Phoenix RIF Series Relay Selection Guide: Precise Part Number & Model Matching

Opening: Reliable Industrial Relay Solutions for Signal Switching & Surge Protection

In industrial automation control systems, relays with stable switching performance, surge protection, and multi-voltage adaptation are critical for circuit interlocking, signal amplification, and load control. The Phoenix RIF-1-RPT series stands out with dual functional variants (standard LV/ surge-protected LDP), wide AC/DC voltage compatibility (24V/120V/230V), and flexible contact configurations, widely used in motor control, sensor-triggered circuits, and safety interlock systems. This guide integrates part number-model correspondence, core technical parameters, and scenario-specific recommendations to simplify selection and procurement, helping you quickly lock in optimal relay solutions.


I. Core Advantages: Why Choose the Phoenix RIF Series?

  • Dual functional variants:
    • LV (Standard type): Basic switching for general industrial scenarios;
    • LDP (Surge protection type): Built-in surge suppression for inductive loads (motors, solenoids), extending relay life.
  • Wide voltage compatibility: Supports 24AC/230AC/120AC (AC systems) and 24DC (DC automation systems), adapting to global industrial power standards.
  • Flexible contact configurations: Dual changeover contacts (2X21), single changeover contact (1X21), special normally open contacts (1X21AU), and integrated contacts (1IC), meeting diverse circuit needs.
  • Industrial-grade reliability: Operating temperature range of -25°C to +60°C, anti-vibration design (IEC 60068-2-6), suitable for harsh factory environments.
  • Special function integration: Ground terminal (FG) for safety interlocks, MS-type special contacts for custom circuits, ensuring system safety and flexibility.

II. Complete Product Series Selection Table (Part Number + Model + Core Information)

1. RIF-1-RPT-LV Series: Standard Type Relays (No Surge Protection)

Designed for general industrial switching scenarios (non-inductive loads, low surge risk).

Part Number Complete Model Core Functions Key Specifications Application Scenario
2903333 RIF-1-RPT-LV-24AC/2X21 24V AC control, 2× changeover contacts (2X21) Voltage: 24AC; Contacts: 2X21; Type: Standard (LV) 24V AC small-signal switching (e.g., sensor-triggered actuator control)
2903337 RIF-1-RPT-LV-24AC/1X21AU 24V AC control, 1× special normally open contact (1X21AU) Voltage: 24AC; Contacts: 1X21AU; Type: Standard (LV) 24V AC special load switching (e.g., low-power inductive loads without surge risk)
2903341 RIF-1-RPT-LV-24AC/1X21 24V AC control, 1× changeover contact (1X21) Voltage: 24AC; Contacts: 1X21; Type: Standard (LV) 24V AC single-circuit switching (e.g., indicator light control, signal feedback)
2905292 RIF-1-RPT-LV-230AC/2X21MS 230V AC control, 2× changeover contacts (2X21), MS special function Voltage: 230AC; Contacts: 2X21MS; Type: Standard (LV) 230V AC mains-powered equipment (e.g., HVAC fan control, lighting switching)
2903327 RIF-1-RPT-LV-230AC/2X21AU 230V AC control, 2× special normally open contacts (2X21AU) Voltage: 230AC; Contacts: 2X21AU; Type: Standard (LV) 230V AC multi-channel special load switching (e.g., small pump group control)
2903331 RIF-1-RPT-LV-230AC/2x21 230V AC control, 2× changeover contacts (2X21) Voltage: 230AC; Contacts: 2X21; Type: Standard (LV) 230V AC dual-circuit switching (e.g., alternative power supply selection)
2903339 RIF-1-RPT-LV-230AC/1X21 230V AC control, 1× changeover contact (1X21) Voltage: 230AC; Contacts: 1X21; Type: Standard (LV) 230V AC single-circuit mains equipment (e.g., industrial heater control)
2903332 RIF-1-RPT-LV-120AC/2X21 120V AC control, 2× changeover contacts (2X21) Voltage: 120AC; Contacts: 2X21; Type: Standard (LV) North American market 120AC systems (e.g., commercial equipment control)
2909776 RIF-1-RPT-LV-120AC/1X21MS 120V AC control, 1× changeover contact (1X21MS), MS special function Voltage: 120AC; Contacts: 1X21MS; Type: Standard (LV) North American special equipment switching (e.g., legacy control system upgrades)
2903340 RIF-1-RPT-LV-120AC/1X21 120V AC control, 1× changeover contact (1X21) Voltage: 120AC; Contacts: 1X21; Type: Standard (LV) North American general 120AC circuit switching (e.g., workshop lighting)

2. RIF-1-RPT-LDP Series: Surge Protection Relays (Built-in LDP Circuit)

Equipped with surge suppression for inductive loads (motors, solenoids), suitable for harsh environments with voltage spikes.

Part Number Complete Model Core Functions Key Specifications Application Scenario
2905291 RIF-1-RPT-LDP-24DC/2X21MS 24V DC control, 2× changeover contacts (2X21MS), surge protection (LDP) Voltage: 24DC; Contacts: 2X21MS; Type: Surge Protection (LDP) 24V DC motor control (e.g., conveyor belt drive, with surge suppression)
2903330 RIF-1-RPT-LDP-24DC/2X21AU 24V DC control, 2× special normally open contacts (2X21AU), surge protection Voltage: 24DC; Contacts: 2X21AU; Type: LDP 24V DC dual-channel inductive load switching (e.g., dual solenoid valves)
2908215 RIF-1-RPT-LDP-24DC/2X21/FG 24V DC control, 2× changeover contacts (2X21), surge protection, ground terminal (FG) Voltage: 24DC; Contacts: 2X21; Feature: FG (Ground); Type: LDP 24V DC safety interlock circuits (e.g., emergency stop systems with ground protection)
2903334 RIF-1-RPT-LDP-24DC/2x21 24V DC control, 2× changeover contacts (2X21), surge protection Voltage: 24DC; Contacts: 2X21; Type: LDP 24V DC general inductive load switching (e.g., small pump control)
2905289 RIF-1-RPT-LDP-24DC/1X21MS 24V DC control, 1× changeover contact (1X21MS), surge protection Voltage: 24DC; Contacts: 1X21MS; Type: LDP 24V DC single-channel high-reliability switching (e.g., precision actuator control)
2903338 RIF-1-RPT-LDP-24DC/1X21AU 24V DC control, 1× special normally open contact (1X21AU), surge protection Voltage: 24DC; Contacts: 1X21AU; Type: LDP 24V DC special inductive load switching (e.g., high-precision sensor triggers)
2903342 RIF-1-RPT-LDP-24DC/1x21 24V DC control, 1× changeover contact (1X21), surge protection Voltage: 24DC; Contacts: 1X21; Type: LDP 24V DC single-circuit inductive load (e.g., limit switch-triggered relays)
2909884 RIF-1-RPT-LDP-24DC/1IC 24V DC control, 1× integrated contact (1IC), surge protection Voltage: 24DC; Contacts: 1IC; Type: LDP 24V DC compact control systems (e.g., IoT edge device signal switching)

III. RIF Series Nomenclature Explanation (Key to Model Understanding)

RIF-1-RPT-[Suffix1]-[Voltage]/[Contact Configuration]-[Special Feature]

  • Suffix1 (Function Type): LV = Standard type (no surge protection); LDP = Surge protection type (for inductive loads).
  • Voltage: 24AC/230AC/120AC (AC control) | 24DC (DC control).
  • Contact Configuration:
    • 2X21 = 2× changeover contacts (1NO + 1NC per contact);
    • 1X21 = 1× changeover contact;
    • 1X21AU = 1× special normally open contact (enhanced load capacity);
    • 1IC = 1× integrated contact (compact design);
    • MS = Special function contact (custom circuit adaptation).
  • Special Feature: FG = Ground terminal (safety interlock); no suffix = standard design.

IV. 3-Step Quick Selection Technique (Easy for Beginners)

Step 1: Select Function Type (LV/LDP)

  • General loads (resistive, no surge): Standard type (LV) → 2903333, 2903331.
  • Inductive loads (motors, solenoids, voltage spikes): Surge protection type (LDP) → 2903334, 2908215.

Step 2: Confirm Control Voltage

  • Automation systems (global standard): 24DC/24AC → 2903334 (24DC LDP), 2903333 (24AC LV).
  • Mains power (Europe/Asia): 230AC → 2903331 (LV), 2903330 (LDP).
  • North American market: 120AC → 2903332 (LV), 2909776 (LV MS).

Step 3: Choose Contact Configuration & Special Features

  • Dual-circuit switching: 2X21/2X21AU → 2903333 (2X21), 2903330 (2X21AU).
  • Single-circuit switching: 1X21/1X21AU → 2903341 (1X21), 2903338 (1X21AU).
  • Safety interlock: FG suffix (ground protection) → 2908215.
  • Compact design: 1IC (integrated contact) → 2909884.
  • Custom circuits: MS suffix (special contact) → 2905292, 2905291.

V. Recommended Industry-Scenario Combinations (Ready-to-Use)

Industry Typical Scenario Recommended Model Combination
Factory Automation 24DC motor control (surge protection + dual-circuit) 2903334 (RIF-1-RPT-LDP-24DC/2x21) + 2908215 (RIF-1-RPT-LDP-24DC/2X21/FG)
HVAC Systems 230AC fan/lighting dual-circuit switching 2903331 (RIF-1-RPT-LV-230AC/2x21) + 2903339 (RIF-1-RPT-LV-230AC/1X21)
North American Commercial Equipment 120AC legacy system upgrade (special function) 2909776 (RIF-1-RPT-LV-120AC/1X21MS) + 2903340 (RIF-1-RPT-LV-120AC/1X21)
Safety Interlock Systems 24DC emergency stop circuit (ground + surge protection) 2908215 (RIF-1-RPT-LDP-24DC/2X21/FG) + 2903342 (RIF-1-RPT-LDP-24DC/1x21)
Compact Control Cabinets 24DC IoT device signal switching 2909884 (RIF-1-RPT-LDP-24DC/1IC) + 2903338 (RIF-1-RPT-LDP-24DC/1X21AU)

VI. Selection Pitfall Avoidance Guide (Common Mistakes to Note)

  1. Surge protection neglect: Inductive loads (motors/solenoids) using LV models → Select LDP suffix (2903334) to suppress voltage spikes and avoid relay damage.
  2. Voltage mismatch: 24DC system using AC models (e.g., 230AC) → Confirm voltage in model (AC/DC) to prevent burnout.
  3. Contact configuration error: Dual-circuit needs using single-circuit relays → Choose 2X21 (dual changeover) for multi-circuit switching.
  4. Safety interlock missing: Emergency stop circuits without FG models → Select FG suffix (2908215) for ground protection, complying with safety standards.
  5. North American market incompatibility: Using 230AC models for 120AC systems → Choose 120AC-specific models (2903332, 2909776).
  6. Special load mismatch: High-reliability loads using standard contacts → Select 21AU (special 常开) or MS (special function) models for enhanced performance.

Conclusion: Select the Right RIF Relay for Stable Industrial Control

The Phoenix RIF-1-RPT series provides targeted solutions for general switching and inductive load protection, with LV/LDP dual variants, multi-voltage compatibility, and flexible contact configurations adapting to global industrial scenarios. 

Phoenix RIF Series Relay Selection Guide: Precise Part Number & Model Matching

Created on:2025-12-04 13:35

News Dynamics

NEWS