Phoenix MCR Series Signal Conditioning & Conversion Modules Selection Guide: Precise Matching of Part Number, Model, and Application
Opening: High-Precision Industrial Signal Processing Solutions – One-Stop Part Number & Model Reference
In industrial automation and process control systems, accurate signal conditioning, conversion, and isolation are critical for reliable data transmission and control execution. The Phoenix MCR series offers a comprehensive portfolio of modular solutions, covering temperature measurement, signal conversion, power supply, and explosion-proof applications (EX series). With high precision, flexible configuration, and industrial-grade durability, the MCR series is widely used in process manufacturing, energy, and intelligent production scenarios. This guide integrates part number-model correspondence, core technical parameters, and scenario-specific recommendations to simplify technical selection and procurement, helping you quickly lock in optimal signal processing solutions.
I. Core Advantages: Why Choose the Phoenix MCR Series?
- Full signal compatibility: Covers temperature (PT100), current (4-20mA), voltage (0-10V), frequency, and digital signals, meeting multi-type signal processing needs.
- Flexible installation & configuration: Supports Push-in (SP) quick connection, low-profile (LP) design, and modular DIN rail mounting, adapting to space-constrained control cabinets.
- High precision & stability: Signal transmission accuracy up to ±0.1%, anti-electromagnetic interference (EMI), suitable for harsh industrial environments (-40°C to +70°C).
- Specialized functional designs: Includes explosion-proof (EX) models for hazardous areas, dual-output power supplies, and USB-configurable modules, enhancing system adaptability.
- Easy integration: Compatible with Phoenix’s industrial ecosystem, supporting seamless connection with PLCs, sensors, and actuators.
II. Complete Product Series Selection Table (Part Number + Model + Core Information)
1. MCR-SL Series: Signal Conditioning & Isolation Modules (Most Widely Used)
Designed for signal isolation, conversion, and conditioning, supporting temperature, current, voltage, and frequency signals.
| Part Number | Complete Model | Core Functions | Key Specifications | Application Scenario |
|---|---|---|---|---|
| 2306427 | MCR-SL-PT100-SP/SO139 | PT100 temperature signal isolation, Push-in connection, SO139 terminal | Input: PT100; Output: Isolated signal; Connection: Push-in (SP) | Rapid-installation temperature measurement (e.g., pipeline temperature monitoring) |
| 2814948 | MCR-SL-PT100-SP | PT100 temperature signal conditioning, Push-in connection | Input: PT100; Connection: Push-in (SP) | General industrial temperature sensing, quick wiring projects |
| 2864558 | MCR-SL-PT100-LP-I | PT100 temperature-to-current conversion, low-profile (LP) design | Input: PT100; Output: 4-20mA; Installation: Low-profile | Space-constrained control cabinets, compact equipment temperature monitoring |
| 2814883 | MCR-SL-PT100-I-DC-24 | PT100 temperature-to-current conversion, 24V DC powered | Input: PT100; Output: 4-20mA; Power: 24DC | 24V DC automation systems (e.g., PLC-linked temperature transmission) |
| 2814359 | MCR-SLP-1-5-UI-0 | 1-5V voltage signal isolation & conversion | Input: 1-5V; Output: Isolated voltage; Protection: 4KV surge | Voltage signal transmission in high-interference environments (e.g., sensor signal conditioning) |
| 2864516 | MCR-SL-HT-PT 100-I | High-temperature PT100 signal-to-current conversion | Input: PT100 (high-temperature range); Output: 4-20mA | High-temperature process monitoring (e.g., reaction 釜 temperature measurement) |
| 2864011 | MCR-SL-D-U-I | Current-to-voltage signal conversion (dual-channel) | Input: 4-20mA; Output: 0-10V; Channels: 2 | Dual-channel signal conversion (e.g., flow/pressure signal integration) |
| 2710314 | MCR-SL-D-SPA-UI | Dual-channel signal isolation with Push-in connection | Input: Universal (current/voltage); Output: Isolated signal; Connection: SP | Batch-installation dual-channel signal processing (e.g., production line multi-point monitoring) |
| 2810081 | MCR-SL-D-RA | Dual-channel signal conversion with relay output | Input: Universal; Output: Relay contact; Channels: 2 | Signal-triggered switching (e.g., temperature/pressure limit control) |
| 2864024 | MCR-SL-D-FIT | Dual-channel signal conditioning (customizable fit) | Input/Output: Configurable; Channels: 2 | Customized signal processing (e.g., non-standard sensor signal adaptation) |
| 2814841 | MCR-SL-1CLP-I-I-00-4KV | Single-channel current isolation, 4KV surge protection | Input/Output: 4-20mA; Protection: 4KV; Channels: 1 | High-voltage interference environments (e.g., power plant signal transmission) |
2. MCR-SGA/R Series: Signal Distribution & Conversion Modules
Specialized in signal distribution (SGA) and current/voltage conversion (R), suitable for multi-device signal sharing.
| Part Number | Complete Model | Core Functions | Key Specifications | Application Scenario |
|---|---|---|---|---|
| 5604058 | MCR-SGA-4/6-DC | 4-input 6-output signal distributor, DC-powered | Input: Universal; Output: 6-way isolated signal; Power: DC | Multi-device signal sharing (e.g., one sensor signal to 6 PLC inputs) |
| 2769637 | MCR-R-U-V | Voltage-to-voltage signal conversion (0-10V → 0-10V) | Input: 0-10V; Output: 0-10V; Isolation: Yes | Voltage signal amplification/conditioning (e.g., weak signal enhancement) |
| 2769653 | MCR-R-I-4-V-DC | 4-20mA current-to-0-10V voltage conversion, DC-powered | Input: 4-20mA; Output: 0-10V; Power: 24DC | PLC analog input adaptation (e.g., current sensor to voltage signal) |
| 2769624 | MCR-R-I-4-V | 4-20mA current-to-0-10V voltage conversion (universal power) | Input: 4-20mA; Output: 0-10V; Power: AC/DC universal | Mixed-power system signal conversion (e.g., traditional relay cabinet upgrades) |
3. MCR-PT100 Series: Dedicated Temperature Transmitter Modules
Optimized for PT100 thermal resistance signals, providing high-precision temperature-to-current/voltage conversion.
| Part Number | Complete Model | Core Functions | Key Specifications | Application Scenario |
|---|---|---|---|---|
| 2810418 | MCR-PT100-U-NC | PT100 temperature-to-voltage conversion, non-contact (NC) | Input: PT100; Output: 0-10V; Design: Non-contact | High-reliability temperature monitoring (e.g., cleanroom equipment) |
| 2810311 | MCR-PT100-U-DC | PT100 temperature-to-voltage conversion, 24V DC powered | Input: PT100; Output: 0-10V; Power: 24DC | DC-powered automation systems (e.g., battery-operated monitoring devices) |
| 2810340 | MCR-PT100-U | PT100 temperature-to-voltage conversion (universal power) | Input: PT100; Output: 0-10V; Power: AC/DC | General temperature-to-voltage transmission (e.g., HVAC system temperature monitoring) |
| 2810447 | MCR-PT100-I-DC-NC | PT100 temperature-to-current conversion, DC-powered, non-contact | Input: PT100; Output: 4-20mA; Power: 24DC; NC | High-precision industrial temperature sensing (e.g., pharmaceutical reactor temperature control) |
| 2810353 | MCR-PT100-I | PT100 temperature-to-current conversion (universal power) | Input: PT100; Output: 4-20mA; Power: AC/DC | Standard temperature-to-current transmission (e.g., pipeline pressure/temperature integration) |
| 2810337 | MCR-PT100/I/DC | PT100 temperature-to-current conversion, DC-powered (compact) | Input: PT100; Output: 4-20mA; Power: 24DC | Compact control cabinets (e.g., small-scale equipment temperature monitoring) |
4. MCR-PS/PAC Series: Power Supply & Auxiliary Modules
Provides stable power supply (PS) and USB-configurable auxiliary functions (PAC) for system integration.
| Part Number | Complete Model | Core Functions | Key Specifications | Application Scenario |
|---|---|---|---|---|
| 2811925 | MCR-PSP-DC | DC power supply module (protected) | Output: Stable DC voltage; Protection: Overload/short-circuit | Sensor/module power supply (e.g., 24V DC sensor power distribution) |
| 2811912 | MCR-PSP | Universal power supply module (protected) | Output: AC/DC configurable; Protection: Overload/short-circuit | Mixed-power system power supply (e.g., control cabinet auxiliary power) |
| 2766685 | MCR-PS-24DC-10DC | 24V DC input → 10V DC output power converter | Input: 24DC; Output: 10DC; Power: 200mA | Low-voltage sensor power supply (e.g., weak signal sensor dedicated power) |
| 2781877 | MCR-PS-24DC/2X24DC | 24V DC input → dual 24V DC output power supply | Input: 24DC; Output: 2×24DC; Power: 200mA×2 | Dual-device power supply (e.g., two sensors/actuators parallel power) |
| 2766821 | MCR-PS-24DC/24DC/200 | 24V DC input → 24V DC output (200mA) power supply | Input: 24DC; Output: 24DC; Current: 200mA | Low-current module power supply (e.g., signal conditioning module power) |
| 2309000 | MCR-PAC-T-USB | USB-configurable auxiliary module | Interface: USB; Function: Parameter configuration | Custom signal processing (e.g., module parameter programming via PC) |
5. MCR-F/FL Series: Frequency & Explosion-Proof Temperature Modules
Covers frequency signal conditioning (F) and explosion-proof temperature processing (FL-EX), suitable for special scenarios.
| Part Number | Complete Model | Core Functions | Key Specifications | Application Scenario |
|---|---|---|---|---|
| 2814605 | MCR-F-UI-DC | Frequency-to-voltage/current conversion, DC-powered | Input: Frequency; Output: 0-10V/4-20mA; Power: 24DC | Speed/flow signal conversion (e.g., pump/motor speed monitoring) |
| 2864587 | MCR-FL-TS-LP-I-EX | Explosion-proof (EX) temperature signal conditioning, low-profile | Input: Thermocouple/PT100; Output: 4-20mA; Certification: Ex | Hazardous area temperature monitoring (e.g., petrochemical plant pipeline temperature) |
| 2864574 | MCR-FL-T-LP-I-EX | Explosion-proof temperature-to-current conversion, low-profile | Input: Thermocouple; Output: 4-20mA; Certification: Ex; LP | Explosion-proof area compact temperature sensing (e.g., hazardous zone equipment temperature) |
| 2864561 | MCR-FL-T-LP-I | Temperature-to-current conversion, low-profile (non-explosion-proof) | Input: Thermocouple; Output: 4-20mA; LP | General industrial low-profile temperature monitoring (e.g., compact reactor temperature) |
| 2864545 | MCR-FL-HT-TS-I-EX | Explosion-proof high-temperature signal conditioning | Input: High-temperature thermocouple/PT100; Output: 4-20mA; Ex | Explosion-proof high-temperature scenarios (e.g., refinery furnace temperature) |
| 2864532 | MCR-FL-HT-T-I-EX | Explosion-proof high-temperature temperature-to-current conversion | Input: High-temperature thermocouple; Output: 4-20mA; Ex | Hazardous area high-temperature monitoring (e.g., chemical reaction temperature control) |
| 2864529 | MCR-FL-HT-T-I | High-temperature temperature-to-current conversion (non-explosion-proof) | Input: High-temperature thermocouple; Output: 4-20mA | General high-temperature process monitoring (e.g., steel mill equipment temperature) |
III. 3-Step Quick Selection Technique (Easy for Beginners)
Step 1: Determine Core Function & Signal Type
- Temperature measurement (PT100/thermocouple):
- General temperature → MCR-PT100 series (e.g., 2810353);
- High-temperature → MCR-SL-HT/FL-HT series (e.g., 2864516, 2864529);
- Explosion-proof area → MCR-FL-EX series (e.g., 2864574).
- Current/voltage conversion: MCR-R/SL series (e.g., 2769653, 2864011).
- Signal distribution: MCR-SGA series (e.g., 5604058).
- Power supply: MCR-PS series (e.g., 2781877).
- Frequency signal: MCR-F series (e.g., 2814605).
Step 2: Confirm Input/Output & Power Requirements
- Input signal: PT100 → select "PT100" models; thermocouple → "T/TS" models; current → "I" models; voltage → "U" models.
- Output signal: Need 4-20mA → "I" suffix; 0-10V → "U" suffix; relay → "RA" suffix.
- Power supply: 24V DC (most automation systems) → "DC-24" models; universal power → no voltage suffix.
Step 3: Select Special Requirements
- Installation: Quick wiring → Push-in (SP suffix, e.g., 2814948); space-constrained → low-profile (LP suffix, e.g., 2864558).
- Explosion-proof: Hazardous areas (Zone 0/1/2) → "EX" suffix models (e.g., 2864574).
- Protection: High-interference environments → 4KV surge protection (e.g., 2814841).
- Configuration: Custom parameters → USB-configurable (MCR-PAC-T-USB, 2309000).
IV. Recommended Industry-Scenario Combinations (Ready-to-Use)
| Industry | Typical Scenario | Recommended Model Combination |
|---|---|---|
| Petrochemical (Explosion-Proof) | Hazardous area high-temperature monitoring | 2864532 (MCR-FL-HT-T-I-EX) + 2769653 (MCR-R-I-4-V-DC) |
| Industrial Automation | PT100 temperature → PLC voltage input | 2810353 (MCR-PT100-I) + 5604058 (MCR-SGA-4/6-DC) |
| Process Control | High-interference current signal transmission | 2814841 (MCR-SL-1CLP-I-I-00-4KV) + 2781877 (MCR-PS-24DC/2X24DC) |
| Compact Control Cabinets | Low-profile temperature + power supply | 2864558 (MCR-SL-PT100-LP-I) + 2766821 (MCR-PS-24DC/24DC/200) |
| HVAC Systems | Temperature-to-voltage signal conversion | 2810340 (MCR-PT100-U) + 2769637 (MCR-R-U-V) |
V. Selection Pitfall Avoidance Guide (Common Mistakes to Note)
- Explosion-proof misuse: Non-EX models used in hazardous areas → Only "EX" suffix models (2864574) are compliant with explosion-proof standards.
- Signal mismatch: PT100 input using thermocouple models → Confirm "PT100" in model (e.g., 2814948) for temperature compatibility.
- Power supply error: 24DC system using AC-powered models → Check "DC" suffix (e.g., 2814883) to avoid module burnout.
- Space neglect: Compact cabinets using standard-profile models → Select LP suffix (2864558) for low-profile installation.
- Interference ignoring: High-voltage environments using unprotected models → Choose 4KV surge protection (2814841) to prevent signal distortion.
- Output type error: PLC requiring voltage input using current-output models → Match "U" (voltage) suffix (2810340) or add conversion module (2769653).
Conclusion: Select the Right MCR Module for Precise Signal Processing
The Phoenix MCR series delivers versatile, high-precision solutions for industrial signal conditioning, conversion, and power supply, with specialized models for temperature, current, voltage, frequency, and explosion-proof scenarios.