Phoenix SACC-M12MS Series Industrial Connectors Selection Guide (5/6/8-Core M12 Male Straight)

Opening: High-Density M12 Male Connectors for Industrial Protocol & Power Transmission

The Phoenix SACC-M12MS series focuses on M12 male straight (MS) industrial connectors, covering 5/6/8-core configurations and adapting to diverse industrial protocols (Ethernet, VARAN, VA) and power transmission needs. With core features including shielded design (SH), dual-nut locking (DN), compact installation (CM), and thin-profile (SKIN) variants, these connectors support cable gland sizes (PG7/PG9/PG11) and comply with IP67 protection standards. Widely used in factory automation, Ethernet/fieldbus systems, and power distribution, the series ensures stable signal/power transmission in harsh industrial environments. This guide structures part number-model correspondence, core parameters, and scenario recommendations for efficient selection.


I. Core Advantages: Why Choose the SACC-M12MS Series?

  • Multi-core & protocol compatibility: 5/6/8-core options match signal/power needs; supports Ethernet (ETH), VARAN, VA protocols for seamless integration with industrial control systems.
  • Industrial-grade protection: IP67 waterproof/dustproof, shielded (SH) anti-interference, -40°C to +85°C operating temperature, resistant to vibration and oil.
  • Flexible installation & accessories: Cable glands (PG7/PG9/PG11) for different cable diameters; dual-nut (DN) for anti-loosening; compact (CM)/thin (SKIN) designs for space-constrained cabinets.
  • Special function integration: Power-specific (PWR) models for high-current transmission; DUO dual-configuration for versatile wiring; AU (Australian standard) for regional compliance.
  • Reliable connection: Gold-plated contacts (PL/CT series) reduce contact resistance; rigid mechanical locking ensures long-term stability in high-vibration scenarios.

II. Complete Product Selection Table (Part Number + Model + Core Information)

1. 8-Core M12MS Connectors (High-Density Signal/Ethernet)

Suitable for multi-channel signal transmission, Ethernet communication, and high-density sensor arrays.

Part Number Complete Model Core Parameters Application Scenario
1414610 SACC-M12MS-8QO-0,5 SH Core: 8; Coding: QO; Length: 0.5m; Feature: Shielded (SH) Short-distance (0.5m) 8-channel shielded signal transmission (e.g., multi-sensor array wiring)
1421679 SACC-M12MS-8QO SH ETH Core: 8; Coding: QO; Feature: Shielded (SH) + Ethernet (ETH) Industrial Ethernet communication (e.g., PROFINET IO device connection with shielding)
1543236 SACC-M12MS-8Q SH Core: 8; Coding: Q; Feature: Shielded (SH) 8-channel shielded signal transmission (e.g., high-interference industrial Ethernet backup lines)
1513334 SACC-M12MS-8CON-PG9-M Core: 8; Type: CON (cable gland); Gland: PG9; Installation: Fixed (M) 8-core cable fixed connection (PG9 cable diameter, e.g., control cabinet Ethernet distribution)
1410666 SACC-M12MS-8CON-PG11-M Core: 8; Type: CON; Gland: PG11; Installation: Fixed (M) Large-diameter 8-core cable connection (PG11, e.g., heavy-duty Ethernet cable wiring)
1511857 SACC-M12MS-8CON-PG 9-SH Core: 8; Type: CON; Gland: PG9; Feature: Shielded (SH) Shielded 8-core cable connection (PG9, e.g., outdoor Ethernet sensor wiring)

2. 6-Core M12MS Connectors (VARAN Protocol Specialized)

Optimized for VARAN fieldbus systems, suitable for real-time control in automotive, machinery, and automation.

Part Number Complete Model Core Parameters Application Scenario
1429130 SACC-M12MS-6Q SH VARAN Core: 6; Coding: Q; Feature: Shielded (SH) + VARAN protocol VARAN fieldbus real-time control (e.g., automotive production line sensor/actuator interconnection)

3. 5-Core M12MS Connectors (General Signal/Power Transmission)

Most widely used core count, balancing signal and power transmission; supports multiple coding and special functions.

Part Number Complete Model Core Parameters Application Scenario
SC Coding (Standard Signal)      
1549793 SACC-M12MS-5SC SH DN Core: 5; Coding: SC; Feature: Shielded (SH) + Dual-nut (DN) Anti-loosening shielded signal transmission (e.g., vibration-prone machinery sensor wiring)
1512555 SACC-M12MS-5SC SH Core: 5; Coding: SC; Feature: Shielded (SH) Standard 5-channel shielded signal transmission (e.g., proximity sensor + feedback signal)
1508187 SACC-M12MS-5SC M Core: 5; Coding: SC; Installation: Fixed (M) Fixed 5-core signal connection (e.g., control cabinet internal sensor wiring)
QO Coding (Protocol-Specific)      
1426327 SACC-M12MS-5QO-0,5-CM VA Core: 5; Coding: QO; Length: 0.5m; Feature: Compact (CM) + VA protocol Compact 0.5m VA protocol signal transmission (e.g., space-constrained control panel wiring)
PL Coding (Pin-Type Connection)      
1424670 SACC-M12MS-5PL SH DN Core: 5; Coding: PL (pin-type); Feature: Shielded (SH) + Dual-nut (DN) Anti-loosening shielded pin-type connection (e.g., heavy-duty actuator power/signal integration)
1424658 SACC-M12MS-5PL SH Core: 5; Coding: PL; Feature: Shielded (SH) Standard pin-type shielded connection (e.g., precision sensor signal transmission)
1424649 SACC-M12MS-5PL M Core: 5; Coding: PL; Installation: Fixed (M) Fixed pin-type connection (e.g., stationary equipment sensor wiring)
1072543 SACC-M12MS-5PL DN Core: 5; Coding: PL; Feature: Dual-nut (DN) Anti-loosening pin-type connection (e.g., mobile equipment sensor wiring)
1424686 SACC-M12MS-5PL Core: 5; Coding: PL Basic pin-type connection (e.g., non-critical signal transmission)
CT Coding (Special Type)      
1422850 SACC-M12MS-5CT-CM SH Core: 5; Coding: CT; Feature: Compact (CM) + Shielded (SH) Compact shielded special-type connection (e.g., IoT edge device signal wiring)
CON Coding (Cable Gland, Power/Signal)      
1556825 SACC-M12MS-5CON-PG9-M SKIN Core: 5; Type: CON; Gland: PG9; Installation: Fixed (M); Feature: Thin-profile (SKIN) Thin-design 5-core cable connection (PG9, e.g., slim control cabinet wiring)
1456466 SACC-M12MS-5CON-PG7-M SKIN Core: 5; Type: CON; Gland: PG7; Installation: Fixed (M); Feature: Thin-profile (SKIN) Ultra-thin 5-core cable connection (PG7, e.g., micro-sensor wiring)
1404417 SACC-M12MS-5CON-PG11-M PWR Core: 5; Type: CON; Gland: PG11; Installation: Fixed (M); Feature: Power (PWR) 5-core power transmission (PG11, e.g., small motor power supply)
1662748 SACC-M12MS-5CON-PG11-DUO-M Core: 5; Type: CON; Gland: PG11; Feature: Dual-configuration (DUO) + Fixed (M) Versatile dual-mode 5-core connection (PG11, e.g., backup power/signal integration)
1662285 SACC-M12MS-5CON-PG11-DUO Core: 5; Type: CON; Gland: PG11; Feature: Dual-configuration (DUO) Basic dual-mode 5-core connection (PG11, e.g., flexible wiring for modular equipment)
1553190 SACC-M12MS-5CON-PG 9-VA Core: 5; Type: CON; Gland: PG9; Feature: VA protocol VA protocol 5-core cable connection (PG9, e.g., process control equipment wiring)
1694266 SACC-M12MS-5CON-PG 9-SH Core: 5; Type: CON; Gland: PG9; Feature: Shielded (SH) Shielded 5-core cable connection (PG9, e.g., high-interference power/signal wiring)
1681460 SACC-M12MS-5CON-PG 9-M Core: 5; Type: CON; Gland: PG9; Installation: Fixed (M) Fixed 5-core cable connection (PG9, e.g., control cabinet power distribution)
1508352 SACC-M12MS-5CON-PG 9 SH AU Core: 5; Type: CON; Gland: PG9; Feature: Shielded (SH) + AU (Australian standard) Australian-compliant shielded 5-core connection (PG9, e.g., local industrial projects)
1500774 SACC-M12MS-5CON-PG 9 Core: 5; Type: CON; Gland: PG9 Basic 5-core cable connection (PG9, e.g., general industrial wiring)

III. SACC-M12MS Nomenclature Decoding (Key to Model Understanding)

SACC-M12MS-[Core Count][Coding/Type]-[Accessory/Length]-[Special Feature]

  • Core Count: 5/6/8 → Number of signal/power cores (5=general, 6=VARAN, 8=high-density/Ethernet).
  • Coding/Type:
    • QO/Q: Protocol-specific coding (Ethernet/VA compatible);
    • SC: Standard signal coding (general-purpose);
    • PL: Pin-type contact (reliable mechanical connection);
    • CT: Special-type coding (custom equipment compatibility);
    • CON: Cable gland type (for direct cable termination).
  • Accessory:
    • PG7/PG9/PG11: Cable gland size (matches cable diameter: PG7=small, PG9=standard, PG11=large);
    • 0,5: Cable length (0.5m, pre-assembled);
    • M: Fixed installation (rigid mounting on cabinets/equipment).
  • Special Feature:
    • SH: Shielded (suppresses electromagnetic interference);
    • DN: Dual-nut locking (anti-loosening for vibration environments);
    • CM: Compact design (space-saving for narrow cabinets);
    • SKIN: Thin-profile (ultra-slim for tight spaces);
    • ETH: Ethernet-specific (optimized for industrial Ethernet);
    • VARAN: VARAN fieldbus compatibility;
    • VA: VA protocol compatibility;
    • PWR: Power-optimized (for high-current transmission);
    • DUO: Dual-configuration (versatile wiring modes);
    • AU: Compliant with Australian electrical standards.

IV. 3-Step Quick Selection Technique

Step 1: Determine Core Count Based on Transmission Needs

  • High-density signal/Ethernet: 8-core (e.g., 1421679 for Ethernet, 1543236 for 8-channel signals);
  • VARAN protocol: 6-core (only 1429130, specialized for VARAN fieldbus);
  • General signal/power: 5-core (most models, e.g., 1512555 for standard signals, 1404417 for power).

Step 2: Select Coding/Type for Protocol/Connection

  • Ethernet: QO/Q coding + ETH suffix (1421679);
  • VARAN: 6Q coding + VARAN suffix (1429130);
  • Standard signals: SC coding (1512555, 1508187);
  • Pin-type reliable connection: PL coding (1424658, 1424670);
  • Direct cable termination: CON coding + PG gland (1500774, 1404417).

Step 3: Confirm Special Features & Installation

  • High-interference environments: SH (shielded) suffix (1512555, 1694266);
  • Vibration-prone equipment: DN (dual-nut) suffix (1549793, 1424670);
  • Space constraints: CM (compact) or SKIN (thin) suffix (1426327, 1556825);
  • Power transmission: PWR suffix (1404417);
  • Regional compliance: AU suffix (1508352) for Australian projects;
  • Fixed installation: M suffix (1513334, 1681460).

V. Recommended Industry-Scenario Combinations

Industry Typical Scenario Recommended Model Combination
Factory Automation (Ethernet) PROFINET IO device connection (shielded) 1421679 (SACC-M12MS-8QO SH ETH) + 1511857 (SACC-M12MS-8CON-PG 9-SH)
Automotive Production (VARAN Protocol) Real-time sensor/actuator interconnection 1429130 (SACC-M12MS-6Q SH VARAN) + 1549793 (SACC-M12MS-5SC SH DN)
Compact Control Cabinets Slim-design 5-core power/signal wiring 1556825 (SACC-M12MS-5CON-PG9-M SKIN) + 1426327 (SACC-M12MS-5QO-0,5-CM VA)
Vibration-Prone Machinery Anti-loosening sensor wiring 1424670 (SACC-M12MS-5PL SH DN) + 1549793 (SACC-M12MS-5SC SH DN)
Australian Industrial Projects Compliance 5-core shielded wiring 1508352 (SACC-M12MS-5CON-PG 9 SH AU) + 1512555 (SACC-M12MS-5SC SH)

VI. Selection Pitfall Avoidance Guide

  1. Core count mismatch: 8-channel sensor using 5-core connector → Confirm sensor core requirements (5/6/8) to avoid signal loss.
  2. Protocol incompatibility: VARAN system using QO coding → Select 6Q VARAN model (1429130) for real-time communication compatibility.
  3. Cable gland size error: Large-diameter cable using PG7 gland → Match PG size (PG7=small, PG9=standard, PG11=large) to cable diameter.
  4. Shielding neglect: High-interference environments (inverters/motors) using non-SH models → Choose SH suffix (1512555) to suppress EMI.
  5. Vibration resistance missing: Mobile machinery using single-nut models → Select DN (dual-nut) suffix (1424670) to prevent loosening.
  6. Space constraint oversight: Compact cabinets using standard models → Opt for CM (1426327) or SKIN (1556825) suffix for slim design.
  7. Power transmission error: High-current applications using standard models → Choose PWR suffix (1404417) for power-optimized contacts.
  8. Regional compliance neglect: Australian projects using non-AU models → Select AU suffix (1508352) to meet local standards.

Conclusion: Select the Right SACC-M12MS Connector for Reliable Industrial Connectivity

The Phoenix SACC-M12MS series provides versatile, protocol-compliant solutions for 5/6/8-core M12 male connections, with special functions adapting to Ethernet, VARAN, power transmission, and harsh environments. The "core count + coding + special feature" classification simplifies selection, ensuring compatibility with industrial control systems and installation requirements. 

Phoenix SACC-M12MS Series Industrial Connectors Selection Guide (5/6/8-Core M12 Male Straight)

Created on:2025-12-05 11:27

News Dynamics

NEWS