Phoenix MCR Series: Modular Signal Conditioners & Transducers - Comprehensive Application & Selection Guide

Product Positioning & Core Value

The Phoenix MCR Series represents a versatile family of modular signal conditioning and conversion solutions designed to interface industrial sensors, actuators, and control systems. These DIN rail-mounted modules provide electrical isolation, signal conversion, amplification, and protection between different parts of automation systems, ensuring reliable data transmission while safeguarding sensitive equipment from voltage spikes, ground loops, and electromagnetic interference.

Key Value Propositions:

  • Universal Compatibility: Works with virtually all industrial signal types (voltage, current, temperature, frequency)
  • 3-Way Isolation: Protects measurement circuits from supply voltage fluctuations and ground loops
  • Signal Flexibility: Converts between standard industrial signals (0-10V, 4-20mA, etc.)
  • Space Efficiency: Compact design (12.5-22.5mm width) saves cabinet space
  • Industrial Robustness: Operates in extreme temperatures (-40°C to +70°C) with IP20 protection
  • Easy Configuration: Many models feature DIP switch programming without additional software

Product Family Classification

1. MCR-VDC Series: DC Voltage Transducers

Function: Convert DC voltages from 0 to ±660V to standard output signals (0-10V, 4-20mA) with electrical isolation.

Model Order No. Core Functions Technical Highlights Applications
MCR-VDC-UI-B-DC 2811116 DC voltage measurement with bipolar output Input: -550V to +550V, Output: ±10V/±20mA, 1.5kV isolation DC power supplies, battery monitoring, solar inverters Phoenix Contact USA

2. MCR-VAC Series: AC Voltage Transducers

Function: Convert AC voltages from 0 to 440V to standard output signals.

Model Order No. Core Functions Technical Highlights Applications
MCR-VAC-UI-O-DC 2811103 AC voltage measurement with unipolar output Input: 0-370V AC, Output: 0-10V/4-20mA, 3.3kV isolation AC motor control, power distribution monitoring

3. MCR-T Series: Temperature Transducers

Function: Convert thermocouple or RTD sensor signals to standard industrial signals.

Model Order No. Core Functions Technical Highlights Applications
MCR-T-UI-NC 2814100 General-purpose temperature measurement Supports RTD (Pt100) and thermocouples (J, K, T), Output: 0-10V/4-20mA Industrial ovens, HVAC systems
MCR-T-UI-E-NC 2814126 Enhanced temperature measurement with error monitoring Configurable input range (-200°C to 1372°C), transistor alarm output Process control, medical equipment

4. MCR-TE Series: Thermocouple Transducers

Function: Optimized for thermocouple sensors (Type J/K).

Model Order No. Core Functions Technical Highlights Applications
MCR-TE-J-K-U-NC 2810573 J/K-type thermocouple measurement Input: 0-1200°C, Output: 0-10V, DIP switch configurable Furnaces, kilns, heat treatment
MCR-TE-JK-I-E 2810528 J/K-type thermocouple measurement with current output Input: 0-1200°C, Output: 4-20mA, isolation protection Phoenix Contact USA Remote monitoring, PLC interfaces

5. MCR-SWS Series: Limit Value Switches

Function: Convert analog signals to digital outputs at adjustable threshold levels.

Model Order No. Core Functions Technical Highlights Applications
MCR-SWS-U 2766465 Voltage input threshold switch Input: 0-10V, Relay output, adjustable hysteresis Pump control, level monitoring
MCR-SWS-I 2766478 Current input threshold switch Input: 0-20mA, PNP transistor output, 2A switching capacity Motor protection, flow monitoring

6. MCR-SPP Series: Signal Splitters

Function: Duplicate input signals to multiple outputs.

Model Order No. Core Functions Technical Highlights Applications
MCR-SPP-I-4 2810049 4-channel current signal splitter Input: 4-20mA, Outputs: 4 isolated 4-20mA signals PLC redundancy, multi-device monitoring

7. MCR-SL Series: Signal Conditioners

Function: General-purpose signal conditioning with various input/output combinations.

Model Order No. Core Functions Technical Highlights Applications
MCR-SL-S-400-U 2813473 Universal signal conditioner (400V) Configurable for voltage/current inputs/outputs General automation, panel building
MCR-SL-S-200-I-LP 2813499 Current signal conditioner (200V) Low-power design, 4-20mA input/output Sensor signal conversion
MCR-SL-S-16-SP-24 2864464 16-channel signal splitter (24V) Space-saving, 16 isolated outputs Multi-point monitoring systems
MCR-SL-S-1/5-I-DCI-230 2814825 Current-to-current converter (1:5 ratio) 230V isolation, for precision measurement Test benches, calibration systems

8. MCR-TTL-RS232-E: Communication Adapter

Function: Connects MCR modules to PC/PLC for programming and monitoring.

Model Order No. Core Functions Technical Highlights Applications
MCR-TTL-RS232-E 2814388 Programming interface cable 1.2m length, converts TTL to RS232 Configuration of MCR-T/MCR-TE series modules

Technical Specifications (Universal Parameters)

Parameter Category Technical Indicators Notes
Electrical Characteristics    
Supply Voltage 18-30V DC (nominal 24V DC) All series except MCR-VAC (AC supply)
Isolation Voltage 1.5kV-3.3kV (input/output/supply) Protects against voltage surges Phoenix Contact USA
Input Signals Voltage: 0-10V/±10V, 0-100V/±100V, etc.Current: 0-20mA/4-20mATemperature: Thermocouples (J/K/T/E), RTD (Pt100) Model-dependent
Output Signals Voltage: 0-5V/0-10V/±10VCurrent: 0-20mA/4-20mASwitching: Relay/PNP transistor (limit switches) Model-dependent
Mechanical Characteristics    
Mounting 35mm DIN rail (NS 35/7.5) All series Phoenix Contact USA
Housing Flame-retardant polyamide (PA), green (RAL 6021) IP20 protection, impact-resistant Phoenix Contact USA
Dimensions Width: 12.5-22.5mm (varies by model)Height: 99mmDepth: 114.5mm Compact design for control cabinets Phoenix Contact USA
Connection Screw terminals (M3) or push-in (some models) Accepts 0.2-2.5mm² conductors Phoenix Contact USA
Environmental Parameters    
Operating Temp. -25°C to +60°C (standard)-40°C to +70°C (extended models) Industrial-grade reliability Phoenix Contact USA
Storage Temp. -40°C to +85°C (non-condensing) Long-term stability Phoenix Contact USA
Certifications    
Compliance CE, UL/cULus, EMC Directive Global industrial standards Phoenix Contact USA
Standards EN 61000-6-2 (immunity), EN 61000-6-4 (emission) EMC performance Phoenix Contact USA

Application Scenario Analysis

1. Industrial Automation Systems

Recommended Configuration:

  • Voltage monitoring: MCR-VDC-UI-B-DC (2811116)
  • Temperature control: MCR-T-UI-E-NC (2814126)
  • Signal distribution: MCR-SL-S-400-U (2813473)

Advantages:

  • 3-way isolation prevents ground loops and voltage spikes
  • Converts non-standard signals to PLC-compatible outputs
  • Compact design saves 30% cabinet space compared to traditional solutions

2. HVAC & Building Management

Recommended Configuration:

  • Temperature sensing: MCR-TE-J-K-U-NC (2810573) with thermocouples
  • Humidity/pressure signal conditioning: MCR-SL-S-200-I-LP (2813499)

Advantages:

  • Precise temperature measurement (±0.1% accuracy)
  • Low-power design reduces energy consumption
  • Reliable performance in harsh environmental conditions

3. Renewable Energy Systems

Recommended Configuration:

  • Solar inverter monitoring: MCR-VDC-UI-B-DC (2811116)
  • Battery management: MCR-SL-S-1/5-I-DCI-230 (2814825)

Advantages:

  • Measures wide voltage ranges (up to ±660V DC)
  • Isolation protects sensitive electronics from grid fluctuations
  • High accuracy (≤1% error) ensures reliable energy management

4. Process Control & Monitoring

Recommended Configuration:

  • Multi-point monitoring: MCR-SL-S-16-SP-24 (2864464)
  • Alarm functions: MCR-SWS-U (2766465)

Advantages:

  • 16-channel design monitors multiple parameters simultaneously
  • Adjustable hysteresis prevents false alarms
  • Relay outputs directly control alarms or shutdown systems

Selection Guide

Step 1: Identify Signal Type & Range

Signal Type Recommended Series Model Selection Guide
DC Voltage (0-660V) MCR-VDC Choose based on input range (e.g., ±550V for MCR-VDC-UI-B-DC) Phoenix Contact USA
AC Voltage (0-440V) MCR-VAC Select based on maximum expected voltage
Temperature (Thermocouple) MCR-TE Specify thermocouple type (J/K) and temperature range
Temperature (RTD) MCR-T Choose models supporting 2/3/4-wire Pt100 sensors
Current (4-20mA) MCR-SL (I variants) Select for signal conversion or splitting
Frequency/PWM MCR-F (not listed) For converting rotational speed to analog signals

Step 2: Determine Output Requirements

  • Analog Output: Choose voltage (0-10V) or current (4-20mA) based on receiving device
  • Digital Output: Select MCR-SWS series for relay or transistor outputs at set thresholds
  • Multiple Outputs: Use MCR-SPP or MCR-SL-SP series for signal duplication

Step 3: Consider Environmental & Safety Needs

  • Isolation Level: Standard 1.5kV for general use; 3.3kV for high-noise environments
  • Temperature Range: Standard (-25°C to +60°C) or extended (-40°C to +70°C) for extreme conditions
  • Mounting: All models use 35mm DIN rail; check width (12.5-22.5mm) for space constraints

Step 4: Select Termination Type

  • Screw Terminals (SC): Secure connection for vibration-prone environments
  • Push-In Terminals (PI): Quick installation without tools (some models only)

Installation & Maintenance Guide

Installation Steps:

  1. Mounting: Snap modules onto 35mm DIN rail, ensuring ≥5mm spacing between units for heat dissipation

  2. Wiring:

    • Screw Terminals: Strip conductors to 8mm, insert into terminals, tighten to 0.5-0.8Nm
    • Push-In Terminals: Insert stripped conductor until it clicks (no tool needed)
  3. Signal Connection:

    • Connect sensors to input terminals
    • Connect output to receiving device (PLC, indicator, etc.)
    • Connect power supply (18-30V DC)
  4. Configuration:

    • For DIP-switch models: Set input/output ranges and functions per datasheet
    • For programmable models: Use MCR-TTL-RS232-E (2814388) to connect to PC and configure via software

Maintenance Points:

  • Visual Inspection: Check LEDs (power, signal, fault) during regular maintenance
  • Cleaning: Wipe dust from housing quarterly (non-abrasive cloth)
  • Terminal Retightening: For screw terminals, verify tightness every 6 months
  • Module Replacement:
    • Replace immediately if fault LED lights
    • Service life: 10 years under normal conditions
    • When replacing, ensure same model or compatible replacement

Product Comparison (MCR Series vs. Traditional Solutions)

Comparison MCR Series Traditional Solutions Advantage
Integration Single module for signal conditioning + isolation Separate conditioner + isolator 50% space savings, reduced wiring Phoenix Contact USA
Flexibility Configurable for multiple signal types/ranges Fixed-function devices One part number covers multiple applications
Accuracy ≤0.1% (temperature), ≤1% (voltage/current) 1-5% Higher precision for critical measurements
Installation Time 5-minute DIN rail mounting + wiring Complex assembly 60% faster installation Phoenix Contact USA
Diagnostics LED indicators, fault monitoring Limited status indication Quicker troubleshooting
Cost Higher initial cost, lower total cost of ownership Lower initial cost, higher maintenance 3-year ROI due to reduced downtime Phoenix Contact USA

Summary & Next Steps

The Phoenix MCR Series provides a comprehensive, modular approach to industrial signal conditioning, offering universal compatibility, superior isolation, and flexible configuration for automation systems. By standardizing on these versatile modules, engineers can simplify system design, reduce inventory, and improve reliability across diverse applications.

Phoenix MCR Series: Modular Signal Conditioners & Transducers - Comprehensive Application & Selection Guide

Created on:2025-12-02 10:46

News Dynamics

NEWS