check LED status (red = faulty, replace immediately).
  • Replacement: Replace modules after surge events (faulty LED) or every 10 years (service life).
  • Environmental Control: Keep installation area dry and free of dust (IP20 protection).
  • Inspection: Conduct annual inspections for loose connections and damage to the housing.

VAL-SEC-T2 Series vs. Traditional Surge Protection Solutions

Comparison Dimension VAL-SEC-T2 Series Traditional Surge Protection
Surge Capacity Up to 350kA (handles heavy industrial surges) Typically ≤200kA (limited to light-duty applications)
Functional Versatility AC/DC compatibility, FM certification, VF function Limited to single voltage type/function
Hazardous Area Compliance FM certified (Div 2) for explosive environments Rarely certified for hazardous areas
Response Time ≤25ns (fast suppression for sensitive equipment) ≥50ns (slower response, higher damage risk)
Installation Flexibility 35mm DIN rail mounting (space-saving) Bulkier, fixed mounting (requires more space)
Maintenance LED status indicators (easy fault detection) No visual indicators (time-consuming troubleshooting)
Longevity -40°C~85°C operating range (10-year service life) Narrow temperature range (5-year service life)

Summary & Next Steps

The Phoenix VAL-SEC-T2 Series delivers comprehensive, reliable surge protection for AC/DC power systems across industrial, commercial, and hazardous environments. With its versatile pole configurations, wide voltage ratings, and functional variants (FM, VF, high-surge capacity), the series adapts to diverse application needs while meeting global safety standards. By selecting the appropriate model based on voltage type, pole configuration, and environmental requirements, you can effectively mitigate surge risks and ensure uninterrupted operation of critical power infrastructure.

Phoenix VAL-SEC-T2 Series: T2 Class Surge Protection Devices (SPDs) - Comprehensive Application & Selection Guide

Created on:2025-11-27 11:45

News Dynamics

NEWS