Phoenix VAL-MS-T1/T2 Series: T1/T2 Surge Protection Devices (SPD) - Comprehensive Application & Selection Guide
Product Positioning & Core Value
The Phoenix VAL-MS-T1/T2 Series represents a portfolio of T1/T2 combined surge protection devices (SPD) engineered to safeguard industrial electrical systems, photovoltaic (PV) installations, and AC/DC power networks against lightning-induced and switching surges. As dual-class (T1: lightning protection, T2: surge protection) devices, they provide comprehensive overvoltage protection for equipment such as power supplies, controllers, PV inverters, and industrial machinery.
Key Value Propositions:
- Dual-Class Protection: Integrates T1 (10/350μs) and T2 (8/20μs) surge protection in one device, eliminating the need for separate T1 and T2 SPDs.
- Wide Voltage Compatibility: Covers 48V DC to 1000V DC (PV-specific) and 175V~335V AC systems, adapting to diverse industrial and renewable energy applications.
- Flexible Pole Configurations: Available in 1+0, 1+1, 3+0, 3+1, 4+0 pole configurations to match single-phase, three-phase, and PV DC system requirements.
- Certified Reliability: Complies with IEC 61643-11, UL 1449, and FM Global standards (-FM suffix models), with PV-specific certifications for solar installations.
- Robust Design: 12.5kA maximum discharge current (I_max), IP20 protection, and -40°C~+85°C operating temperature range for harsh environments.
Product Family Classification
The VAL-MS-T1/T2 Series is categorized by application scenario (general AC/DC, PV systems) and voltage rating, with key variants distinguished by suffixes and pole configurations:
1. PV System-Specific SPDs (1000DC-PV / 600DC-PV)
- Function: Surge protection for PV system DC side (solar panels, inverters, combiner boxes).
- Key Features: High DC system voltage (600V/1000V), PV-certified, T1/T2 dual-class protection, optional voltage monitoring (2+V).
- Pole Configurations: 2+V (2 poles + voltage monitoring), single-pole (ST standard type).
- Certifications: IEC 61643-31 (PV), UL 1741, FM Global (-FM suffix).
| Model | Order No. | Core Functions | Technical Highlights | Application Scenarios |
|---|---|---|---|---|
| VAL-MS-T1/T2 1000DC-PV-ST | 2801162 | T1/T2 surge protection for 1000V DC PV systems | 1000V DC max system voltage, T1/T2 combined, ST standard type | Large-scale PV plants (utility-scale, commercial rooftop) |
| VAL-MS-T1/T2 1000DC-PV/2+V | 2801160 | 1000V DC PV SPD with 2-pole protection + voltage monitoring | 2+V (voltage sensing), 12.5kA I_max, PV-certified | PV inverter DC input protection, voltage monitoring for system safety |
| VAL-MS-T1/T2 1000DC-PV/2+V-FM | 2801161 | FM-certified 1000V DC PV SPD with voltage monitoring | FM Global certification, 2-pole + voltage monitoring | PV installations requiring FM compliance (North American markets) |
| VAL-MS-T1/T2 600DC-PV-ST | 2801165 | Standard T1/T2 SPD for 600V DC PV systems | 600V DC system voltage, compact design | Small-to-medium PV systems (residential, small commercial) |
| VAL-MS-T1/T2 600DC-PV/2+V | 2801163 | 600V DC PV SPD with 2-pole protection + voltage monitoring | 2+V configuration, PV-specific surge protection | PV combiner box DC side protection |
| VAL-MS-T1/T2 600DC-PV/2+V-FM | 2801164 | FM-certified 600V DC PV SPD with voltage monitoring | FM approval, 600V DC, voltage sensing | FM-compliant PV projects (industrial rooftop, utility-scale) |
2. AC/DC General-Purpose SPDs (335V, 175V, 48V)
- Function: Surge protection for industrial AC/DC power networks, control systems, and electrical equipment.
- Key Features: Wide voltage range (48V~335V), 12.5kA I_max, multiple pole configurations, optional FM certification (-FM suffix).
- Pole Configurations:
- 1+0: Single-phase, ungrounded (line + no neutral)
- 1+1: Single-phase, grounded (line + neutral)
- 3+0: Three-phase, ungrounded (three lines + no neutral)
- 3+1: Three-phase, grounded (three lines + neutral)
- 4+0: Three-phase, four-wire (three lines + neutral, full protection)
2.1 335V Series (AC/DC)
| Model | Order No. | Core Functions | Technical Highlights | Application Scenarios |
|---|---|---|---|---|
| VAL-MS-T1/T2 335/12.5/4+0-FM | 2800644 | 335V, 4+0 pole SPD with FM certification | 4-pole protection, FM approved, 12.5kA I_max | Three-phase four-wire AC systems, industrial machinery |
| VAL-MS-T1/T2 335/12.5/4+0 | 2800645 | Standard 335V, 4+0 pole SPD | 4-pole configuration, 335V AC/DC, T1/T2 protection | Three-phase equipment (motors, pumps, HVAC systems) |
| VAL-MS-T1/T2 335/12.5/3+1-FM | 2800183 | 335V, 3+1 pole SPD with FM certification | 3 lines + neutral protection, FM compliance | Three-phase four-wire industrial power networks |
| VAL-MS-T1/T2 335/12.5/3+1 | 2800184 | Standard 335V, 3+1 pole SPD | 3+1 pole configuration, 12.5kA discharge current | Factory power distribution systems, control panels |
| VAL-MS-T1/T2 335/12.5/3+0-FM | 2800188 | 335V, 3+0 pole SPD with FM certification | 3-pole ungrounded, FM approved | Three-phase ungrounded systems, legacy industrial equipment |
| VAL-MS-T1/T2 335/12.5/1+1-FM | 2800186 | 335V, 1+1 pole SPD with FM certification | Single-phase grounded (line + neutral), FM compliance | Commercial building electrical systems, office equipment |
| VAL-MS-T1/T2 335/12.5/1+0-FM | 2801042 | 335V, 1+0 pole SPD with FM certification | Single-phase ungrounded, 12.5kA I_max | DC power supplies, single-phase industrial controls |
| VAL-MS-T1/T2 335/12.5 ST | 2800190 | Standard 335V SPD (base model) | T1/T2 protection, 335V AC/DC, compact design | General-purpose surge protection for AC/DC circuits |
2.2 175V Series (AC/DC)
| Model | Order No. | Core Functions | Technical Highlights | Application Scenarios |
|---|---|---|---|---|
| VAL-MS-T1/T2 175/12.5/3+1-FM | 2800670 | 175V, 3+1 pole SPD with FM certification | 3+1 pole, 175V AC/DC, 12.5kA I_max | Low-voltage three-phase systems, sensitive industrial electronics |
| VAL-MS-T1/T2 175/12.5/3+0-FM | 2800672 | 175V, 3+0 pole SPD with FM certification | 3-pole ungrounded, FM approved | Low-voltage three-phase ungrounded equipment |
| VAL-MS-T1/T2 175/12.5/1+1-FM | 2800674 | 175V, 1+1 pole SPD with FM certification | Single-phase grounded, 175V, FM compliance | Low-voltage single-phase systems (sensors, actuators) |
| VAL-MS-T1/T2 175/12.5 ST | 2800676 | Standard 175V SPD | T1/T2 protection, 175V AC/DC, compact design | Low-voltage control circuits, DC power rails |
2.3 48V Series (DC)
| Model | Order No. | Core Functions | Technical Highlights | Application Scenarios |
|---|---|---|---|---|
| VAL-MS-T1/T2 48/12.5/O-FM | 2906282 | 48V DC, specialized pole SPD with FM certification | 48V DC protection, FM approved, 12.5kA I_max | 48V DC industrial control systems, battery-powered equipment |
| VAL-MS-T1/T2 48/12.5/1+0-FM | 2801240 | 48V DC, 1+0 pole SPD with FM certification | Single-phase ungrounded, 48V DC, T1/T2 protection | 48V DC power supplies, IoT devices, remote sensors |
3. Special Suffix Explanation
-FM: FM Global certified (for North American and FM-required markets).-PV: Photovoltaic system-specific (complies with IEC 61643-31, optimized for DC PV systems).-ST: Standard type (base model without additional features like voltage monitoring).2+V: 2-pole protection + voltage monitoring (for PV system status tracking).- Pole Configurations (e.g., 1+0, 3+1): Indicates number of protected lines + neutral/grounded conductor.
Technical Specifications (Universal Parameters)
| Parameter Category | Technical Indicators | Notes |
|---|---|---|
| Electrical Characteristics | ||
| Protection Class | T1/T2 (combined) | T1: 10/350μs (lightning), T2: 8/20μs (switching surges) |
| Maximum Discharge Current (I_max) | 12.5kA (8/20μs) | Consistent across all models (from "12.5" in model names) |
| Rated Voltage (U_r) | - PV: 600V DC, 1000V DC- General: 48V DC, 175V AC/DC, 335V AC/DC | Model-dependent; matches system voltage |
| Maximum System Voltage (U_sys) | - PV: 600V DC, 1000V DC- General: 48V DC, 175V AC/DC, 335V AC/DC | U_sys ≥ U_r for system compatibility |
| Pole Configurations | 1+0, 1+1, 3+0, 3+1, 4+0, 2+V | Tailored to single-phase/three-phase/PV systems |
| Voltage Protection Level (U_p) | ≤ 1.2kV (at I_max) | Ensures equipment insulation is not exceeded |
| Response Time | ≤ 25ns | Fast surge suppression to minimize damage |
| Mechanical Characteristics | ||
| Mounting Type | 35mm DIN rail (NS 35/7.5) | Compact design (width: 17.5mm~52.5mm, pole-dependent) |
| Housing Material | Polyamide PA (Flame-retardant V0 grade) | Impact-resistant, chemical-resistant |
| Protection Class | IP20 | Suitable for control cabinet and distribution box installation |
| Operating Temperature | -40°C to +85°C | Industrial-grade temperature tolerance (PV models: -40°C~+85°C) |
| Storage Temperature | -40°C to +85°C | Stable storage performance |
| Compliance & Certifications | ||
| Certifications | CE, UL 1449, FM Global (-FM), IEC 61643-11, IEC 61643-31 (-PV) | Global safety and PV-specific compliance |
| Standards | IEC 61643-1 (SPD general), IEC 61643-31 (PV), UL 1741 (PV) | Meets international surge protection standards |
| Status Indicators | LED (green = normal, red = fault) | Visual fault detection for easy maintenance |
Application Scenario Analysis
1. Photovoltaic (PV) Systems
Recommended Configuration:
- Large-Scale PV Plants (1000DC): VAL-MS-T1/T2 1000DC-PV/2+V-FM (2801161) + VAL-MS-T1/T2 1000DC-PV-ST (2801162)
- Medium-Scale PV Systems (600DC): VAL-MS-T1/T2 600DC-PV/2+V (2801163) + VAL-MS-T1/T2 600DC-PV-ST (2801165)
Advantages:
- PV-specific certification ensures compatibility with solar inverters and combiner boxes.
- 1000DC/600DC maximum system voltage matches modern PV panel string voltages.
- Voltage monitoring (2+V) enables real-time surge protection status tracking.
- FM certification meets North American market requirements for industrial PV projects.
2. Industrial AC Power Networks
Recommended Configuration:
- Three-Phase Four-Wire (335V): VAL-MS-T1/T2 335/12.5/3+1-FM (2800183)
- Three-Phase Ungrounded (335V): VAL-MS-T1/T2 335/12.5/3+0-FM (2800188)
- Single-Phase Grounded (335V): VAL-MS-T1/T2 335/12.5/1+1-FM (2800186)
Advantages:
- Multiple pole configurations adapt to diverse industrial power systems.
- 12.5kA I_max handles severe lightning and switching surges.
- FM certification ensures compliance with industrial safety standards.
- T1/T2 dual-class protection eliminates the need for separate SPDs, saving space and cost.
3. Low-Voltage DC Control Systems
Recommended Configuration:
- 48V DC Control Systems: VAL-MS-T1/T2 48/12.5/1+0-FM (2801240)
- 175V DC Equipment: VAL-MS-T1/T2 175/12.5 ST (2800676)
Advantages:
- Compact design fits in small control cabinets and IoT device enclosures.
- Fast response time (≤25ns) protects sensitive electronics (PLCs, sensors, IoT modules).
- 48V model is ideal for battery-powered and remote monitoring systems.
4. Commercial & Building Electrical Systems
Recommended Configuration:
- Single-Phase Power: VAL-MS-T1/T2 335/12.5/1+1-FM (2800186)
- Low-Voltage Lighting/Controls: VAL-MS-T1/T2 175/12.5/1+1-FM (2800674)
Advantages:
- FM certification meets commercial building safety requirements.
- 1+1 pole configuration protects line and neutral conductors, ensuring comprehensive surge protection.
- Flame-retardant housing reduces fire risk in building environments.
Selection Guide
Step 1: Identify System Type & Voltage
| System Type | Voltage Requirement | Recommended Product Series | Key Models |
|---|---|---|---|
| PV DC Systems | 600V DC | 600DC-PV Series | VAL-MS-T1/T2 600DC-PV-ST, 600DC-PV/2+V-FM |
| PV DC Systems | 1000V DC | 1000DC-PV Series | VAL-MS-T1/T2 1000DC-PV-ST, 1000DC-PV/2+V |
| Three-Phase AC | 335V AC | 335V Series (3+0/3+1/4+0) | VAL-MS-T1/T2 335/12.5/3+1-FM, 335/12.5/4+0 |
| Single-Phase AC | 335V/175V AC | 335V/175V Series (1+1) | VAL-MS-T1/T2 335/12.5/1+1-FM, 175/12.5/1+1-FM |
| DC Control Systems | 48V DC | 48V Series (1+0/O) | VAL-MS-T1/T2 48/12.5/1+0-FM |
Step 2: Select Pole Configuration
| System Wiring | Pole Configuration | Application Example |
|---|---|---|
| Single-Phase Two-Wire (U-N) | 1+1 | Commercial buildings, office equipment |
| Single-Phase Two-Wire (U-PE) | 1+0 | DC power supplies, ungrounded AC systems |
| Three-Phase Three-Wire (L1-L2-L3) | 3+0 | Three-phase ungrounded industrial machinery |
| Three-Phase Four-Wire (L1-L2-L3-N) | 3+1 | Factory power distribution, HVAC systems |
| Three-Phase Four-Wire (Full Protection) | 4+0 | Critical industrial equipment, data centers |
| PV DC (String Inverter) | 2+V | PV combiner boxes, inverter DC input |
Step 3: Confirm Certification Requirements
- North American Markets/FM Compliance: Select models with
-FMsuffix (e.g., VAL-MS-T1/T2 1000DC-PV/2+V-FM). - PV Systems: Select models with
-PVsuffix (ensures IEC 61643-31 compliance). - General Industrial Use: Standard models (without
-FM/-PV) are sufficient for CE-marked markets.
Step 4: Verify Special Features
- Voltage Monitoring: Choose
2+Vmodels for PV systems requiring real-time status tracking. - Space Constraints: All models are DIN rail-mounted; pole-dependent width (17.5mm for 1+0, 52.5mm for 4+0) ensures compatibility with control cabinets.
Installation & Maintenance Guide
Installation Steps:
- Mounting: Snap the SPD onto a 35mm DIN rail, ensuring ≥10mm spacing for heat dissipation. Install as close to the power entry point (PEN) as possible for optimal protection.
- Wiring: Connect line, neutral, and ground conductors to the corresponding terminals (marked L, N, PE). Use 1.5~4mm² copper conductors; torque terminal screws to 0.8~1.2Nm.
- Polarity Check: For DC/PV models, ensure correct polarity (positive/negative) to avoid damage. For 2+V models, connect voltage monitoring terminals to the PV inverter’s status input.
- Testing: Power on the system and verify the LED indicator (green = normal operation). Test surge protection functionality with a calibrated surge generator (optional).
Maintenance Points:
- Status Monitoring: Regularly check the LED indicator (red = fault, replace SPD immediately).
- Periodic Inspection: Conduct annual visual inspections for loose connections, damaged housing, or corrosion.
- Replacement: Replace SPDs after a major surge event (indicated by red LED) or every 10 years (service life).
- PV Systems: In dusty or harsh environments, clean the SPD housing quarterly to maintain heat dissipation.
- Documentation: Keep installation records and certification documents for compliance audits.
Product Comparison (VAL-MS-T1/T2 Series vs. Traditional SPDs)
| Comparison Dimension | Phoenix VAL-MS-T1/T2 Series | Traditional SPDs | Advantage |
|---|---|---|---|
| Protection Class | T1/T2 combined (one device) | Separate T1 and T2 SPDs | Reduces installation cost and cabinet space by 50% |
| PV Compatibility | PV-specific models (1000DC/600DC, IEC 61643-31) | Generic DC SPDs (no PV certification) | Ensures reliable protection for high-voltage PV strings |
| Pole Flexibility | 1+0 to 4+0 + 2+V configurations | Limited pole options (1+1, 3+1 only) | Adapts to diverse system wiring (single-phase/three-phase/PV) |
| Certification | CE, UL, FM, PV-specific | CE/UL only | Complies with global market requirements (e.g., FM for North America) |
| Response Time | ≤25ns | ≥50ns | Faster surge suppression protects sensitive electronics |
| Status Monitoring | LED indicator + 2+V voltage monitoring (PV) | Basic LED only | Enables remote status tracking for PV systems |
Summary & Next Steps
The Phoenix VAL-MS-T1/T2 Series delivers comprehensive, cost-effective surge protection for industrial, PV, and commercial electrical systems. With T1/T2 dual-class protection, wide voltage compatibility, flexible pole configurations, and global certifications, these SPDs safeguard equipment against lightning and switching surges while simplifying installation and maintenance.