Phoenix RIF Series Relay Selection Guide: Precise Part Number & Model Matching
Opening: Reliable Industrial Relay Solutions for Signal Switching & Surge Protection
In industrial automation control systems, relays with stable switching performance, surge protection, and multi-voltage adaptation are critical for circuit interlocking, signal amplification, and load control. The Phoenix RIF-1-RPT series stands out with dual functional variants (standard LV/ surge-protected LDP), wide AC/DC voltage compatibility (24V/120V/230V), and flexible contact configurations, widely used in motor control, sensor-triggered circuits, and safety interlock systems. This guide integrates part number-model correspondence, core technical parameters, and scenario-specific recommendations to simplify selection and procurement, helping you quickly lock in optimal relay solutions.
I. Core Advantages: Why Choose the Phoenix RIF Series?
- Dual functional variants:
- LV (Standard type): Basic switching for general industrial scenarios;
- LDP (Surge protection type): Built-in surge suppression for inductive loads (motors, solenoids), extending relay life.
- Wide voltage compatibility: Supports 24AC/230AC/120AC (AC systems) and 24DC (DC automation systems), adapting to global industrial power standards.
- Flexible contact configurations: Dual changeover contacts (2X21), single changeover contact (1X21), special normally open contacts (1X21AU), and integrated contacts (1IC), meeting diverse circuit needs.
- Industrial-grade reliability: Operating temperature range of -25°C to +60°C, anti-vibration design (IEC 60068-2-6), suitable for harsh factory environments.
- Special function integration: Ground terminal (FG) for safety interlocks, MS-type special contacts for custom circuits, ensuring system safety and flexibility.
II. Complete Product Series Selection Table (Part Number + Model + Core Information)
1. RIF-1-RPT-LV Series: Standard Type Relays (No Surge Protection)
Designed for general industrial switching scenarios (non-inductive loads, low surge risk).
| Part Number | Complete Model | Core Functions | Key Specifications | Application Scenario |
|---|---|---|---|---|
| 2903333 | RIF-1-RPT-LV-24AC/2X21 | 24V AC control, 2× changeover contacts (2X21) | Voltage: 24AC; Contacts: 2X21; Type: Standard (LV) | 24V AC small-signal switching (e.g., sensor-triggered actuator control) |
| 2903337 | RIF-1-RPT-LV-24AC/1X21AU | 24V AC control, 1× special normally open contact (1X21AU) | Voltage: 24AC; Contacts: 1X21AU; Type: Standard (LV) | 24V AC special load switching (e.g., low-power inductive loads without surge risk) |
| 2903341 | RIF-1-RPT-LV-24AC/1X21 | 24V AC control, 1× changeover contact (1X21) | Voltage: 24AC; Contacts: 1X21; Type: Standard (LV) | 24V AC single-circuit switching (e.g., indicator light control, signal feedback) |
| 2905292 | RIF-1-RPT-LV-230AC/2X21MS | 230V AC control, 2× changeover contacts (2X21), MS special function | Voltage: 230AC; Contacts: 2X21MS; Type: Standard (LV) | 230V AC mains-powered equipment (e.g., HVAC fan control, lighting switching) |
| 2903327 | RIF-1-RPT-LV-230AC/2X21AU | 230V AC control, 2× special normally open contacts (2X21AU) | Voltage: 230AC; Contacts: 2X21AU; Type: Standard (LV) | 230V AC multi-channel special load switching (e.g., small pump group control) |
| 2903331 | RIF-1-RPT-LV-230AC/2x21 | 230V AC control, 2× changeover contacts (2X21) | Voltage: 230AC; Contacts: 2X21; Type: Standard (LV) | 230V AC dual-circuit switching (e.g., alternative power supply selection) |
| 2903339 | RIF-1-RPT-LV-230AC/1X21 | 230V AC control, 1× changeover contact (1X21) | Voltage: 230AC; Contacts: 1X21; Type: Standard (LV) | 230V AC single-circuit mains equipment (e.g., industrial heater control) |
| 2903332 | RIF-1-RPT-LV-120AC/2X21 | 120V AC control, 2× changeover contacts (2X21) | Voltage: 120AC; Contacts: 2X21; Type: Standard (LV) | North American market 120AC systems (e.g., commercial equipment control) |
| 2909776 | RIF-1-RPT-LV-120AC/1X21MS | 120V AC control, 1× changeover contact (1X21MS), MS special function | Voltage: 120AC; Contacts: 1X21MS; Type: Standard (LV) | North American special equipment switching (e.g., legacy control system upgrades) |
| 2903340 | RIF-1-RPT-LV-120AC/1X21 | 120V AC control, 1× changeover contact (1X21) | Voltage: 120AC; Contacts: 1X21; Type: Standard (LV) | North American general 120AC circuit switching (e.g., workshop lighting) |
2. RIF-1-RPT-LDP Series: Surge Protection Relays (Built-in LDP Circuit)
Equipped with surge suppression for inductive loads (motors, solenoids), suitable for harsh environments with voltage spikes.
| Part Number | Complete Model | Core Functions | Key Specifications | Application Scenario |
|---|---|---|---|---|
| 2905291 | RIF-1-RPT-LDP-24DC/2X21MS | 24V DC control, 2× changeover contacts (2X21MS), surge protection (LDP) | Voltage: 24DC; Contacts: 2X21MS; Type: Surge Protection (LDP) | 24V DC motor control (e.g., conveyor belt drive, with surge suppression) |
| 2903330 | RIF-1-RPT-LDP-24DC/2X21AU | 24V DC control, 2× special normally open contacts (2X21AU), surge protection | Voltage: 24DC; Contacts: 2X21AU; Type: LDP | 24V DC dual-channel inductive load switching (e.g., dual solenoid valves) |
| 2908215 | RIF-1-RPT-LDP-24DC/2X21/FG | 24V DC control, 2× changeover contacts (2X21), surge protection, ground terminal (FG) | Voltage: 24DC; Contacts: 2X21; Feature: FG (Ground); Type: LDP | 24V DC safety interlock circuits (e.g., emergency stop systems with ground protection) |
| 2903334 | RIF-1-RPT-LDP-24DC/2x21 | 24V DC control, 2× changeover contacts (2X21), surge protection | Voltage: 24DC; Contacts: 2X21; Type: LDP | 24V DC general inductive load switching (e.g., small pump control) |
| 2905289 | RIF-1-RPT-LDP-24DC/1X21MS | 24V DC control, 1× changeover contact (1X21MS), surge protection | Voltage: 24DC; Contacts: 1X21MS; Type: LDP | 24V DC single-channel high-reliability switching (e.g., precision actuator control) |
| 2903338 | RIF-1-RPT-LDP-24DC/1X21AU | 24V DC control, 1× special normally open contact (1X21AU), surge protection | Voltage: 24DC; Contacts: 1X21AU; Type: LDP | 24V DC special inductive load switching (e.g., high-precision sensor triggers) |
| 2903342 | RIF-1-RPT-LDP-24DC/1x21 | 24V DC control, 1× changeover contact (1X21), surge protection | Voltage: 24DC; Contacts: 1X21; Type: LDP | 24V DC single-circuit inductive load (e.g., limit switch-triggered relays) |
| 2909884 | RIF-1-RPT-LDP-24DC/1IC | 24V DC control, 1× integrated contact (1IC), surge protection | Voltage: 24DC; Contacts: 1IC; Type: LDP | 24V DC compact control systems (e.g., IoT edge device signal switching) |
III. RIF Series Nomenclature Explanation (Key to Model Understanding)
RIF-1-RPT-[Suffix1]-[Voltage]/[Contact Configuration]-[Special Feature]
- Suffix1 (Function Type): LV = Standard type (no surge protection); LDP = Surge protection type (for inductive loads).
- Voltage: 24AC/230AC/120AC (AC control) | 24DC (DC control).
- Contact Configuration:
- 2X21 = 2× changeover contacts (1NO + 1NC per contact);
- 1X21 = 1× changeover contact;
- 1X21AU = 1× special normally open contact (enhanced load capacity);
- 1IC = 1× integrated contact (compact design);
- MS = Special function contact (custom circuit adaptation).
- Special Feature: FG = Ground terminal (safety interlock); no suffix = standard design.
IV. 3-Step Quick Selection Technique (Easy for Beginners)
Step 1: Select Function Type (LV/LDP)
- General loads (resistive, no surge): Standard type (LV) → 2903333, 2903331.
- Inductive loads (motors, solenoids, voltage spikes): Surge protection type (LDP) → 2903334, 2908215.
Step 2: Confirm Control Voltage
- Automation systems (global standard): 24DC/24AC → 2903334 (24DC LDP), 2903333 (24AC LV).
- Mains power (Europe/Asia): 230AC → 2903331 (LV), 2903330 (LDP).
- North American market: 120AC → 2903332 (LV), 2909776 (LV MS).
Step 3: Choose Contact Configuration & Special Features
- Dual-circuit switching: 2X21/2X21AU → 2903333 (2X21), 2903330 (2X21AU).
- Single-circuit switching: 1X21/1X21AU → 2903341 (1X21), 2903338 (1X21AU).
- Safety interlock: FG suffix (ground protection) → 2908215.
- Compact design: 1IC (integrated contact) → 2909884.
- Custom circuits: MS suffix (special contact) → 2905292, 2905291.
V. Recommended Industry-Scenario Combinations (Ready-to-Use)
| Industry | Typical Scenario | Recommended Model Combination |
|---|---|---|
| Factory Automation | 24DC motor control (surge protection + dual-circuit) | 2903334 (RIF-1-RPT-LDP-24DC/2x21) + 2908215 (RIF-1-RPT-LDP-24DC/2X21/FG) |
| HVAC Systems | 230AC fan/lighting dual-circuit switching | 2903331 (RIF-1-RPT-LV-230AC/2x21) + 2903339 (RIF-1-RPT-LV-230AC/1X21) |
| North American Commercial Equipment | 120AC legacy system upgrade (special function) | 2909776 (RIF-1-RPT-LV-120AC/1X21MS) + 2903340 (RIF-1-RPT-LV-120AC/1X21) |
| Safety Interlock Systems | 24DC emergency stop circuit (ground + surge protection) | 2908215 (RIF-1-RPT-LDP-24DC/2X21/FG) + 2903342 (RIF-1-RPT-LDP-24DC/1x21) |
| Compact Control Cabinets | 24DC IoT device signal switching | 2909884 (RIF-1-RPT-LDP-24DC/1IC) + 2903338 (RIF-1-RPT-LDP-24DC/1X21AU) |
VI. Selection Pitfall Avoidance Guide (Common Mistakes to Note)
- Surge protection neglect: Inductive loads (motors/solenoids) using LV models → Select LDP suffix (2903334) to suppress voltage spikes and avoid relay damage.
- Voltage mismatch: 24DC system using AC models (e.g., 230AC) → Confirm voltage in model (AC/DC) to prevent burnout.
- Contact configuration error: Dual-circuit needs using single-circuit relays → Choose 2X21 (dual changeover) for multi-circuit switching.
- Safety interlock missing: Emergency stop circuits without FG models → Select FG suffix (2908215) for ground protection, complying with safety standards.
- North American market incompatibility: Using 230AC models for 120AC systems → Choose 120AC-specific models (2903332, 2909776).
- Special load mismatch: High-reliability loads using standard contacts → Select 21AU (special 常开) or MS (special function) models for enhanced performance.
Conclusion: Select the Right RIF Relay for Stable Industrial Control
The Phoenix RIF-1-RPT series provides targeted solutions for general switching and inductive load protection, with LV/LDP dual variants, multi-voltage compatibility, and flexible contact configurations adapting to global industrial scenarios.