Phoenix VAL-MS Series Surge Protection Device (SPD) Selection Guide: Precise Matching of Part Number, Model, and Application
Opening: Reliable Overvoltage Protection for Industrial Systems – One-Stop Part Number & Model Reference
In industrial power systems, photovoltaic (PV) installations, and building electrical networks, surge voltages (caused by lightning, grid fluctuations, or equipment switching) pose severe threats to sensitive electronics and critical equipment. As a core product line of Phoenix’s surge protection portfolio, the VAL-MS series offers multi-level protection, wide voltage compatibility, and industry-specific customization (AC/DC PV scenarios). This guide integrates part number-model correspondence, core protection features, and scenario adaptation to provide clear guidance for technical selection and procurement, helping to quickly lock in suitable surge protection solutions for different power systems.
I. Core Advantages: Why Choose the Phoenix VAL-MS Series?
- Comprehensive protection levels: Covers Type 2 (T2) secondary protection and Type 1+2 (T1/T2) combined protection, adapting to different surge risk levels.
- Dual-system compatibility: Separated product lines for AC (VAL-MS-EE) and DC PV (VAL-MS-CN) systems, matching voltage ranges from 320V to 1000DC.
- Flexible pole configurations: Supports 3+1 (3-phase + PE), 3+0 (3-phase no PE), 1+1 (1-phase + PE), 1+0 (1-phase no PE), and 2+V (PV bipolar + ground) pole designs, fitting various system topologies.
- Industrial-grade reliability: Operating temperature range of -40°C to +85°C, IP20 protection class, corrosion-resistant materials, suitable for harsh outdoor/indoor environments.
- Compliant with global certifications: FM certification (FM suffix models) for North American markets, IEC 61643-12 compliance for PV applications, meeting international safety standards.
II. Complete Product Series Selection Table (Part Number + Model + Core Information)
1. VAL-MS-EE Series: AC Surge Protection Devices
Designed for AC power systems (industrial plants, data centers, building electrical networks), supporting single-phase/three-phase configurations.
| Part Number | Complete Model | Core Functions | Key Specifications | Application Scenario |
|---|---|---|---|---|
| 2910569 | VAL-MS-EE-T2-385-P | Type 2 secondary protection, 3-phase (3+0 pole), 385V AC, pluggable design | T2, 3+0, 385V AC, P (pluggable) | Industrial 3-phase power systems, easy maintenance and replacement |
| 2910558 | VAL-MS-EE-T2-3+1-385-FM | Type 2 secondary protection, 3-phase + PE (3+1 pole), 385V AC, FM certified | T2, 3+1, 385V AC, FM | North American market 3-phase systems (e.g., factories, commercial buildings) |
| 2910559 | VAL-MS-EE-T2-3+1-385 | Type 2 secondary protection, 3-phase + PE (3+1 pole), 385V AC | T2, 3+1, 385V AC | Global 3-phase power distribution networks, general industrial scenarios |
| 2910574 | VAL-MS-EE-T2-3+1-320-FM | Type 2 secondary protection, 3-phase + PE (3+1 pole), 320V AC, FM certified | T2, 3+1, 320V AC, FM | Low-voltage 3-phase systems in North American data centers, precision equipment protection |
| 2910563 | VAL-MS-EE-T2-3+0-385 | Type 2 secondary protection, 3-phase no PE (3+0 pole), 385V AC | T2, 3+0, 385V AC | 3-phase systems with independent PE wiring, industrial control cabinets |
| 1233861 | VAL-MS-EE-T2-2+0-330DC-FM | Type 2 secondary protection, 2-pole (2+0), 330V DC, FM certified | T2, 2+0, 330V DC, FM | DC power systems (e.g., battery storage), North American compliance requirements |
| 2910561 | VAL-MS-EE-T2-1+1-385-FM | Type 2 secondary protection, 1-phase + PE (1+1 pole), 385V AC, FM certified | T2, 1+1, 385V AC, FM | North American single-phase systems (e.g., office buildings, small workshops) |
| 2910562 | VAL-MS-EE-T2-1+1-385 | Type 2 secondary protection, 1-phase + PE (1+1 pole), 385V AC | T2, 1+1, 385V AC | Global single-phase power systems, residential/commercial electrical networks |
| 2910565 | VAL-MS-EE-T2-1+0-385 | Type 2 secondary protection, 1-phase no PE (1+0 pole), 385V AC | T2, 1+0, 385V AC | Single-phase systems with integrated PE, small-scale automation equipment |
| 2910550 | VAL-MS-EE-T1/T2-3+1-335-FM | Type 1+2 combined protection, 3-phase + PE (3+1 pole), 335V AC, FM certified | T1/T2, 3+1, 335V AC, FM | High-surge-risk 3-phase systems (e.g., outdoor installations), lightning-prone areas |
| 2910551 | VAL-MS-EE-T1/T2-3+1-335 | Type 1+2 combined protection, 3-phase + PE (3+1 pole), 335V AC | T1/T2, 3+1, 335V AC | Global high-risk 3-phase systems, industrial plants in thunderstorm regions |
| 2910555 | VAL-MS-EE-T1/T2-3+0-335 | Type 1+2 combined protection, 3-phase no PE (3+0 pole), 335V AC | T1/T2, 3+0, 335V AC | High-risk 3-phase systems with independent PE, outdoor power distribution |
| 2910552 | VAL-MS-EE-T1/T2-1+1-335-FM | Type 1+2 combined protection, 1-phase + PE (1+1 pole), 335V AC, FM certified | T1/T2, 1+1, 335V AC, FM | North American high-risk single-phase systems (e.g., rooftop equipment) |
| 2910553 | VAL-MS-EE-T1/T2-1+1-335 | Type 1+2 combined protection, 1-phase + PE (1+1 pole), 335V AC | T1/T2, 1+1, 335V AC | Global high-risk single-phase systems, outdoor small-scale power networks |
2. VAL-MS-CN Series: DC PV-Specific Surge Protection Devices
Customized for photovoltaic systems (PV arrays, inverters), supporting high DC voltage (1000DC) and bipolar protection.
| Part Number | Complete Model | Core Functions | Key Specifications | Application Scenario |
|---|---|---|---|---|
| 2801309 | VAL-MS-CN 1000DC-PV-ST | DC surge protection, 1000V DC, PV-specific, standard terminal | 1000DC, PV, ST (standard terminal) | PV system DC side (array to inverter), single-pole protection |
| 2801311 | VAL-MS-CN 1000DC-PV/2+V-FM | DC surge protection, 1000V DC, PV bipolar + ground (2+V), FM certified | 1000DC, PV, 2+V, FM | North American PV systems, bipolar DC protection (positive/negative + ground) |
| 2801310 | VAL-MS-CN 1000DC-PV/2+V | DC surge protection, 1000V DC, PV bipolar + ground (2+V) | 1000DC, PV, 2+V | Global large-scale PV plants, DC side surge protection for inverters |
III. 3-Step Quick Selection Technique (Easy for Beginners)
Step 1: Determine System Type & Voltage
- AC system: Select VAL-MS-EE series; confirm rated voltage (320V/335V/385V AC) ≥ system voltage (e.g., 380V AC system → 385V AC models).
- DC PV system: Select VAL-MS-CN series; must match PV system DC voltage (1000DC for mainstream high-voltage PV arrays).
- Special DC systems: For 330V DC (e.g., battery storage), select VAL-MS-EE-T2-2+0-330DC-FM.
Step 2: Select Protection Level & Pole Configuration
- Protection level:
- High surge risk (outdoor, lightning-prone areas) → Type 1+2 (T1/T2) combined protection (e.g., 2910551).
- General risk (indoor, grid fluctuations) → Type 2 (T2) secondary protection (e.g., 2910559).
- Pole configuration:
- 3-phase AC system → 3+1 (with PE) or 3+0 (without PE) (e.g., 3-phase power distribution → 2910559).
- 1-phase AC system → 1+1 (with PE) or 1+0 (without PE) (e.g., commercial buildings → 2910562).
- PV DC system → 2+V (bipolar + ground) (e.g., PV arrays → 2801310).
Step 3: Confirm Certification & Installation Requirements
- Regional certification: North American market → FM-certified models (with "FM" suffix, e.g., 2910558).
- Installation type: Need easy replacement → Pluggable models (with "P" suffix, e.g., 2910569).
- Terminal type: Standard terminals (ST) for PV systems → 2801309.
IV. Recommended Industry-Scenario Combinations (Ready-to-Use)
| Industry | Typical Scenario | Recommended Model Combination |
|---|---|---|
| Industrial Manufacturing | 3-phase power distribution (high surge risk) | 2910551 (VAL-MS-EE-T1/T2-3+1-335) + 2910569 (VAL-MS-EE-T2-385-P) |
| Data Center (North America) | 1-phase precision equipment protection | 2910561 (VAL-MS-EE-T2-1+1-385-FM) + 1233861 (VAL-MS-EE-T2-2+0-330DC-FM) |
| Large-Scale PV Plant | DC side (array to inverter) protection | 2801310 (VAL-MS-CN 1000DC-PV/2+V) + 2910559 (VAL-MS-EE-T2-3+1-385) |
| Commercial Building | 3-phase power + single-phase lighting | 2910559 (VAL-MS-EE-T2-3+1-385) + 2910562 (VAL-MS-EE-T2-1+1-385) |
| Outdoor Automation | High-risk 1-phase equipment (lightning-prone) | 2910553 (VAL-MS-EE-T1/T2-1+1-335) + 2910565 (VAL-MS-EE-T2-1+0-385) |
V. Selection Pitfall Avoidance Guide (Common Mistakes to Note)
- Voltage mismatch: Rated voltage of SPD must be ≥ system voltage (e.g., 380V AC system cannot use 320V AC models), otherwise protection fails.
- Incorrect pole configuration: 3-phase systems missing PE → Use 3+1 pole models (not 3+0) to ensure surge discharge to ground.
- Underestimating protection level: Outdoor or lightning-prone areas must use T1/T2 combined protection (not T2 alone) to block direct lightning surges.
- Ignoring PV bipolar protection: PV DC systems require 2+V pole models (not single-pole) to protect both positive and negative terminals.
- Missing regional certification: North American market installations must use FM-certified models (with "FM" suffix) to meet local safety standards.
- Overlooking installation type: Hard-to-maintain areas (e.g., high-altitude PV arrays) should select pluggable models (with "P" suffix) for easy replacement.
Conclusion: Select the Right SPD for Comprehensive System Protection
The Phoenix VAL-MS series provides targeted surge protection solutions for AC industrial systems and DC PV installations with its multi-level protection, flexible configurations, and global certification compliance.