Phoenix QPD Series Industrial Cable Entry & Wiring Systems Selection Guide
Opening: Integrated Cable Fixing, Sealing & Wiring Solutions for Industrial Enclosures
The Phoenix QPD series is a modular industrial cable entry and wiring system that combines cable gland sealing, strain relief, and terminal connection functions. It covers multiple sub-series (W/T/QSK/P/H/C/CW) with diverse core counts (2PE/3PE/4PE), wire gauges (1.5/2.5/6.0mm²), and cable outer diameter ranges (4-20mm), as well as color options (BK black/GY gray). Widely used in control cabinet cable entry, field device wiring, and multi-channel signal/power distribution, this series ensures IP65-level sealing, reliable cable fixation, and standardized wiring, adapting to harsh industrial environments. This guide structures part number-model correspondence, core parameters, and scenario recommendations to simplify selection and procurement.
I. Core Advantages: Why Choose the QPD Series?
- Integrated multi-function design: Combines cable gland (sealing/strain relief), terminal block (wiring), and mounting base (fixation) into one, eliminating the need for separate components and reducing installation steps by 40%.
- Wide cable compatibility: Supports wire gauges of 1.5/2.5/6.0mm² and cable outer diameters of 4-20mm, matching signal lines (1.5mm²), power cables (2.5/6.0mm²), and different types of industrial cables.
- Diverse installation modes: Covers wall-through (W), multi-channel terminal (T), quick-connect (QSK), panel-mount (P), multi-row (H), single/double-channel (C/CW) sub-series, adapting to cabinet walls, panels, and distribution boxes.
- Industrial-grade protection: IP65 sealing (when matched with appropriate gaskets), -40°C to +85°C operating temperature, oil/dust resistance, and anti-vibration cable fixation to ensure long-term stability.
- Standardized color coding: BK (black) for general scenarios, GY (gray) for visual differentiation of critical circuits, facilitating on-site maintenance and identification.
II. Complete Product Selection Table (Part Number + Model + Core Information)
1. W Series: Wall-Through Cable Entry (With Gland & Strain Relief)
Suitable for cable entry through cabinet walls, integrating gland sealing and terminal wiring, with optional fixed-length leads (0.5/1.0m) and fast-connect (FC) terminals.
| Part Number | Complete Model | Core Parameters | Application Scenario |
|---|---|---|---|
| 1423985 | QPD W3PE2,5 M25 DT BK | Sub-series: W; Core: 3PE; Wire Gauge: 2.5mm²; Gland: M25; Feature: DT (double terminal); Color: BK | 3-core 2.5mm² cable wall entry (e.g., control cabinet main power cable introduction) |
| 1423981 | QPD W3PE2,5 9-14 M25 FC BK | Sub-series: W; Core: 3PE; Wire Gauge: 2.5mm²; Cable OD: 9-14mm; Gland: M25; Feature: FC (fast-connect); Color: BK | 3-core 2.5mm² fast-connect cable wall entry (e.g., batch-installed sensor cable introduction) |
| 1423980 | QPD W3PE2,5 9-14 M25 0,5 BK | Sub-series: W; Core: 3PE; Wire Gauge: 2.5mm²; Cable OD: 9-14mm; Gland: M25; Lead Length: 0.5m; Color: BK | 0.5m fixed-lead 3-core cable wall entry (e.g., short-distance internal wiring after cabinet entry) |
| 1414676 | QPD W 3PE1,5 4-9 M20 1,0 BK | Sub-series: W; Core: 3PE; Wire Gauge: 1.5mm²; Cable OD: 4-9mm; Gland: M20; Lead Length: 1.0m; Color: BK | 1.0m fixed-lead 3-core signal cable wall entry (e.g., PROFINET cable introduction) |
| 1414686 | QPD W 2PE1,5 4-9 M20 FC BK | Sub-series: W; Core: 2PE; Wire Gauge: 1.5mm²; Cable OD: 4-9mm; Gland: M20; Feature: FC; Color: BK | 2-core 1.5mm² fast-connect signal cable wall entry (e.g., sensor cable introduction) |
| 1414684 | QPD W 2PE1,5 4-9 M20 0,5 BK | Sub-series: W; Core: 2PE; Wire Gauge: 1.5mm²; Cable OD: 4-9mm; Gland: M20; Lead Length: 0.5m; Color: BK | 0.5m fixed-lead 2-core signal cable wall entry (e.g., actuator feedback cable introduction) |
2. T Series: Multi-Channel Terminal Cable Entry (3-Row Installation)
Designed for multi-channel cable wiring, with 3-row mounting holes, suitable for centralized distribution of multiple cables in control cabinets.
| Part Number | Complete Model | Core Parameters | Application Scenario |
|---|---|---|---|
| 1411414 | QPD T 4PE6,0 3X9-14 BK | Sub-series: T; Core: 4PE; Wire Gauge: 6.0mm²; Mounting: 3×9-14mm holes; Color: BK | 4-core 6.0mm² high-power multi-channel wiring (e.g., main power distribution in cabinets) |
| 1414753 | QPD T 4PE1,5 3X5-10 BK | Sub-series: T; Core: 4PE; Wire Gauge: 1.5mm²; Mounting: 3×5-10mm holes; Color: BK | 4-core 1.5mm² multi-channel signal wiring (e.g., sensor array centralized connection) |
| 1414714 | QPD T 2PE1,5 3X8-13 BK | Sub-series: T; Core: 2PE; Wire Gauge: 1.5mm²; Mounting: 3×8-13mm holes; Color: BK | 2-core 1.5mm² dual-channel signal wiring (e.g., dual sensor feedback) |
| 1414712 | QPD T 2PE1,5 3X4-9 BK | Sub-series: T; Core: 2PE; Wire Gauge: 1.5mm²; Mounting: 3×4-9mm holes; Color: BK | 2-core 1.5mm² compact multi-channel wiring (e.g., narrow cabinet signal distribution) |
3. QSK Series: Quick-Connect Cable Entry (Fast Wiring)
Optimized for batch quick wiring, with FS (fast snap-in) terminals, reducing on-site installation time.
| Part Number | Complete Model | Core Parameters | Application Scenario |
|---|---|---|---|
| 1411400 | QPD QSK BK 5X6,0 FS | Sub-series: QSK; Core: 5-core; Wire Gauge: 6.0mm²; Feature: FS (fast snap-in); Color: BK | 5-core 6.0mm² high-power quick wiring (e.g., batch motor power cable connection) |
| 1414728 | QPD QSK BK 5X1,5 FS | Sub-series: QSK; Core: 5-core; Wire Gauge: 1.5mm²; Feature: FS; Color: BK | 5-core 1.5mm² multi-channel signal quick wiring (e.g., IoT sensor array connection) |
| 1414722 | QPD QSK BK 3/4X1,5 FS | Sub-series: QSK; Core: 3/4-core; Wire Gauge: 1.5mm²; Feature: FS; Color: BK | 3/4-core 1.5mm² flexible quick wiring (e.g., mixed signal/power distribution) |
| 1414758 | QPD QSK 5X1,5 | Sub-series: QSK; Core: 5-core; Wire Gauge: 1.5mm²; Feature: Basic quick connect | 5-core 1.5mm² standard quick wiring (e.g., general signal batch installation) |
4. P Series: Panel-Mount Cable Entry (Fixed to Cabinet Panels)
Panel-mounted design, suitable for front/back panel cable entry, with dual-color (BK BK) and single-color options.
| Part Number | Complete Model | Core Parameters | Application Scenario |
|---|---|---|---|
| 1039564 | QPD P 4PE6,0 9-14 TL BK | Sub-series: P; Core: 4PE; Wire Gauge: 6.0mm²; Cable OD: 9-14mm; Feature: TL (terminal lock); Color: BK | 4-core 6.0mm² panel-mounted power cable entry (e.g., cabinet front power distribution) |
| 1410386 | QPD P 4PE6,0 9-14 BK | Sub-series: P; Core: 4PE; Wire Gauge: 6.0mm²; Cable OD: 9-14mm; Color: BK | 4-core 6.0mm² standard panel cable entry (e.g., cabinet back power introduction) |
| 1410387 | QPD P 4PE6,0 12-20 BK | Sub-series: P; Core: 4PE; Wire Gauge: 6.0mm²; Cable OD: 12-20mm; Color: BK | 4-core 6.0mm² large-diameter cable panel entry (e.g., heavy-duty equipment power cable) |
| 1582637 | QPD P 3PE2,5 6-10 BK BK | Sub-series: P; Core: 3PE; Wire Gauge: 2.5mm²; Cable OD: 6-10mm; Color: Dual BK; Feature: Double sealing | 3-core 2.5mm² double-sealed panel cable entry (e.g., outdoor cabinet signal cable) |
| 1582202 | QPD P 3PE2,5 6-10 BK | Sub-series: P; Core: 3PE; Wire Gauge: 2.5mm²; Cable OD: 6-10mm; Color: BK | 3-core 2.5mm² standard panel signal cable entry (e.g., control panel sensor wiring) |
| 1414703 | QPD P 3PE1,5 4-9 BK | Sub-series: P; Core: 3PE; Wire Gauge: 1.5mm²; Cable OD: 4-9mm; Color: BK | 3-core 1.5mm² compact panel signal cable entry (e.g., narrow panel IoT module wiring) |
5. H Series: Multi-Row Cable Entry (4-Row Installation)
4-row mounting holes for high-density wiring, suitable for cabinets with multiple cables requiring centralized entry and distribution.
| Part Number | Complete Model | Core Parameters | Application Scenario |
|---|---|---|---|
| 1423995 | QPD H4X2,5 4X6-10 GY | Sub-series: H; Core: 4-core; Wire Gauge: 2.5mm²; Mounting: 4×6-10mm holes; Color: GY | 4-core 2.5mm² gray-coded high-density wiring (e.g., critical control circuit distribution) |
| 1423971 | QPD H3PE2,5 4X6-10 BK | Sub-series: H; Core: 3PE; Wire Gauge: 2.5mm²; Mounting: 4×6-10mm holes; Color: BK | 3-core 2.5mm² high-density power wiring (e.g., cabinet internal multi-device power distribution) |
| 1411422 | QPD H 4PE6,0 4X9-14 BK | Sub-series: H; Core: 4PE; Wire Gauge: 6.0mm²; Mounting: 4×9-14mm holes; Color: BK | 4-core 6.0mm² high-density high-power wiring (e.g., workshop main control cabinet power distribution) |
| 1414755 | QPD H 4PE1,5 4X5-10 BK | Sub-series: H; Core: 4PE; Wire Gauge: 1.5mm²; Mounting: 4×5-10mm holes; Color: BK | 4-core 1.5mm² high-density signal wiring (e.g., multi-sensor centralized connection) |
| 1414720 | QPD H 2PE1,5 4X8-13 BK | Sub-series: H; Core: 2PE; Wire Gauge: 1.5mm²; Mounting: 4×8-13mm holes; Color: BK | 2-core 1.5mm² dual-channel high-density wiring (e.g., dual actuator control) |
| 1414719 | QPD H 2PE1,5 4X4-9 BK | Sub-series: H; Core: 2PE; Wire Gauge: 1.5mm²; Mounting: 4×4-9mm holes; Color: BK | 2-core 1.5mm² compact high-density wiring (e.g., microcontroller peripheral sensor wiring) |
6. C/CW Series: Single/Double-Channel Cable Entry (Compact Installation)
Single (C) or double (CW) channel design, suitable for space-constrained cabinets or dedicated circuit wiring, with gray color for critical circuits.
| Part Number | Complete Model | Core Parameters | Application Scenario |
|---|---|---|---|
| 1423965 | QPD CW3PE2,5 2X6-10 GY | Sub-series: CW (double-channel); Core: 3PE; Wire Gauge: 2.5mm²; Mounting: 2×6-10mm holes; Color: GY | 3-core 2.5mm² double-channel gray-coded wiring (e.g., emergency stop circuit dedicated entry) |
| 1423991 | QPD C3PE2,5 1X6-10 BK | Sub-series: C (single-channel); Core: 3PE; Wire Gauge: 2.5mm²; Mounting: 1×6-10mm holes; Color: BK | 3-core 2.5mm² single-channel power wiring (e.g., dedicated motor power entry) |
| 1410415 | QPD C 4PE6,0 1X9-14 BK | Sub-series: C (single-channel); Core: 4PE; Wire Gauge: 6.0mm²; Mounting: 1×9-14mm holes; Color: BK | 4-core 6.0mm² single-channel high-power wiring (e.g., cabinet main power dedicated entry) |
III. QPD Series Nomenclature Decoding
QPD [Sub-series] [Core CountPE+Wire Gauge] [Cable OD/Mounting Hole Spec] [Gland/Installation Type] [Special Feature/Length] [Color]
- Sub-series:
- W = Wall-through (cable passes through cabinet walls);
- T = Multi-channel terminal (3-row mounting for centralized wiring);
- QSK = Quick-connect (FS fast snap-in terminals);
- P = Panel-mount (fixed to cabinet front/back panels);
- H = Multi-row (4-row mounting for high-density wiring);
- C = Single-channel (dedicated circuit); CW = Double-channel (dual dedicated circuits).
- Core CountPE+Wire Gauge:
- PE = Protective earth (core count includes ground wire); e.g., 3PE2.5 = 3-core (含地线) 2.5mm²; X = non-PE core count (QSK series).
- Cable OD/Mounting Hole Spec:
- Cable OD range (e.g., 4-9/6-10/9-14mm) = 适配电缆外径;
- Mounting hole spec (e.g., 3X4-9/4X6-10) = mounting hole quantity × diameter range.
- Gland/Installation Type:
- M20/M25 = cable gland thread size (matches cable OD);
- TL = terminal lock (anti-loosening); DT = double terminal (dual connection).
- Special Feature/Length:
- FC = fast-connect (quick terminal); FS = fast snap-in (QSK series);
- 0.5/1.0 = fixed lead length (meter) after cable entry.
- Color: BK = black (general); GY = gray (critical circuit identification).
IV. 3-Step Quick Selection Technique
Step 1: Select Sub-series Based on Installation Mode
- Cabinet wall cable entry: W series (e.g., 1423980, 1414676) → integrated gland + wiring.
- Centralized multi-channel wiring: T series (3-row, e.g., 1411414) or H series (4-row, e.g., 1411422) → high-density distribution.
- Batch quick wiring: QSK series (FS fast snap-in, e.g., 1414728) → reduce installation time.
- Cabinet panel mounting: P series (e.g., 1410386, 1582637) → front/back panel dedicated entry.
- Dedicated circuit (space-constrained): C (single-channel, e.g., 1423991) or CW (double-channel, e.g., 1423965) → dedicated circuit isolation.
Step 2: Match Core Count & Wire Gauge (Based on Cable Specifications)
- Signal cables (low-current): 1.5mm² (e.g., 1414676 3PE1.5, 1414712 2PE1.5) → sensor/communication lines.
- Power cables (medium-current): 2.5mm² (e.g., 1423980 3PE2.5, 1423971 H3PE2.5) → actuator/motor power lines.
- High-power cables: 6.0mm² (e.g., 1411414 T4PE6.0, 1410415 C4PE6.0) → main power distribution lines.
- Core count: 2PE (dual signal/power) → 1414684; 3PE (3-core control) → 1423980; 4PE (4-core power) → 1410386; 5-core (multi-channel) → 1414728 (QSK).
Step 3: Confirm Cable OD & Special Requirements
- Cable OD matching:
- Small OD (4-9mm): M20 gland (e.g., 1414676 W3PE1.5 4-9 M20);
- Medium OD (6-10/9-14mm): M25 gland (e.g., 1423980 W3PE2.5 9-14 M25);
- Large OD (12-20mm): P series 12-20mm spec (1410387 P4PE6.0 12-20).
- Special functions:
- Quick wiring: FC (W series, 1414686) or FS (QSK series, 1414728);
- Critical circuit identification: GY color (1423995 H4X2.5 GY, 1423965 CW3PE2.5 GY);
- Anti-loosening: TL terminal lock (1039564 P4PE6.0 TL);
- Fixed lead length: 0.5m (1423980) or 1.0m (1414676) for internal wiring.
V. Recommended Industry-Scenario Combinations
| Industry | Typical Scenario | Recommended Model Combination |
|---|---|---|
| Factory Control Cabinet (Power/Signal Entry) | Main power (6.0mm²) + signal (1.5mm²) wall entry | 1411414 (QPD T 4PE6,0 3X9-14 BK) + 1414676 (QPD W 3PE1,5 4-9 M20 1,0 BK) |
| Outdoor Cabinet (Double-Sealed Entry) | 3-core 2.5mm² signal cable panel entry (IP65) | 1582637 (QPD P 3PE2,5 6-10 BK BK) + 1423971 (QPD H3PE2,5 4X6-10 BK) |
| Batch Sensor Wiring (Quick Installation) | 5-core 1.5mm² sensor array quick connection | 1414728 (QPD QSK BK 5X1,5 FS) + 1414686 (QPD W 2PE1,5 4-9 M20 FC BK) |
| Critical Control Circuit (Gray Identification) | Emergency stop (3PE2.5) double-channel entry | 1423965 (QPD CW3PE2,5 2X6-10 GY) + 1423995 (QPD H4X2,5 4X6-10 GY) |
| Heavy-Duty Equipment (Large-Diameter Power) | 4-core 6.0mm² main power panel entry | 1410387 (QPD P 4PE6,0 12-20 BK) + 1410415 (QPD C 4PE6,0 1X9-14 BK) |
VI. Selection Pitfall Avoidance Guide
- Cable OD-gland mismatch: Large OD (12mm) using M20 gland (4-9mm) → Match gland size (M20=4-9mm, M25=9-14mm) to cable outer diameter.
- Core count/wire gauge error: 4-core power cable using 3PE model → Select 4PE (e.g., 1410386) or 4X core (QSK 1414758) for full-core wiring.
- Installation mode mismatch: Cabinet front panel entry using W (wall-through) series → Choose P series (e.g., 1582202) for panel mounting.
- Quick wiring neglect: Batch installation using standard terminals → Opt for QSK (FS) or W (FC) models (1414728, 1414686) to save time.
- Critical circuit identification missing: Emergency circuits using BK color → Select GY (1423965, 1423995) for visual differentiation.
- High-density requirement oversight: 8-channel wiring using 3-row T series → Use 4-row H series (e.g., 1411422) for more channels.
- Sealing level neglect: Outdoor applications using single-seal models → Choose P series dual BK (1582637) for enhanced IP65 sealing.
Conclusion: Select the Right QPD System for Standardized Industrial Cable Entry
The Phoenix QPD series provides integrated, modular cable entry and wiring solutions for industrial enclosures, with diverse sub-series adapting to wall-through, panel-mount, high-density, and quick-wiring scenarios. The "installation mode + core/wire gauge + cable OD" selection logic ensures compatibility with on-site cable specifications and cabinet structures, improving wiring standardization and reliability.