In industrial automation and process control systems, accurate signal conditioning, conversion, and isolation are critical for reliable data transmission and control execution. The Phoenix MCR series offers a comprehensive portfolio of modular solutions, covering temperature measurement, signal conversion, power supply, and explosion-proof applications (EX series). With high precision, flexible configuration, and industrial-grade durability, the MCR series is widely used in process manufacturing, energy, and intelligent production scenarios. This guide integrates part number-model correspondence, core technical parameters, and scenario-specific recommendations to simplify technical selection and procurement, helping you quickly lock in optimal signal processing solutions.


I. Core Advantages: Why Choose the Phoenix MCR Series?

  • Full signal compatibility: Covers temperature (PT100), current (4-20mA), voltage (0-10V), frequency, and digital signals, meeting multi-type signal processing needs.
  • Flexible installation & configuration: Supports Push-in (SP) quick connection, low-profile (LP) design, and modular DIN rail mounting, adapting to space-constrained control cabinets.
  • High precision & stability: Signal transmission accuracy up to ±0.1%, anti-electromagnetic interference (EMI), suitable for harsh industrial environments (-40°C to +70°C).
  • Specialized functional designs: Includes explosion-proof (EX) models for hazardous areas, dual-output power supplies, and USB-configurable modules, enhancing system adaptability.
  • Easy integration: Compatible with Phoenix’s industrial ecosystem, supporting seamless connection with PLCs, sensors, and actuators.

II. Complete Product Series Selection Table (Part Number + Model + Core Information)

1. MCR-SL Series: Signal Conditioning & Isolation Modules (Most Widely Used)

Designed for signal isolation, conversion, and conditioning, supporting temperature, current, voltage, and frequency signals.

Part Number Complete Model Core Functions Key Specifications Application Scenario
2306427 MCR-SL-PT100-SP/SO139 PT100 temperature signal isolation, Push-in connection, SO139 terminal Input: PT100; Output: Isolated signal; Connection: Push-in (SP) Rapid-installation temperature measurement (e.g., pipeline temperature monitoring)
2814948 MCR-SL-PT100-SP PT100 temperature signal conditioning, Push-in connection Input: PT100; Connection: Push-in (SP) General industrial temperature sensing, quick wiring projects
2864558 MCR-SL-PT100-LP-I PT100 temperature-to-current conversion, low-profile (LP) design Input: PT100; Output: 4-20mA; Installation: Low-profile Space-constrained control cabinets, compact equipment temperature monitoring
2814883 MCR-SL-PT100-I-DC-24 PT100 temperature-to-current conversion, 24V DC powered Input: PT100; Output: 4-20mA; Power: 24DC 24V DC automation systems (e.g., PLC-linked temperature transmission)
2814359 MCR-SLP-1-5-UI-0 1-5V voltage signal isolation & conversion Input: 1-5V; Output: Isolated voltage; Protection: 4KV surge Voltage signal transmission in high-interference environments (e.g., sensor signal conditioning)
2864516 MCR-SL-HT-PT 100-I High-temperature PT100 signal-to-current conversion Input: PT100 (high-temperature range); Output: 4-20mA High-temperature process monitoring (e.g., reaction 釜 temperature measurement)
2864011 MCR-SL-D-U-I Current-to-voltage signal conversion (dual-channel) Input: 4-20mA; Output: 0-10V; Channels: 2 Dual-channel signal conversion (e.g., flow/pressure signal integration)
2710314 MCR-SL-D-SPA-UI Dual-channel signal isolation with Push-in connection Input: Universal (current/voltage); Output: Isolated signal; Connection: SP Batch-installation dual-channel signal processing (e.g., production line multi-point monitoring)
2810081 MCR-SL-D-RA Dual-channel signal conversion with relay output Input: Universal; Output: Relay contact; Channels: 2 Signal-triggered switching (e.g., temperature/pressure limit control)
2864024 MCR-SL-D-FIT Dual-channel signal conditioning (customizable fit) Input/Output: Configurable; Channels: 2 Customized signal processing (e.g., non-standard sensor signal adaptation)
2814841 MCR-SL-1CLP-I-I-00-4KV Single-channel current isolation, 4KV surge protection Input/Output: 4-20mA; Protection: 4KV; Channels: 1 High-voltage interference environments (e.g., power plant signal transmission)

2. MCR-SGA/R Series: Signal Distribution & Conversion Modules

Specialized in signal distribution (SGA) and current/voltage conversion (R), suitable for multi-device signal sharing.

Part Number Complete Model Core Functions Key Specifications Application Scenario
5604058 MCR-SGA-4/6-DC 4-input 6-output signal distributor, DC-powered Input: Universal; Output: 6-way isolated signal; Power: DC Multi-device signal sharing (e.g., one sensor signal to 6 PLC inputs)
2769637 MCR-R-U-V Voltage-to-voltage signal conversion (0-10V → 0-10V) Input: 0-10V; Output: 0-10V; Isolation: Yes Voltage signal amplification/conditioning (e.g., weak signal enhancement)
2769653 MCR-R-I-4-V-DC 4-20mA current-to-0-10V voltage conversion, DC-powered Input: 4-20mA; Output: 0-10V; Power: 24DC PLC analog input adaptation (e.g., current sensor to voltage signal)
2769624 MCR-R-I-4-V 4-20mA current-to-0-10V voltage conversion (universal power) Input: 4-20mA; Output: 0-10V; Power: AC/DC universal Mixed-power system signal conversion (e.g., traditional relay cabinet upgrades)

3. MCR-PT100 Series: Dedicated Temperature Transmitter Modules

Optimized for PT100 thermal resistance signals, providing high-precision temperature-to-current/voltage conversion.

Part Number Complete Model Core Functions Key Specifications Application Scenario
2810418 MCR-PT100-U-NC PT100 temperature-to-voltage conversion, non-contact (NC) Input: PT100; Output: 0-10V; Design: Non-contact High-reliability temperature monitoring (e.g., cleanroom equipment)
2810311 MCR-PT100-U-DC PT100 temperature-to-voltage conversion, 24V DC powered Input: PT100; Output: 0-10V; Power: 24DC DC-powered automation systems (e.g., battery-operated monitoring devices)
2810340 MCR-PT100-U PT100 temperature-to-voltage conversion (universal power) Input: PT100; Output: 0-10V; Power: AC/DC General temperature-to-voltage transmission (e.g., HVAC system temperature monitoring)
2810447 MCR-PT100-I-DC-NC PT100 temperature-to-current conversion, DC-powered, non-contact Input: PT100; Output: 4-20mA; Power: 24DC; NC High-precision industrial temperature sensing (e.g., pharmaceutical reactor temperature control)
2810353 MCR-PT100-I PT100 temperature-to-current conversion (universal power) Input: PT100; Output: 4-20mA; Power: AC/DC Standard temperature-to-current transmission (e.g., pipeline pressure/temperature integration)
2810337 MCR-PT100/I/DC PT100 temperature-to-current conversion, DC-powered (compact) Input: PT100; Output: 4-20mA; Power: 24DC Compact control cabinets (e.g., small-scale equipment temperature monitoring)

4. MCR-PS/PAC Series: Power Supply & Auxiliary Modules

Provides stable power supply (PS) and USB-configurable auxiliary functions (PAC) for system integration.

Part Number Complete Model Core Functions Key Specifications Application Scenario
2811925 MCR-PSP-DC DC power supply module (protected) Output: Stable DC voltage; Protection: Overload/short-circuit Sensor/module power supply (e.g., 24V DC sensor power distribution)
2811912 MCR-PSP Universal power supply module (protected) Output: AC/DC configurable; Protection: Overload/short-circuit Mixed-power system power supply (e.g., control cabinet auxiliary power)
2766685 MCR-PS-24DC-10DC 24V DC input → 10V DC output power converter Input: 24DC; Output: 10DC; Power: 200mA Low-voltage sensor power supply (e.g., weak signal sensor dedicated power)
2781877 MCR-PS-24DC/2X24DC 24V DC input → dual 24V DC output power supply Input: 24DC; Output: 2×24DC; Power: 200mA×2 Dual-device power supply (e.g., two sensors/actuators parallel power)
2766821 MCR-PS-24DC/24DC/200 24V DC input → 24V DC output (200mA) power supply Input: 24DC; Output: 24DC; Current: 200mA Low-current module power supply (e.g., signal conditioning module power)
2309000 MCR-PAC-T-USB USB-configurable auxiliary module Interface: USB; Function: Parameter configuration Custom signal processing (e.g., module parameter programming via PC)

5. MCR-F/FL Series: Frequency & Explosion-Proof Temperature Modules

Covers frequency signal conditioning (F) and explosion-proof temperature processing (FL-EX), suitable for special scenarios.

Part Number Complete Model Core Functions Key Specifications Application Scenario
2814605 MCR-F-UI-DC Frequency-to-voltage/current conversion, DC-powered Input: Frequency; Output: 0-10V/4-20mA; Power: 24DC Speed/flow signal conversion (e.g., pump/motor speed monitoring)
2864587 MCR-FL-TS-LP-I-EX Explosion-proof (EX) temperature signal conditioning, low-profile Input: Thermocouple/PT100; Output: 4-20mA; Certification: Ex Hazardous area temperature monitoring (e.g., petrochemical plant pipeline temperature)
2864574 MCR-FL-T-LP-I-EX Explosion-proof temperature-to-current conversion, low-profile Input: Thermocouple; Output: 4-20mA; Certification: Ex; LP Explosion-proof area compact temperature sensing (e.g., hazardous zone equipment temperature)
2864561 MCR-FL-T-LP-I Temperature-to-current conversion, low-profile (non-explosion-proof) Input: Thermocouple; Output: 4-20mA; LP General industrial low-profile temperature monitoring (e.g., compact reactor temperature)
2864545 MCR-FL-HT-TS-I-EX Explosion-proof high-temperature signal conditioning Input: High-temperature thermocouple/PT100; Output: 4-20mA; Ex Explosion-proof high-temperature scenarios (e.g., refinery furnace temperature)
2864532 MCR-FL-HT-T-I-EX Explosion-proof high-temperature temperature-to-current conversion Input: High-temperature thermocouple; Output: 4-20mA; Ex Hazardous area high-temperature monitoring (e.g., chemical reaction temperature control)
2864529 MCR-FL-HT-T-I High-temperature temperature-to-current conversion (non-explosion-proof) Input: High-temperature thermocouple; Output: 4-20mA General high-temperature process monitoring (e.g., steel mill equipment temperature)

III. 3-Step Quick Selection Technique (Easy for Beginners)

Step 1: Determine Core Function & Signal Type

  • Temperature measurement (PT100/thermocouple):
    • General temperature → MCR-PT100 series (e.g., 2810353);
    • High-temperature → MCR-SL-HT/FL-HT series (e.g., 2864516, 2864529);
    • Explosion-proof area → MCR-FL-EX series (e.g., 2864574).
  • Current/voltage conversion: MCR-R/SL series (e.g., 2769653, 2864011).
  • Signal distribution: MCR-SGA series (e.g., 5604058).
  • Power supply: MCR-PS series (e.g., 2781877).
  • Frequency signal: MCR-F series (e.g., 2814605).

Step 2: Confirm Input/Output & Power Requirements

  • Input signal: PT100 → select "PT100" models; thermocouple → "T/TS" models; current → "I" models; voltage → "U" models.
  • Output signal: Need 4-20mA → "I" suffix; 0-10V → "U" suffix; relay → "RA" suffix.
  • Power supply: 24V DC (most automation systems) → "DC-24" models; universal power → no voltage suffix.

Step 3: Select Special Requirements

  • Installation: Quick wiring → Push-in (SP suffix, e.g., 2814948); space-constrained → low-profile (LP suffix, e.g., 2864558).
  • Explosion-proof: Hazardous areas (Zone 0/1/2) → "EX" suffix models (e.g., 2864574).
  • Protection: High-interference environments → 4KV surge protection (e.g., 2814841).
  • Configuration: Custom parameters → USB-configurable (MCR-PAC-T-USB, 2309000).

IV. Recommended Industry-Scenario Combinations (Ready-to-Use)

Industry Typical Scenario Recommended Model Combination
Petrochemical (Explosion-Proof) Hazardous area high-temperature monitoring 2864532 (MCR-FL-HT-T-I-EX) + 2769653 (MCR-R-I-4-V-DC)
Industrial Automation PT100 temperature → PLC voltage input 2810353 (MCR-PT100-I) + 5604058 (MCR-SGA-4/6-DC)
Process Control High-interference current signal transmission 2814841 (MCR-SL-1CLP-I-I-00-4KV) + 2781877 (MCR-PS-24DC/2X24DC)
Compact Control Cabinets Low-profile temperature + power supply 2864558 (MCR-SL-PT100-LP-I) + 2766821 (MCR-PS-24DC/24DC/200)
HVAC Systems Temperature-to-voltage signal conversion 2810340 (MCR-PT100-U) + 2769637 (MCR-R-U-V)

V. Selection Pitfall Avoidance Guide (Common Mistakes to Note)

  1. Explosion-proof misuse: Non-EX models used in hazardous areas → Only "EX" suffix models (2864574) are compliant with explosion-proof standards.
  2. Signal mismatch: PT100 input using thermocouple models → Confirm "PT100" in model (e.g., 2814948) for temperature compatibility.
  3. Power supply error: 24DC system using AC-powered models → Check "DC" suffix (e.g., 2814883) to avoid module burnout.
  4. Space neglect: Compact cabinets using standard-profile models → Select LP suffix (2864558) for low-profile installation.
  5. Interference ignoring: High-voltage environments using unprotected models → Choose 4KV surge protection (2814841) to prevent signal distortion.
  6. Output type error: PLC requiring voltage input using current-output models → Match "U" (voltage) suffix (2810340) or add conversion module (2769653).

Conclusion: Select the Right MCR Module for Precise Signal Processing

The Phoenix MCR series delivers versatile, high-precision solutions for industrial signal conditioning, conversion, and power supply, with specialized models for temperature, current, voltage, frequency, and explosion-proof scenarios. 

Phoenix MCR Series Signal Conditioning & Conversion Modules Selection Guide: Precise Matching of Part Number, Model, and Application