Phoenix QPD Series Industrial Cable Entry & Wiring Systems Selection Guide

Opening: Integrated Cable Fixing, Sealing & Wiring Solutions for Industrial Enclosures

The Phoenix QPD series is a modular industrial cable entry and wiring system that combines cable gland sealing, strain relief, and terminal connection functions. It covers multiple sub-series (W/T/QSK/P/H/C/CW) with diverse core counts (2PE/3PE/4PE), wire gauges (1.5/2.5/6.0mm²), and cable outer diameter ranges (4-20mm), as well as color options (BK black/GY gray). Widely used in control cabinet cable entry, field device wiring, and multi-channel signal/power distribution, this series ensures IP65-level sealing, reliable cable fixation, and standardized wiring, adapting to harsh industrial environments. This guide structures part number-model correspondence, core parameters, and scenario recommendations to simplify selection and procurement.


I. Core Advantages: Why Choose the QPD Series?

  1. Integrated multi-function design: Combines cable gland (sealing/strain relief), terminal block (wiring), and mounting base (fixation) into one, eliminating the need for separate components and reducing installation steps by 40%.
  2. Wide cable compatibility: Supports wire gauges of 1.5/2.5/6.0mm² and cable outer diameters of 4-20mm, matching signal lines (1.5mm²), power cables (2.5/6.0mm²), and different types of industrial cables.
  3. Diverse installation modes: Covers wall-through (W), multi-channel terminal (T), quick-connect (QSK), panel-mount (P), multi-row (H), single/double-channel (C/CW) sub-series, adapting to cabinet walls, panels, and distribution boxes.
  4. Industrial-grade protection: IP65 sealing (when matched with appropriate gaskets), -40°C to +85°C operating temperature, oil/dust resistance, and anti-vibration cable fixation to ensure long-term stability.
  5. Standardized color coding: BK (black) for general scenarios, GY (gray) for visual differentiation of critical circuits, facilitating on-site maintenance and identification.

II. Complete Product Selection Table (Part Number + Model + Core Information)

1. W Series: Wall-Through Cable Entry (With Gland & Strain Relief)

Suitable for cable entry through cabinet walls, integrating gland sealing and terminal wiring, with optional fixed-length leads (0.5/1.0m) and fast-connect (FC) terminals.

Part Number Complete Model Core Parameters Application Scenario
1423985 QPD W3PE2,5 M25 DT BK Sub-series: W; Core: 3PE; Wire Gauge: 2.5mm²; Gland: M25; Feature: DT (double terminal); Color: BK 3-core 2.5mm² cable wall entry (e.g., control cabinet main power cable introduction)
1423981 QPD W3PE2,5 9-14 M25 FC BK Sub-series: W; Core: 3PE; Wire Gauge: 2.5mm²; Cable OD: 9-14mm; Gland: M25; Feature: FC (fast-connect); Color: BK 3-core 2.5mm² fast-connect cable wall entry (e.g., batch-installed sensor cable introduction)
1423980 QPD W3PE2,5 9-14 M25 0,5 BK Sub-series: W; Core: 3PE; Wire Gauge: 2.5mm²; Cable OD: 9-14mm; Gland: M25; Lead Length: 0.5m; Color: BK 0.5m fixed-lead 3-core cable wall entry (e.g., short-distance internal wiring after cabinet entry)
1414676 QPD W 3PE1,5 4-9 M20 1,0 BK Sub-series: W; Core: 3PE; Wire Gauge: 1.5mm²; Cable OD: 4-9mm; Gland: M20; Lead Length: 1.0m; Color: BK 1.0m fixed-lead 3-core signal cable wall entry (e.g., PROFINET cable introduction)
1414686 QPD W 2PE1,5 4-9 M20 FC BK Sub-series: W; Core: 2PE; Wire Gauge: 1.5mm²; Cable OD: 4-9mm; Gland: M20; Feature: FC; Color: BK 2-core 1.5mm² fast-connect signal cable wall entry (e.g., sensor cable introduction)
1414684 QPD W 2PE1,5 4-9 M20 0,5 BK Sub-series: W; Core: 2PE; Wire Gauge: 1.5mm²; Cable OD: 4-9mm; Gland: M20; Lead Length: 0.5m; Color: BK 0.5m fixed-lead 2-core signal cable wall entry (e.g., actuator feedback cable introduction)

2. T Series: Multi-Channel Terminal Cable Entry (3-Row Installation)

Designed for multi-channel cable wiring, with 3-row mounting holes, suitable for centralized distribution of multiple cables in control cabinets.

Part Number Complete Model Core Parameters Application Scenario
1411414 QPD T 4PE6,0 3X9-14 BK Sub-series: T; Core: 4PE; Wire Gauge: 6.0mm²; Mounting: 3×9-14mm holes; Color: BK 4-core 6.0mm² high-power multi-channel wiring (e.g., main power distribution in cabinets)
1414753 QPD T 4PE1,5 3X5-10 BK Sub-series: T; Core: 4PE; Wire Gauge: 1.5mm²; Mounting: 3×5-10mm holes; Color: BK 4-core 1.5mm² multi-channel signal wiring (e.g., sensor array centralized connection)
1414714 QPD T 2PE1,5 3X8-13 BK Sub-series: T; Core: 2PE; Wire Gauge: 1.5mm²; Mounting: 3×8-13mm holes; Color: BK 2-core 1.5mm² dual-channel signal wiring (e.g., dual sensor feedback)
1414712 QPD T 2PE1,5 3X4-9 BK Sub-series: T; Core: 2PE; Wire Gauge: 1.5mm²; Mounting: 3×4-9mm holes; Color: BK 2-core 1.5mm² compact multi-channel wiring (e.g., narrow cabinet signal distribution)

3. QSK Series: Quick-Connect Cable Entry (Fast Wiring)

Optimized for batch quick wiring, with FS (fast snap-in) terminals, reducing on-site installation time.

Part Number Complete Model Core Parameters Application Scenario
1411400 QPD QSK BK 5X6,0 FS Sub-series: QSK; Core: 5-core; Wire Gauge: 6.0mm²; Feature: FS (fast snap-in); Color: BK 5-core 6.0mm² high-power quick wiring (e.g., batch motor power cable connection)
1414728 QPD QSK BK 5X1,5 FS Sub-series: QSK; Core: 5-core; Wire Gauge: 1.5mm²; Feature: FS; Color: BK 5-core 1.5mm² multi-channel signal quick wiring (e.g., IoT sensor array connection)
1414722 QPD QSK BK 3/4X1,5 FS Sub-series: QSK; Core: 3/4-core; Wire Gauge: 1.5mm²; Feature: FS; Color: BK 3/4-core 1.5mm² flexible quick wiring (e.g., mixed signal/power distribution)
1414758 QPD QSK 5X1,5 Sub-series: QSK; Core: 5-core; Wire Gauge: 1.5mm²; Feature: Basic quick connect 5-core 1.5mm² standard quick wiring (e.g., general signal batch installation)

4. P Series: Panel-Mount Cable Entry (Fixed to Cabinet Panels)

Panel-mounted design, suitable for front/back panel cable entry, with dual-color (BK BK) and single-color options.

Part Number Complete Model Core Parameters Application Scenario
1039564 QPD P 4PE6,0 9-14 TL BK Sub-series: P; Core: 4PE; Wire Gauge: 6.0mm²; Cable OD: 9-14mm; Feature: TL (terminal lock); Color: BK 4-core 6.0mm² panel-mounted power cable entry (e.g., cabinet front power distribution)
1410386 QPD P 4PE6,0 9-14 BK Sub-series: P; Core: 4PE; Wire Gauge: 6.0mm²; Cable OD: 9-14mm; Color: BK 4-core 6.0mm² standard panel cable entry (e.g., cabinet back power introduction)
1410387 QPD P 4PE6,0 12-20 BK Sub-series: P; Core: 4PE; Wire Gauge: 6.0mm²; Cable OD: 12-20mm; Color: BK 4-core 6.0mm² large-diameter cable panel entry (e.g., heavy-duty equipment power cable)
1582637 QPD P 3PE2,5 6-10 BK BK Sub-series: P; Core: 3PE; Wire Gauge: 2.5mm²; Cable OD: 6-10mm; Color: Dual BK; Feature: Double sealing 3-core 2.5mm² double-sealed panel cable entry (e.g., outdoor cabinet signal cable)
1582202 QPD P 3PE2,5 6-10 BK Sub-series: P; Core: 3PE; Wire Gauge: 2.5mm²; Cable OD: 6-10mm; Color: BK 3-core 2.5mm² standard panel signal cable entry (e.g., control panel sensor wiring)
1414703 QPD P 3PE1,5 4-9 BK Sub-series: P; Core: 3PE; Wire Gauge: 1.5mm²; Cable OD: 4-9mm; Color: BK 3-core 1.5mm² compact panel signal cable entry (e.g., narrow panel IoT module wiring)

5. H Series: Multi-Row Cable Entry (4-Row Installation)

4-row mounting holes for high-density wiring, suitable for cabinets with multiple cables requiring centralized entry and distribution.

Part Number Complete Model Core Parameters Application Scenario
1423995 QPD H4X2,5 4X6-10 GY Sub-series: H; Core: 4-core; Wire Gauge: 2.5mm²; Mounting: 4×6-10mm holes; Color: GY 4-core 2.5mm² gray-coded high-density wiring (e.g., critical control circuit distribution)
1423971 QPD H3PE2,5 4X6-10 BK Sub-series: H; Core: 3PE; Wire Gauge: 2.5mm²; Mounting: 4×6-10mm holes; Color: BK 3-core 2.5mm² high-density power wiring (e.g., cabinet internal multi-device power distribution)
1411422 QPD H 4PE6,0 4X9-14 BK Sub-series: H; Core: 4PE; Wire Gauge: 6.0mm²; Mounting: 4×9-14mm holes; Color: BK 4-core 6.0mm² high-density high-power wiring (e.g., workshop main control cabinet power distribution)
1414755 QPD H 4PE1,5 4X5-10 BK Sub-series: H; Core: 4PE; Wire Gauge: 1.5mm²; Mounting: 4×5-10mm holes; Color: BK 4-core 1.5mm² high-density signal wiring (e.g., multi-sensor centralized connection)
1414720 QPD H 2PE1,5 4X8-13 BK Sub-series: H; Core: 2PE; Wire Gauge: 1.5mm²; Mounting: 4×8-13mm holes; Color: BK 2-core 1.5mm² dual-channel high-density wiring (e.g., dual actuator control)
1414719 QPD H 2PE1,5 4X4-9 BK Sub-series: H; Core: 2PE; Wire Gauge: 1.5mm²; Mounting: 4×4-9mm holes; Color: BK 2-core 1.5mm² compact high-density wiring (e.g., microcontroller peripheral sensor wiring)

6. C/CW Series: Single/Double-Channel Cable Entry (Compact Installation)

Single (C) or double (CW) channel design, suitable for space-constrained cabinets or dedicated circuit wiring, with gray color for critical circuits.

Part Number Complete Model Core Parameters Application Scenario
1423965 QPD CW3PE2,5 2X6-10 GY Sub-series: CW (double-channel); Core: 3PE; Wire Gauge: 2.5mm²; Mounting: 2×6-10mm holes; Color: GY 3-core 2.5mm² double-channel gray-coded wiring (e.g., emergency stop circuit dedicated entry)
1423991 QPD C3PE2,5 1X6-10 BK Sub-series: C (single-channel); Core: 3PE; Wire Gauge: 2.5mm²; Mounting: 1×6-10mm holes; Color: BK 3-core 2.5mm² single-channel power wiring (e.g., dedicated motor power entry)
1410415 QPD C 4PE6,0 1X9-14 BK Sub-series: C (single-channel); Core: 4PE; Wire Gauge: 6.0mm²; Mounting: 1×9-14mm holes; Color: BK 4-core 6.0mm² single-channel high-power wiring (e.g., cabinet main power dedicated entry)

III. QPD Series Nomenclature Decoding

QPD [Sub-series] [Core CountPE+Wire Gauge] [Cable OD/Mounting Hole Spec] [Gland/Installation Type] [Special Feature/Length] [Color]

  • Sub-series:
    • W = Wall-through (cable passes through cabinet walls);
    • T = Multi-channel terminal (3-row mounting for centralized wiring);
    • QSK = Quick-connect (FS fast snap-in terminals);
    • P = Panel-mount (fixed to cabinet front/back panels);
    • H = Multi-row (4-row mounting for high-density wiring);
    • C = Single-channel (dedicated circuit); CW = Double-channel (dual dedicated circuits).
  • Core CountPE+Wire Gauge:
    • PE = Protective earth (core count includes ground wire); e.g., 3PE2.5 = 3-core (含地线) 2.5mm²; X = non-PE core count (QSK series).
  • Cable OD/Mounting Hole Spec:
    • Cable OD range (e.g., 4-9/6-10/9-14mm) = 适配电缆外径;
    • Mounting hole spec (e.g., 3X4-9/4X6-10) = mounting hole quantity × diameter range.
  • Gland/Installation Type:
    • M20/M25 = cable gland thread size (matches cable OD);
    • TL = terminal lock (anti-loosening); DT = double terminal (dual connection).
  • Special Feature/Length:
    • FC = fast-connect (quick terminal); FS = fast snap-in (QSK series);
    • 0.5/1.0 = fixed lead length (meter) after cable entry.
  • Color: BK = black (general); GY = gray (critical circuit identification).

IV. 3-Step Quick Selection Technique

Step 1: Select Sub-series Based on Installation Mode

  • Cabinet wall cable entry: W series (e.g., 1423980, 1414676) → integrated gland + wiring.
  • Centralized multi-channel wiring: T series (3-row, e.g., 1411414) or H series (4-row, e.g., 1411422) → high-density distribution.
  • Batch quick wiring: QSK series (FS fast snap-in, e.g., 1414728) → reduce installation time.
  • Cabinet panel mounting: P series (e.g., 1410386, 1582637) → front/back panel dedicated entry.
  • Dedicated circuit (space-constrained): C (single-channel, e.g., 1423991) or CW (double-channel, e.g., 1423965) → dedicated circuit isolation.

Step 2: Match Core Count & Wire Gauge (Based on Cable Specifications)

  • Signal cables (low-current): 1.5mm² (e.g., 1414676 3PE1.5, 1414712 2PE1.5) → sensor/communication lines.
  • Power cables (medium-current): 2.5mm² (e.g., 1423980 3PE2.5, 1423971 H3PE2.5) → actuator/motor power lines.
  • High-power cables: 6.0mm² (e.g., 1411414 T4PE6.0, 1410415 C4PE6.0) → main power distribution lines.
  • Core count: 2PE (dual signal/power) → 1414684; 3PE (3-core control) → 1423980; 4PE (4-core power) → 1410386; 5-core (multi-channel) → 1414728 (QSK).

Step 3: Confirm Cable OD & Special Requirements

  • Cable OD matching:
    • Small OD (4-9mm): M20 gland (e.g., 1414676 W3PE1.5 4-9 M20);
    • Medium OD (6-10/9-14mm): M25 gland (e.g., 1423980 W3PE2.5 9-14 M25);
    • Large OD (12-20mm): P series 12-20mm spec (1410387 P4PE6.0 12-20).
  • Special functions:
    • Quick wiring: FC (W series, 1414686) or FS (QSK series, 1414728);
    • Critical circuit identification: GY color (1423995 H4X2.5 GY, 1423965 CW3PE2.5 GY);
    • Anti-loosening: TL terminal lock (1039564 P4PE6.0 TL);
    • Fixed lead length: 0.5m (1423980) or 1.0m (1414676) for internal wiring.

V. Recommended Industry-Scenario Combinations

Industry Typical Scenario Recommended Model Combination
Factory Control Cabinet (Power/Signal Entry) Main power (6.0mm²) + signal (1.5mm²) wall entry 1411414 (QPD T 4PE6,0 3X9-14 BK) + 1414676 (QPD W 3PE1,5 4-9 M20 1,0 BK)
Outdoor Cabinet (Double-Sealed Entry) 3-core 2.5mm² signal cable panel entry (IP65) 1582637 (QPD P 3PE2,5 6-10 BK BK) + 1423971 (QPD H3PE2,5 4X6-10 BK)
Batch Sensor Wiring (Quick Installation) 5-core 1.5mm² sensor array quick connection 1414728 (QPD QSK BK 5X1,5 FS) + 1414686 (QPD W 2PE1,5 4-9 M20 FC BK)
Critical Control Circuit (Gray Identification) Emergency stop (3PE2.5) double-channel entry 1423965 (QPD CW3PE2,5 2X6-10 GY) + 1423995 (QPD H4X2,5 4X6-10 GY)
Heavy-Duty Equipment (Large-Diameter Power) 4-core 6.0mm² main power panel entry 1410387 (QPD P 4PE6,0 12-20 BK) + 1410415 (QPD C 4PE6,0 1X9-14 BK)

VI. Selection Pitfall Avoidance Guide

  1. Cable OD-gland mismatch: Large OD (12mm) using M20 gland (4-9mm) → Match gland size (M20=4-9mm, M25=9-14mm) to cable outer diameter.
  2. Core count/wire gauge error: 4-core power cable using 3PE model → Select 4PE (e.g., 1410386) or 4X core (QSK 1414758) for full-core wiring.
  3. Installation mode mismatch: Cabinet front panel entry using W (wall-through) series → Choose P series (e.g., 1582202) for panel mounting.
  4. Quick wiring neglect: Batch installation using standard terminals → Opt for QSK (FS) or W (FC) models (1414728, 1414686) to save time.
  5. Critical circuit identification missing: Emergency circuits using BK color → Select GY (1423965, 1423995) for visual differentiation.
  6. High-density requirement oversight: 8-channel wiring using 3-row T series → Use 4-row H series (e.g., 1411422) for more channels.
  7. Sealing level neglect: Outdoor applications using single-seal models → Choose P series dual BK (1582637) for enhanced IP65 sealing.

Conclusion: Select the Right QPD System for Standardized Industrial Cable Entry

The Phoenix QPD series provides integrated, modular cable entry and wiring solutions for industrial enclosures, with diverse sub-series adapting to wall-through, panel-mount, high-density, and quick-wiring scenarios. The "installation mode + core/wire gauge + cable OD" selection logic ensures compatibility with on-site cable specifications and cabinet structures, improving wiring standardization and reliability. 

Phoenix QPD Series Industrial Cable Entry & Wiring Systems Selection Guide